R
Job Name:
Job Number:
Model Numbers:
Page
SPECIFICATION SUBMITTAL
ntgrx-kp-2 01.16.04
Wallstations
Slim-Button Style
®
NTGRX-KP10-__-_
9-Scene with Off and Raise/Lower
Slim Button Wallstation
Description
• Ten slim buttons select scenes.
• Mounts in standard 1-gang U.S.
wallbox.
• Status LEDs indicate which scene is
selected.
• Two large buttons dim and brighten
selected scene or turn lights full on
and off, depending on settings of
DIP switches 5 and 6.
• Works with GRAFIK Eye 3000 and
4000 Series Control Units.
• Selects scenes in just one Control Unit
or a group of up to eight Control Units.
Finish and Engraving Options
• Amber LEDs are standard. Green LEDs
are available at an additional charge.
• White, ivory, and beige matte-finish
faceplates have white buttons.
• Grey, brown, and black matte-finish
faceplates have black buttons.
• Other button color combinations are
available at an additional charge.
• Optional engraving on buttons is
recommended for ease-of-use.
LEDs
Raise (or off)Lower
(or full on)
Scene selection
buttons
Color and Finish Codes
Field Selected Functionality
DIP Switch Settings
5 6
10 slim buttons
select scenes:
1 to 9 and off
6 to 14 and off
1 to 10
6 to 15
2 large buttons:
Lower and raise selected scene
Lower and raise selected scene
Turn lights full on (to Scene 16) and off
Turn lights full on (to Scene 16) and off
1
R
Job Name:
Job Number:
Model Numbers:
Page
SPECIFICATION SUBMITTAL
ntgrx-kp-4 01.16.04
Wallstations
Slim-Button Style
®
5/16"
(8mm)
7/8"
(21mm)
4 9/16"
(116mm)
2 3/4"
(70mm)
Color and Finish Codes
Matte Finishes
Standard – Ship in 48 hours
White WH
Ivory IV
Beige BE
Gray GR
Brown BR
Black BL
Metal Finishes
Ship in 4 to 6 weeks
Bright Brass BB
Bright Chrome BC
Bright Nickel BN
Satin Brass SB
Satin Chrome SC
Satin Nickel SN
Antique Brass QB
Antique Bronze QZ
Anodized Aluminum Finishes
Ship in 4 to 6 weeks
Clear CLA
Black BLA
Brass BRA
Engraving E
Also available:
-Custom Controls
-Color Matching
Ship in 4 to 6 weeks. Pricing may
vary depending on finish.
Dimensions
Mounting
Power
Low-voltage type Class 2 (PELV).
Operating voltage: 12/24 V Direct Current.
Key Design Features
• Meets IEC 801-2. Tested to withstand 15kV
electro-static discharge without damage or
memory loss.
• Faceplate snaps on with no visible means of
attachment.
• Can be ganged to share a common
faceplate with NovaT*
®
and Vareo® Dimmers.
Counts as a “small control” for ganging.
System Communications and Capacity
• Low-voltage type Class 2 (PELV) wiring
connects Wallstations to Control Units and
other components.
• Up to 8 Control Units and up to 16 total
Wallstations and/or Control Interfaces may
be linked for a total of 24 control points.
Terminals
Accept up to two #18 AWG (1.0mm
2
) typical.
Environment
32-104°F (0-40°C). Relative humidity less
than 90% non-condensing.
Side View
Back View
1234567
4
3
2
1
DIP Switches
1-4 used to set address
5-7 used to
select function
Terminals for
Class 2 (PELV)
wiring
Specifications - KP5 & KP10
Front View
Wallbox
Wallstation
Faceplate
2
R
Job Name:
Job Number:
Model Numbers:
Page
SPECIFICATION SUBMITTAL
ntgrx-kp-5 01.16.04
Wallstations
Slim-Button Style
®
4 9/16"
(116mm)
1234567
4
3
2
1
5/16"
(8mm)
7/8"
(21mm)
4 9/16"
(116mm)
Color and FinishCodes
Matte Finishes
Standard – Ship in 48 hours
White WH
Ivory IV
Beige BE
Gray GR
Brown BR
Black BL
Metal Finishes
Ship in 4 to 6 weeks
Bright Brass BB
Bright Chrome BC
Bright Nickel BN
Satin Brass SB
Satin Chrome SC
Satin Nickel SN
Antique Brass QB
Antique Bronze QZ
Anodized Aluminum Finishes
Ship in 4 to 6 weeks
Clear CLA
Black BLA
Brass BRA
Engraving E
Also available:
-Custom Controls
-Color Matching
Ship in 4 to 6 weeks. Pricing
may vary depending on finish.
Dimensions
Power
Low-voltage type Class 2 (PELV).
Operating voltage: 12/24 V Direct Current.
Key Design Features
• Meets IEC 801-2. Tested to withstand
15kV electrostatic discharge without dam-
age or memory loss.
• Faceplate snaps on with no visible
means of attachment.
• Can be ganged to share a common
faceplate with NovaT*
® and Vareo®
Dimmers. Counts as a “small control”
for ganging.
System Communications and Capacity
• Low-voltage type Class 2 (PELV) wiring
connects Wallstations to Control Units
and other components.
• Up to 8 Control Units and up to 16 total
Wallstations and/or Control Interfaces may
be linked for a total of 24 control points.
Terminals
Accept up to two #18 AWG (1.0mm
2
) typ-
ical.
Environment
32-104°F (0-40°C). Relative humidity less
than 90% non-condensing.
Side View
Back View
Mounting
Wallbox
Wallstation
Faceplate
DIP Switches
1-4 used to set address
5-7 used to
select function
Terminals for
Class 2 (PELV)
wiring
Specifications - KP15
Front View
3