Quantum Total Light Management Suite Quantum License
SPECIFICATION SUBMITTAL Page
Job Name:
Job Number:
Model Numbers:
369778j 2 03.22.2019
Quantum
Features
Navigation
• Navigate through buildings, floors, and areas using
customized graphical floor plans
User Access
• Username and password required for user access
• Supports multiple user accounts with configurable
permission levels per user
• Supports up to 20 concurrent users and up to 10,000
user accounts
System Adjustments
•
Group areas together by type and make changes (such
as high-end tuning) to all areas in a group at one time
1
• Create quick controls to allow for simple activation of
common lighting/shading preset settings
1
Lighting Control
2
• Monitor current status of areas, scenes, and zones
• Activate lighting scenes
• Adjust lighting zone levels
• Modify lighting zone levels in area scenes
3
• Rename areas, scenes, and zones
• Adjust daylight harvesting functionality
•
Tune and trim both high-end and low-end
1
output of lights
• Configure and enable load shedding to respond to
demand response events
1
• Control individual fixtures on the graphical floorplan
4
• Control both the intensity and color of tunable white
fixtures
5
Shade Control
6
• Monitor current status of shade groups and motors
• Activate shade presets
• Adjust shade motor levels
• Modify shade motor levels in shade group presets
• Rename shade groups and presets
• Adjust Hyperion solar adaptive shade functionality
• Remotely adjust shade open/close limits
1
Occupancy
• View the real-time occupancy status of areas that
contain occupancy sensors
• Modify area occupancy functionality
• Record / analyze occupancy sensor data and view
trends using space utilization reports
7
Scheduling
• Create and edit scheduled events
• Events can be scheduled to occur at fixed times or
relative to sunrise/sunset and can be programmed to
occur once or to be reoccurring
Energy Management
8
• View energy and power usage graphs by system, floor,
or area
Reports
• System activity
• Diagnostic
• Energy savings by strategy
8
• Energy and power usage
8
Alerts
• Locate system alerts on the graphical floor plan
• Manage lamp, ballast, and driver failures of digitally
controlled fixtures
• Manage communication failures to digital devices in
the system
• Receive low-disk space alerts and manage reporting
service outages
1
• Configure which alerts are generated as well as the
frequency/timing of alert messages
1
1
Available only with Quantum System Version 3.1 and above.
2
Quantum Vue cannot control non-lighting zones or DMX 3-channel lighting zones.
3
For areas controlled by a GRAFIK Eye QS system, scene changes can be made only by using the GRAFIK Eye QS device; Quantum Vue cannot modify scenes in areas controlled
by a GRAFIK Eye QS system.
4
Requires the Fixtures on the Floorplan software license (model number QSW-RPT-FOFP). For more information, see www.lutron.com/TechnicalDocumentLibrary/
Fixtures_on_the_Floorplan_3691022.pdf
5
Available with Quantum system version 3.3 or later. Requires fixtures with built-in CCT control. For more details, see www.lutron.com/en-US/Education-Training/Pages/LCE/ColorTuning.aspx
6
For Lutron QS Wired Roller Shades only.
7
Requires the Space Utilization software license (model number QSW-RPT-SU) and the Quantum Reporting software license (model number QSW-RPT-PP-A).
8
Energy features in Quantum Vue require Quantum reporting software licenses per processor (model number QSW-RPT-PP-A).