R
Job Name:
Job Number:
Model Numbers:
Page
SPECIFICATION SUBMITTAL
rta-sci-1 01.23.07
Switch Closure Interface
Interface
RadioTouch
TM Switch Closure Interface
RTA-SCI
Coopersburg, PA 18036
RadioTouch
TM
PWR
PELV (Class 2: USA)
P/N 500-10639 © 2006 Lutron Electronics Co., Inc.
18 V
60 Hz
300 mA
910
11
12 13 14
15 16
CCI 1
CCI 2
CCI 3
CCI 4
CCI 5
CCI COM
CONF
OK
STAT
CCI LEDs
LED
A
LED
B
PWR
USA, Canada
1-800-523-9466
Mexico
1-888-235-2910
www.lutron.com
Refer to the Installers Guide for more
detailed instructions.
Référer au Guide d’installation pour plus de
renseignements détaillés.
Consulte la Guía de Instaladores para
información más detallada.
PELV (Class 2: USA)
CCI
Description
The RadioTouch switch closure interface (SCI) provides an interface
between RadioTouch controllers, timeclocks, and building
management systems (BMS). The RadioTouch SCI can communicate
with an unlimited number of RadioTouch controllers that are within 35
feet of the SCI. All controllers to which the SCI is addressed will
respond together to commands from the SCI. The SCI can accept up
to five (5) momentary dry contact closures from a timeclock or BMS
to activate four (4) preset light levels and off. Optionally, the SCI may
be configured to activate Sivoia QED
TM controllable window
treatments or AC motorized window treatments.
If an application requires the use of multiple switch closure interfaces
to perform actions affecting a large space, each SCI in the space
may be configured to issue commands sequentially to ensure the
reliability of the system.
The interface can be mounted to a standard 4 x 4 in. (120 x 120 mm)
junction box or flush-mounted on the wall, and operates from a
18 V wall plug transformer (included).
The SCI should not be used for emergency or egress lighting
applications.
1
R
Job Name:
Job Number:
Model Numbers:
Page
SPECIFICATION SUBMITTAL
rta-sci-2 01.23.07
Switch Closure Interface
Interface
R
T
A
-
S
C
I
S
wi
t
c
h
C
lo
s
u
r
e
I
n
t
e
r
f
ace
T
r
a
n
s
m
i
tt
e
r
C
oop
e
r
s
bu
r
g
, P
A
18036
R
a
dio
T
ou
c
h
TM
ST
A
T
U
S I
ND
I
CA
TO
R
OP E
RA
TIO
N
Slow Blink -Normal Operation Mode
Fast Blink - Program Mode
Very Fast Blink - Error Indication
P
ow
e
r
T
e
r
m
in
a
l
c
onn
ec
t
ion
s
a
r
e
C
l
ass
2
.
© 2000-2003 Lutron Electronics Co., Inc.
S
ee
I
n
s
t
a
ll
e
r
s
G
uid
e
f
o
r
S
ys
t
e
m
A
dd
r
ess
ing
a
nd
P
r
og
r
a
mm
ing
I
n
s
t
r
u
c
t
ion
s
RadioTouch is a trademark of Lutron Electronics
Co., Inc. This product may be covered by one or
more of the following U.S. patents: 5,248,919;
5,399,940; 5,736,965; 5,798,581; 5,838,226;
5,848,054; 5,905,442, 5,982,103
18V AC
Input
910
11
12 13 14
15 16
I
npu
t
1
I
npu
t
2
I
npu
t
3
I
npu
t
4
I
npu
t
5
I
npu
t
7
C
o
mm
on
Switch Closures
M
od
e
E
n
t
e
r
S
c
r
oll
S
t
a
t
u
s
LE
D
I
npu
t
LE
D
s
M
od
e
LE
D
A
M
od
e
LE
D
B
P
ow
e
r
LE
D
I
npu
t
6
Route control
wires through
punched holes
Plug in using
provided AC
adapter
RTA-SCI
Coopersburg, PA 18036
RadioTouch
TM
PWR
18 V
60 Hz
300 mA
910
11
12 13 14
15 16
CCI 1
CCI 2
CCI 3
CCI 4
CCI 5
CCI COM
CONF
OK
STAT
CCI LEDs
LED
A
LED
B
PWR
USA, Canada
1-800-523-9466
Mexico
1-888-235-2910
www.lutron.com
Refer to the Installers Guide for more
detailed instructions.
Référer au Guide d’installation pour plus d
e
renseignements détaillés.
Consulte la Guía de Instaladores para
información más detallada.
PELV (Class 2: USA)
CCI
4 in.
(100 mm)
2.5 in.
(17.8 mm)
7.75 in.
(197 mm)
Dimensions
Features
• Allows wireless control of lighting from timeclocks
and BMS.
• Can be addressed to control any RadioTouch
controller (RTA-RX-F, RTA-RX-F-SC, RTA-RX-F-
SC-ACM, RTA-RX-SW).
• Accepts up to five momentary dry contact
closures.
• Can be configured to control lights, Sivoia QED
controllable window treatments, and AC
motorized window treatments.
• Operates from 18 V wall outlet transformer
(included).
• Provides access to the following:
- Lights: Four (user-adjustable) preset light levels
and off
- Sivoia QED: All up, all down, and one (user-
adjustable) preset
- AC motorized window treatments: Open, stop,
and close
• Allows multiple RTA-SCI devices to be used
(maximum 64) in building sweep applications.
• Should not be used for emergency or egress
lighting applications.
Installation Mounting
Using two screws, mount the SCI to a 4 x 4 in.
(120 x 120 mm) junction box or directly to a wall
(screws and wall anchors are provided) as shown.
RTA-SCI
Coopersburg, PA 18036
RadioTouch
TM
PWR
PELV (Class 2: USA)
P/N 500-10639 © 2006 Lutron Electronics Co., Inc.
18 V
60 Hz
300 mA
910
11
12 13 14
15 16
CCI 1
CCI 2
CCI 3
CCI 4
CCI 5
CCI COM
CONF
OK
STAT
CCI LEDs
LED
A
LED
B
PWR
USA, Canada
1-800-523-9466
Mexico
1-888-235-2910
www.lutron.com
Refer to the Installers Guide for more
detailed instructions.
Référer au Guide d’installation pour plus de
renseignements détaillés.
Consulte la Guía de Instaladores para
información más detallada.
PELV (Class 2: USA)
CCI
2