LQSE-4S5-230-D
SPECIFICATION SUBMITTAL Page
Job Name:
Job Number:
Model Numbers:
HomeWorks QS Switching Power Module
3691061b 2 01.19.18
Specifications
Power
• 220-240V~ 50/60Hz
• Single input feed
• 16 A maximum input current
• Lightning strike protection meets ANSI/IEEE standard
C62.41 and IEC 61000-4-5. Can withstand voltage
surges up to 6000V~ and current surges up to
3000A.
• ESD-protection exceeds agency requirements per
IEC-61000-4-2
• For ungrounded delta feed applications, contact Lutron.
Regulatory Approvals
• Complies with IEC/EN 60669
• Lutron Quality Systems registered to ISO9001.2015
• CE marked
Environment
• For thermal specifications, see Mounting section
• Relative humidity: less than 90% non-condensing
• For indoor use only
Output Zone Ratings
• Each zone is rated at 5A for switching. Rated for
resistive, inductive, or capacitive lighting loads as
defined by IEC/EN 60669.
• Air gap off per output.
• No minimum load per output.
• This module is designed to control loads with ratings as
noted in the table below.
• Outputs cannot be used to control general purpose
receptacles.
Load Type
Relay Ratings
220-240 V~
Tungsten 5 A/zone, 16 A max/module
AC General Use 5 A/zone, 16 A max/module
Electric Discharge Lamp 5 A/zone, 16 A max/module
Electronic Ballast 5 A/zone, 16 A max/module
Resistive 5 A/zone, 16 A max/module
Inductive 5 A/zone, 16 A max/module
Motor
5 A (1/2 HP)/zone,
16 A max/module
• Special considerations:
– When controlling lamps, Lutron recommends
using permanently installed fixtures.
– If controlling plug-in lamps, installation must
ensure a method of preventing non-rated loads
being plugged into the unit. An example is a
dedicated receptacle with an alternate plug type.
– Controlling loads outside the parameters listed in
the specifications may damage the device and
void the warranty.
• If attempting to control general purpose receptacles,
use the appropriate third-party power pack for the
rated load.
• Run a separate neutral for each load circuit. A
common neutral connection is not recommended.
• Unit may be powered by Ground Fault Interrupter
(GFI) or Residual Current Circuit Breaker with
Overload (RCBO) protected circuit if required.
• For applications requiring higher wattage ratings, use
GRX-TVI or LQSE-4S10-D for 220-240 V~.
Programming and Compatibility Requirements
• Setup and programming of the Switching Module
is done through the HomeWorksQS programming
software.
• HomeWorksQS software version 12.0 or higher
required.
HomeWorksQS Wallstations
• HomeWorksQS wallstations can be configured to
control Switching Modules with the HomeWorksQS
programming software.
• Wallstation LED indicators display the status of
programmed lights.