SPECIFICATION SUBMITTAL Page
Job Name:
Job Number:
Model Numbers:
Stairwell Vandal-Resistant Fixture Solution
369598b 1 05.15.13
Lutron®
Stairwell Vandal-Resistant Fixture
LutronR Stairwell Vandal-Resistant Fixtures work
with LutronR Radio Powr SavrT wireless occupancy
sensors (sold separately) to save energy and lower
energy costs. These easy-to-install fluorescent
luminaires withstand high-abuse applications in public
spaces, and include a dimming ballast and wireless
control device that adjusts light levels based on
stairwell occupancy.
Features
• Universal input voltage 120/277 V~
Fully assembled fixture comes ready to install
Integral wireless control device with RF receiver
mounted inside the fixture, accessible through the
ballast cover
Integral wireless control device has occupied and
unoccupied levels that can be preset to a specific
location's code requirements
Up to nine fixtures can have the same sensor
associated to them, and up to nine sensors can be
associated to a fixture within RF range
• Integral failsafe defaults to occupied light level if
occupancy sensor is unavailable
• IEC rated rotary locking sockets (lampholders)
Tamper-resistant hardware
Polycarbonate lens prevents damage to fixture and
control device
Emergency ballast battery backup (optional)
Option
Control
Region
Lamp Type
Size
FXSWVR_PO2_-_-_SM_WH
Models Available
For a complete list of available model numbers, please
see the Ordering Guide on page 3.
Configuration:
1
®
SPECIFICATION SUBMITTAL Page
Job Name:
Job Number:
Model Numbers:
Stairwell Vandal-Resistant Fixture Solution
369598b 2 05.15.13
Lutron®
Specifications
Regulatory Approvals
• Approved to ULR and CSA standards
• Meets ASHRAE 90.1 2010 additional control (9.4.1.6)
• All models are ADA compliant
• IGCC (International Green Construction Code) Interior
Light Reduction Controls (609.3) compliant
Power / Performance
Universal input voltage 120/277 V~
Total Harmonic Distortion (THD) <20%
Power factor >0.9
Class A sound rating
Environment
50 °F to 104 °F (10 °C to 40 °C)
• Relative humidity less than 90% non-condensing
• For indoor/dry location only
RF Range (sensor to wireless control device)
• 60 ft (18 m) line of sight
• 30 ft (9 m) through normal construction
Lamps
• Use only with lamps conforming to the IEC
60081/60901 specification; Lutron recommends
Sylvania, GE, or Philips lamps for proper dimming
performance
• Lamps are not included with fixture
2 or 4 ft fixtures available in a 2 lamp configuration
Lamp options: T8, T5HE, T5HO, reduced wattage T8
• Refer to lamp manufacturer for lamp burn-in
requirements
Key Design Features
Surface mount on ceiling or wall
White baked enamel, die-formed cold rolled steel
housing and end caps. Ballast cover/pan is finished
with high-reflectance white paint
End caps have 0.625 in (16 mm) retention flanges on
3 sides for polycarbonate lens retention and maximum
security; attached with spanner-head screws
Diffuser is 0.125 in (3 mm) clear extruded
polycarbonate with side linear prisms and prismatic
bottom
• LutronR wireless control device with field-adjustable
high-end occupied level and low-end unoccupied
level with 2 available factory default settings
10% unoccupied; 50% occupied
20% unoccupied; 80% occupied
Compatible with all LutronR Radio Powr SavrT wireless
occupancy sensors
Integral FASST (Front Accessible Service Switch) at
the bottom of the wireless control device provides
100% light output for lamp burn-in or emergency mode
• IEC rated rotary locking sockets (lampholders)
Smooth, continuous flicker free dimming
2
®
SPECIFICATION SUBMITTAL Page
Job Name:
Job Number:
Model Numbers:
Stairwell Vandal-Resistant Fixture Solution
369598b 3 05.15.13
Lutron®
Product Family Fixture
Type
Size Lens Lamp Lamp Type Region Control Mounting
Type
Option Color/
Finish
FX =
Fixtures
SW =
Stairwell
VR =
Vandal
Resistant
12 =
1 x 2 ft
1
PO =
Poly-
carbonate
2 =
2 Lamp
14 =
14 W
T5HE
(2 ft Only)
U =
UL North
America
51 =
50%
Occupied
10%
Unoccupied
SM =
Surface
Mounting
XX =
None
WH =
Matte
White
14 =
1 x 4 ft
17 =
17 W
T8
(2 ft Only)
B =
BAA
Buy
America
Act
82 =
80%
Occupied
20%
Unoccupied
E1 =
T8
Emergency
Ballast
1,2
24 =
24 W
T5HO
(2 ft Only)
E3 =
T5HE
Emergency
Ballast
1,2
28 =
28 W
T5HE
(4 ft Only)
E5 =
T5HO
Emergency
Ballast
1,2
32 =
32 W
T8
(4 ft Only)
54 =
54 W
T5HO
(4 ft Only)
RW =
25, 28, 30 W
T8
Reduced
Wattage
(4 ft Only)
Ordering Guide
Select appropriate code in each column to complete model number.
Example: FXSWVR12PO214U51SMXXWH
1
Emergency ballast not available if 1 x 2 ft Size is chosen
2
Emergency ballast is determined by Lamp Type
3
®
SPECIFICATION SUBMITTAL Page
Job Name:
Job Number:
Model Numbers:
Stairwell Vandal-Resistant Fixture Solution
369598b 4 05.15.13
Lutron®
Photmetric data coming soon
Dimensions
Front View
Wireless control device (screwed inside
ballast cover; remove cover to access)
Ballast cover
Ballast (screwed inside ballast cover;
remove cover to access)
2 in (51mm) diameter knockout 0.375 in (8 mm) diameter knockouts
4.5 in (114 mm)
20 in (508 mm)
1 in (25 mm)
1 in (25 mm)
1 in (25 mm)
2 in (51 mm)
2 in (51 mm) diameter knockout
0.375 in (8 mm)
diameter knockouts
0.875 in (22 mm)
diameter
mounting hole
0.875 in (22 mm)
diameter
mounting hole
End View1 x 2 Fixture
1 x 4 Fixture
9 in (229 mm)
3.25 in (83 mm) 25 in (635 mm)
49 in (1245 mm)
4