SPECIFICATION SUBMITTAL Page
Job Name:
Job Number:
Model Numbers:
Radio Powr SavrTM Wireless Occupancy and Vacancy Sensor
369-480 Rev B 1 08.23.11
Wireless Ceiling Mount Sensor
Lutrons ceiling-mounted occupancy/vacancy
sensors are wireless, battery-powered passive
infrared (PIR) sensors that automatically control lights
via RF communication to compatible dimming and
switching devices. These sensors detect the heat
from people (IR radiation of 9.5 μm) moving within an
area to determine when the space is occupied. The
sensors then wirelessly transmit the appropriate
commands to the associated dimming and switching
devices to turn the lights on or off automatically. They
combine both convenience and exceptional energy
savings potential along with ease of installation.
Features
•Wirelessoccupancysensorhas3settingsavailable:
Auto-On/Auto-Off, Auto-On Low-Light/Auto-Off, and
Manual-On/Auto-Off
•Auto-OnLow-Lightfeaturewillonlyturnlightson
automatically if there is less than approximately
10 Lux (1 fc) of ambient light
•VacancyonlymodelavailabletomeetCalifornia(U.S.A.)
Title 24 requirements
•UsesClearConnect
technology
•Passiveinfraredmotiondetectionwithexclusive
LutronXCTTM Technology for fine motion detection
•360˚coveragerangesfrom324sqft(98sqm)to
676sqft(206sqm),dependingonmountingheight
•Simpleandintuitiveadjustmentsavailablefor
Timeout, Auto-On, and Activity settings
•Supportsadvancedoccupancyfeatures,suchas
dependent occupancy groups and customizable
occupied/unoccupied presets in some systems
•Multiplesensorscanbeaddedforextended
coveragerefer to product specification submittal of
receiving device to determine system limits
•Lensilluminatesduringtestmodetoverifyideal
locations
•Multipleceiling-mountmethodsavailablefordifferent
ceiling materials
•Frontaccessibletestbuttonsmakesetupeasy
•10-yearbatterylifedesign
•RoHScompliant
Models Available
•LRFX-OCR2B-P-WH
•LRF2-VCR2B-P-WH
Vacancy Only Sensor
Frequency/Channel Codes
2
=431.0–437.0MHz(US,Canada,Mexico,Brazil)
3=868.125–869.850MHz(EuropeandUAE)
4=868.125–868.475MHz(ChinaandSingapore)
5=865.5–866.5MHz(India)
6=312.3–314.8MHz(Japan)
7=433.05–434.79MHz(HongKong)
Color Code
WH
=White
Compatible RF Devices
•ForusewithLutron® products only
•CommunicatestovariouswirelessLutron® systems*
* Contact Lutron® Customer Service at
www.lutron.com for frequency/channel code
compatibility with your particular geographic region,
and for integrating with other Lutron
® lighting and
shading products.
ColorCode
Frequency/ChannelCode
Available for
ChannelCode2Only
1
SPECIFICATION SUBMITTAL Page
Job Name:
Job Number:
Model Numbers:
Radio Powr SavrTM Wireless Occupancy and Vacancy Sensor
369-480 Rev B 2 08.23.11
Specifications
Regulatory
•LutronR
QualitySystemsRegisteredto
ISO9001:2008
Standards
LRF2-
•FCCcertied
•ICcertied
•COFETELcertied
•ANATELcertied
•SUTELcertied
•MeetsCA(U.S.A.)EnergyCommissionTitle24
requirements
LRF3-
•CEMarked(EuropeanUnion)[expectedQ42011]
•TRATypeApproved(UnitedArabEmirates)
[expectedQ42011]
LRF4-
•SRRCTypeApproved(MainlandChina)[expected
Q42011]
•iDARegistered(Singapore)[expectedQ42011]
LRF5-
•WPCTypeApproved(India)
LRF6-
•
007YUUL0689
LRF7-
•FCCcertied
Power/Performance
•Operatingvoltage:3V -
•Operatingcurrent:14μAnominal
•RequiresoneCR123lithiumbattery
•10-yearbatterylifedesign
•Non-volatilememory(savedchangesarestored
during power loss)
Environment
•Temperature:32˚Fto104˚F(0˚Cto40˚C)
•Forindooruseonly
Range
•LRF2, LRF3, LRF4, LRF5, LRF7
Localloadcontrolsmustbelocatedwithin60ft
(18m)lineofsight,or30ft(9m),throughwalls,of
a sensor.
•LRF6
Local load controls must be located within 40 ft
(12.2m)lineofsightor23ft(7m),throughwalls,of
a sensor.
Sensor Coverage Test
•Frontaccessibletestbutton
•Lensilluminatesorangeinresponsetomotion
duringtestmodeandisvisiblefrom60ft(18m)
Wireless Communication Test
•Frontaccessibletestbutton
•Turnassociatedloadsonandoff
Timeout Options
•1minute*
•5minutes
•15minutes–defaultsetting
•30minutes
Auto-On Options (Occupancy Versions Only)
•“Enabled”*–SensorturnslightsONandOFF
automatically–defaultsetting.
•“LowLight”–SensorturnslightsONautomatically
onlyinlowambientlightconditions.Sensorturns
lights OFF automatically.
•“Disabled”**–LightsmustbeturnedONmanually
fromdimmingorswitchingdevice.Sensorturns
lights OFF automatically.
Activity Options
•LowActivity( )–defaultsetting
•MediumActivity( )
•HighActivity( )
* Intended for use in high-activity, briefly occupied areas only
** There is a 15-second grace period that begins when the lights are
automatically turned off, during which the lights will automatically turn
backoninresponsetomotion.Thisgraceperiodisprovidedasasafety
and convenience feature in the event the lights turn off while the room is
still occupied, so that the user does not need to manually turn the lights
backon.After15seconds,thegraceperiodexpiresandthelightsmust
be manually turned on.
2
SPECIFICATION SUBMITTAL Page
Job Name:
Job Number:
Model Numbers:
Radio Powr SavrTM Wireless Occupancy and Vacancy Sensor
369-480 Rev B 3 08.23.11
3.57 in
(90.7mm)
1.13 in
(28.7 mm)
0.887 in
(22.5 mm)
2.85 in
(72.4 mm)
Dimensions
3
SPECIFICATION SUBMITTAL Page
Job Name:
Job Number:
Model Numbers:
Radio Powr SavrTM Wireless Occupancy and Vacancy Sensor
369-480 Rev B 4 08.23.11
*12ft(3.7m)istherecommendedmaximummountingheight
Range Diagrams
18 x 18 ft (5.5 x 5.5 m)
Maximum Room Dimensions
for Complete Coverage when
mounted on an 8 ft (2.4 m) Ceiling
13 ft (4.0 m)
Radius of Coverage at Floor when
mounted on an 8 ft (2.4 m) Ceiling
15 ft
(4.6 m)
12 ft
(3.7 m)
9 ft
(2.7 m)
6 ft
(1.8 m)
3 ft
(0.9 m)
0 ft
(0 m)
3 ft
(0.9 m)
6 ft
(1.8 m)
9 ft
(2.7 m)
12 ft
(3.7 m)
15 ft
(4.6 m)
Sensor
Occupantr
Ceiling
Floor
8 ft
(2.4 m)
Ceiling
heigh
t
Radius of Coverage at Floor
Sensor Coverage Chart (for sensor mounted in center of room)
Ceiling height
Maximum room dimensions
for complete floor coverage*
324 ft
2
(30.2 m
2
)
400 ft
2
(37.2 m
2
)
484 ft
2
(44.9 m
2
)
676 ft
2
(62.4 m
2
)
8 ft (2.4 m)
9 ft (2.7 m)
10 ft (3.0 m)
12 ft (3.7 m)
18 ft x 18 ft (5.5 m × 5.5 m)
20 ft x 20 ft (6.1 m × 6.1 m)
22 ft x 22 ft (6.7 m × 6.7 m)
26 ft x 26 ft (7.9 m × 7.9 m
4
SPECIFICATION SUBMITTAL Page
Job Name:
Job Number:
Model Numbers:
Radio Powr SavrTM Wireless Occupancy and Vacancy Sensor
369-480 Rev B 5 08.23.11
Installation Overview
Sensor Placement
•Thesensor’sabilitytodetectmotionrequireslineofsightofroomoccupants.Thesensormusthavean
unobstructed view of the room. DO NOT mount behind or near tall cabinets, shelves, hanging fixtures, ceiling
fans,etc.Thesensorcannotseethroughglassobjectssuchaspatioorshowerdoors.
•Hotobjectsandmovingaircurrentscanaffectthesensorsperformance.Toensureproperoperation,thesensor
shouldbemountedatleast4ft(1.2m)awayfromHVACventsandlightbulbsthatarebelowtheceilingline.
•Thesensor’sperformancedependsonatemperaturedifferentialbetweentheambientroomtemperatureand
thatofroomoccupants.Warmerroomsmayreducethesensor’sabilitytodetectoccupants.
•LRF2, LRF3, LRF4, LRF5, LRF7: Thesensorshouldbemountedwithin60ft(18m)lineofsightor30ft(9m)
through walls of the associated dimming and switching receiving devices.
•LRF6 : Thesensorshouldbemountedwithin40ft(12.2m)lineofsightor23ft(7m)throughwalls,ofthe
associated dimming and switching receiving devices.
Mounting
•Temporarymountingisoptionaltotestsensorcoverageandwirelesscommunicationbeforepermanently
installing the sensor.
Drop Ceiling (Compressed Fiber Ceiling Tile)
•Theceilingtilemountingwireisprovidedforbothtemporaryandpermanentmountingofthesensortoceiling
tiles. It is designed to allow temporary mounting, testing, and repositioning (if necessary) of the sensor without
damaging a ceiling tile. Once the sensor’s final position has been chosen, the mounting wire should be twisted
tolockthesensorinplacepermanently.
Solid Ceiling (Drywall, Plaster, Concrete, or Wood)
•Temporarymounting:Ten(10)temporarymountingstripscanbepurchasedinthekitL-CMDPIRKITfor
temporarily mounting and testing the sensor.
•Permanentmounting:Screwsandanchors(fordrywallorplaster)providedtomountsensor.
Recess Mount
•Donotrecessmountceilingsensorinametalsurface.
•Ceilingmountclampsinternallytoceiling.Sensortwist-locksintomount,sitsushwithceiling(asshownbelow).
•Openingis3in(76.2mm)indiameter.
•Purchasedasaseparatekit:L-CRMK-WH.
Installing the Ceiling Mount Adapter
Cut mounting hole
Cut a 3 in to 3 in (76 mm to 76 mm) diameter hole to insert the ceiling
mount adapter.
Instalación del adaptador de montaje en cielo raso
Corte un orifi cio de montaje
Corte un orifi cio de 76 mm a 76 mm (3 pulg. a 3 pulg.) de diámetro para
insertar el adaptador de montaje en cielo raso.
Insert ceiling mount adapter
Insert the ceiling mount adapter into the hole and rotate brackets outwards by
turning screws.
Inserte el adaptador de montaje en cielo raso
Inserte el adaptador de montaje en cielo raso en el orifi cio y gire los soportes
hacia afuera apretando los tornillos.
1 1
2 2
3 in to 3 in
(76 mm to 76 mm)
76 mm to 76 mm
(3 in to 3 in)
Note: No need
to access top
of ceiling.
Nota: No se
requiere acceso
a la parte su-
perior del cielo
raso.
Clamp adapter to ceiling
Using a Philips screwdriver, hand-tighten the brackets, clamping the adapter to
the ceiling. Do not overtighten.
Fije el adaptador al cielo raso
Utilice un destornillador Phillips para ajustar a mano los soportes y fi jar el
adaptador al cielo raso. No ajuste demasiado.
3 3
®
Installation English
Instalación Español
5
SPECIFICATION SUBMITTAL Page
Job Name:
Job Number:
Model Numbers:
Radio Powr SavrTM Wireless Occupancy and Vacancy Sensor
369-480 Rev B 6 08.23.11
Lens Masking
Wheneverpossible,thesensorshouldbeinstalledinalocationwhereitcannoteasilyseeintoareasoutsidethe
intendedspace,suchashallwaysoradjacentrooms.Ifthissituationcannotbeavoided,portionsofthelens
maybemaskedtoblockthesensor’sviewoftheundesiredareas.Ten(10)PIRLensMaskscanbepurchased
inthekitL-CMDPIRKIT.
Lens sections
shown in white are
maskedwithlabels
Lens sections
shown in gray
have not been
masked
Lenslabelmaskingsheet
(L-CMDPIRKITsoldseparately)
6