Maestro Sensor
369666f 1 09.05.19
®
SPECIFICATION SUBMITTAL Page
Job Name:
Job Number:
Model Numbers:
Switch with Occupancy / Vacancy Sensor
Maestro sensor switch
The Lutron Maestro occupancy sensor switch combines a
Maestro switch with a passive infrared occupancy or vacancy
sensor. The sensor detects the heat from occupants moving
within an area to determine whether the space is occupied.
Based on the feedback from the sensor, the occupancy sensor
switch will adjust the load accordingly.
Features
Passive infrared sensors with exclusive Lutron XCT Technology
for fine motion detection
180° sensor field-of-view
Up to 30 ft x 30 ft (9 m x 9 m) [900 ft
2
(81 m
2
)] major motion
coverage and 20 ft x 20 ft (6 m x 6 m) [400 ft
2
(36m
2
)] minor
motion coverage
Occupancy version can be set to Auto-ON / Auto-OFF or
Manual-ON / Auto-OFF
Vacancy version available to meet CA Title 24 requirements
Adjustable timeout (1, 5, 15, or 30 minutes) and high/low
sensitivity adjustment
Load types: incandescent, halogen, ELV, MLV, CFL, LED,
magnetic fluorescent, electronic fluorescent, and fan.
Note: "XX" in model number represents color/finish code.
Models available
MS-OPS2-XX
1
MS-OPS2H-XX-C
2
MS-OPS5M-XX
3
MS-OPS5MH-XX-C
2
MS-OPS6M2-DV-XX
MS-OPS6M2U-DV-XX
UMS-OPS6M2-DV-XX
MS-VPS2-XX
1
MS-VPS5M-XX
3
MS-VPS6M2-DV-XX
MS-VPS6M2U-DV-XX
UMS-VPS6M2-DV-XX
MS-OPS2
MS-OPS2H-XX-C
MS-OPS5M
MS-OPS5MH-XX-C
MS-OPS6M2-DV
MS-OPS6M2U-DV
UMS-OPS6M2-DV
MS-VPS2
MS-VPS5M
MS-VPS6M2-DV
MS-VPS6M2U-DV
UMS-VPS6M2-DV
1
For clamshell packaging, add an "H" after the "2". Available in AL, IV, LA, and WH.
2
Clamshell packaged product for Canada. Available in AL, IV, LA, and WH.
3
For clamshell packaging, add an "H" after the "M". Available in AL, IV, LA, and WH.
1
Maestro Sensor
369666f 2 09.05.19
®
SPECIFICATION SUBMITTAL Page
Job Name:
Job Number:
Model Numbers:
Switch with Occupancy / Vacancy Sensor
Specifications
Regulatory Approvals
UL
® Listed to U.S. and Canadian safety
requirements.
NOM Certification (MS- models only).
Power
120 V~ 50 / 60 Hz*
120 – 277 V~ 50 / 60 Hz*
Key Design Features
All lighting loads
Crush/tamper resistant lens
Smart ambient light detection
Adaptive switching algorithm for extended relay life
XCT Technology for fine motion detection
Lutron patented Softswitch
Environment
Ambient operating temperature: 32 °F to 104 °F
(0 °C to 40 °C), 0% 90% humidity, non-condensing.
Indoor use only.
Warranty
5-Year Limited Warranty. For additional Warranty
information, please visit
www.lutron.com/TechnicalDocumentLibrary/Sensor_
Warranty.pdf
Additional Information
When using MS-OPS2, MS-OPS5M,
MS-OPS6M2-DV, MS-VPS2, MS-VPS5M, or
MS-VPS6M2-DV on GFI-controlled circuits, please
see Lutron P/N 048440 on www.lutron.com
For Maestro Occupancy sensing dimmer models,
please see Lutron P/N 369270 on www.lutron.com
For use with MA-AS, MSC-AS, MA-AS-277, or
MSC-AS-277 to control the load from more than two
locations, please see Lutron P/N 048435 on
www.lutron.com
For more information, please see
www.lutron.com/occvacsensors
Lutron Customer Assistance: 1.844.LUTRON1
Advanced Features
Switching
Standard zero cross—maximizes relay life by
switching at the point of minimum energy on the AC
power curve
Adaptive zero cross—maximizes relay life by
switching at the point of minimum energy on the AC
power curve. Actively adapts to variations in relay
timing
Lutron Patented Softswitch circuit—eliminates arcing
at mechanical contacts when loads are switched.
Extends relay life to an average of 1,000,000 cycles
(on/off) for resistive, capacitive, or inductive sources
XCT Technology
Advanced sensing technology for fine motion
detection ensures that the lights stay on while the
room is occupied, and that the sensor does not turn
on falsely when there is no occupancy in the room.
For more information, see
www.lutron.com/TechnicalDocumentLibrary/
white%20paper%20XCT%204-23-09%20B.pdf
* Maximum current ratings for individual models are provided in the Selection Matrix on page 4.
2
Maestro Sensor
369666f 3 09.05.19
®
SPECIFICATION SUBMITTAL Page
Job Name:
Job Number:
Model Numbers:
Switch with Occupancy / Vacancy Sensor
Custom Settings
Ambient Light Detection
Lights turn on only if natural light in room is low.
Smart—Ambient light threshold adjusts precisely to
the user’s preference.
Instructions: If switch turns on when there is enough natural light, or if
switch does not turn on when there is not enough natural light, press
the large button within 5 seconds of entering the room. Over time, this
interaction will “teach” the switch your preferred setting.
Presets—high, medium, low, and disabled.
Sensor Operation
Occupancy/Vacancy: Auto-ON / Auto-OFF or
Manual-ON / Auto-OFF
Vacancy only: Manual-ON / Auto-OFF only
Timeout Options
(See Additional Features on page 5 for default settings)
1 Minute
5 Minutes
15 Minutes
30 Minutes
Sensitivity Options
High sensitivity (default)
Low sensitivity
Auto-ON Options
(MS-OPS and UMS-OPS only)
Occupancy (default): Auto-ON / Auto-OFF
Vacancy*: Manual-ON / Auto-OFF
Low Light: Lights turn on only if needed (if ambient
light is below threshold)
* There is a 15-second grace period that begins when the lights are
automatically turned off, during which the lights will automatically turn
back on in response to motion. This grace period is provided as a safety
and convenience feature in the event that the lights turn off while the
room is still occupied, so that the user does not need to manually turn
the lights back on. After 15 seconds, the grace period expires and the
lights must be manually turned on.
Manual Off-While-Occupied Options
(MS-OPS and UMS-OPS only see Additional Features on page 5 for
default setting)
• Enabled
– When the occupancy sensor switch is manually
turned off, the occupancy sensor switch will not
turn the lights back on automatically while the
room is occupied.
– Once the room is vacated, the Auto-ON feature
returns to normal operation after the timeout
period has expired.
– This may be the preference in conference rooms
or classrooms while viewing presentations. This
feature requires motion to keep the lights off.
• Disabled
– When the occupancy sensor switch is manually
turned off, the Auto-ON feature will return to
normal operation after 25 seconds.
– This may be the preference if the user always
wants the lights to turn on upon entering and the
lights to turn off when the room is vacant.
3
Maestro Sensor
369666f 4 09.05.19
®
SPECIFICATION SUBMITTAL Page
Job Name:
Job Number:
Model Numbers:
Switch with Occupancy / Vacancy Sensor
Selection Matrix
1
XX in model number represents color/finish code.
2
Occupancy sensors can be configured as Auto-ON / Auto-OFF or Manual-ON / Auto-OFF.
Vacancy sensors are configured as Manual-ON / Auto-OFF only.
3
Standard mechanical 3-way switch cannot be combined with companion switch.
4
Companion switch MA-AS, MSC-AS, MA-AS-277, or MSC-AS-277 is required for multi-location installations (more than two locations controlling the
same lighting circuit). Up to nine companion switches may be connected.
5
BAA-compliant models.
* Note: Neutral is optional only for retrofit or replacement applications when ground connection is available. Connect green-sleeve wire
to ground when a neutral connection is not available. When a neutral connection is available, remove the green sleeve and connect the
white wire to neutral. Please note that a ground or neutral wire is required for product to function. If neither wire is present, consult a
licensed electrician.
Vacancy only
2
(Title 24 compliant)
Single-pole only
Single-pole / 3-way
capability
Works with standard mechanical 3-way switch
3
Works with companion switch
3, 4
All lighting loads (120 V~ only)
Max current rating
All lighting loads (120 277 V~ only)
Fan (120 V~)
Light + Fan (120 V~)
Neutral wire optional
*
Off-state power
Minimum load required
Relevant wiring diagram
Model Number
1
MS-OPS2-XX
2 A
1
MS-OPS2H-XX-C
2 A
1
MS-OPS5M-XX
5 A 3 A 3 A
2, 3, 5
MS-OPS5MH-XX-C
5 A 3 A 3 A
2, 3, 5
MS-OPS6M2-DV-XX
6 A 3 A 3 A
2 – 6
MS-OPS6M2U-DV-XX
6 A 3 A 3 A
7 – 11
UMS-OPS6M2-DV-XX
5
6 A 3 A 3 A
2 – 6
MS-VPS2-XX
2 A
1
MS-VPS5M-XX
5 A 3 A 3 A
2, 3, 5
MS-VPS6M2-DV-XX
6 A 3 A 3 A
2 – 6
MS-VPS6M2U-DV-XX
6 A 3 A 3 A
7 – 11
UMS-VPS6M2-DV-XX
5
6 A 3 A 3 A
2 – 6
4
Maestro Sensor
369666f 5 09.05.19
®
SPECIFICATION SUBMITTAL Page
Job Name:
Job Number:
Model Numbers:
Switch with Occupancy / Vacancy Sensor
Crush/tamper-resistant lens
Ambient light detection
Switching
XCT technology
Manual off-while-occupied default setting
Default timeout (minutes)
Model Number
1
MS-OPS2-XX
Smart Adaptive
Disabled 5
MS-OPS2H-XX-C
Smart Adaptive
Disabled 5
MS-OPS5M-XX
Smart Adaptive
Disabled 5
MS-OPS5MH-XX-C
Smart Adaptive
Disabled 5
MS-OPS6M2-DV-XX
Smart Adaptive
Enabled 15
MS-OPS6M2U-DV-XX
Smart Adaptive
Enabled 15
UMS-OPS6M2-DV-XX Presets Adaptive
Enabled 5
MS-VPS2-XX
Smart Adaptive
5
MS-VPS5M-XX
Smart Adaptive
5
MS-VPS6M2-DV-XX
Smart Adaptive
15
MS-VPS6M2U-DV-XX
Smart Adaptive
15
UMS-VPS6M2-DV-XX Presets Adaptive
5
Additional Features
1
XX in model number represents color/finish code.
5
Maestro Sensor
369666f 6 09.05.19
®
SPECIFICATION SUBMITTAL Page
Job Name:
Job Number:
Model Numbers:
Switch with Occupancy / Vacancy Sensor
5 ft
(1.5 m)
10 ft
(3 m)
15 ft
(4.5 m)
20 ft
(6 m)
25 ft
(7.5 m)
30 ft
(9 m)
Horizontal Beam Diagram
Vertical Beam Diagram
4 ft
(1.2 m)
00 10 ft
(3 m)
15 ft
(4.5 m)
20 ft
(6 m)
25 ft
(7.5 m)
30 ft
(9 m)
NEMA WD7 Coverage
5 ft
(1.5 m)
5 ft
(1.5 m)
0
10 ft
(3 m)
10 ft
(3 m)
15 ft
(4.5 m)
15 ft
(4.5 m)
5 ft
(1.5 m)
Major motion coverage: 900 ft
2
(81 m
2
)
Minor motion coverage: 400 ft
2
(36 m
2
)
Placement and Operation
The ability of the occupancy sensor switch to detect motion requires line-of-sight of room occupants. The
occupancy sensor switch must have an unobstructed view of the room.
Hot objects and moving air currents can affect the performance of the occupancy sensor switch.
The performance of the occupancy sensor switch depends on a temperature differential between the ambient
room temperature and that of room occupants. Warmer rooms may reduce the ability of the occupancy sensor
switch to detect occupants.
Definitions
Major motion: movement of a person entering or passing through an area.
Minor motion: movement of a person occupying an area and engaging in small activities (e.g., reaching for a
telephone, turning the pages of a book, opening a file folder, picking up a coffee cup).
15 ft
(4.5 m)
10 ft
(3 m)
5 ft
(1.5 m)
0
5 ft
(1.5 m)
10 ft
(3 m)
15 ft
(4.5 m)
6
Maestro Sensor
369666f 7 09.05.19
®
SPECIFICATION SUBMITTAL Page
Job Name:
Job Number:
Model Numbers:
Switch with Occupancy / Vacancy Sensor
Ganging
When ganging with other controls in the same wallbox, remove inside fins (UMS-OPS6M-DV and
UMS-VPS6M-DV only).
Dimensions
Measurements shown as: in (mm).
Front View
Side View
4
11
16
(119)
2
15
16
(75)
1
1
8
(30)
5/16 (8)
1/8 (3)
Do NOT remove outside fins on end-of-gang controls
Each control has
inside fins removed
Middle of Gang control has
all fins removed
7
Maestro Sensor
369666f 8 09.05.19
®
SPECIFICATION SUBMITTAL Page
Job Name:
Job Number:
Model Numbers:
Switch with Occupancy / Vacancy Sensor
Operation
MS-OPS2
MS-OPS5M
MS-OPS6M2-DV
MS-OPS6M2U-DV
UMS-OPS6M2-DV
MS-VPS2
MS-VPS5M
MS-VPS6M2-DV
MS-VPS6M2U-DV
UMS-VPS6M2-DV
Sensor Lens
Tapswitch
Tap on / off
Sensor LED (behind lens)
Pulses during configuration
of custom settings and in the
Test mode.
Mounting
Wallbox Occupancy sensor switch Wallplate Adapter / Wallplate
(sold separately)
Mounting screws Adapter mounting screws
Black
Blue
**
Bare
* White wire with
green sleeve
* Note: For MS-OPS6M2U-DV-XX and MS-VPS6M2U-DV-XX wire will be green wire covered by
white sleeve.
* * Note:
Blue wire not on models: MS-OPS2, MS- VPS2.
8
Maestro Sensor
369666f 9 09.05.19
®
SPECIFICATION SUBMITTAL Page
Job Name:
Job Number:
Model Numbers:
Switch with Occupancy / Vacancy Sensor
Continued on next page...
Wiring Diagrams
Single Location Installation (120 V~)
-OPS2 and -VPS2
Wiring Diagram 1- with Neutral
Occupancy
sensor switch
120 V~
50 / 60 Hz
White
Ground
Hot / Live
Neutral
Load
Bare
Black Black
Single Location Installation (120 V~)
1
-OPS5M, -OPS6M2-DV, -VPS5M, -VPS6M2-DV
Wiring Diagram 2 - with Neutral
120 V~
50 / 60 Hz
White
Ground
Hot / Live
Neutral
Load
Blue
1
Bare
Black Black
Occupancy
sensor switch
Single Location Installation (120 V~)
-OPS2 and -VPS2
Wiring Diagram 1- without Neutral
Occupancy
sensor switch
120 V~
50 / 60 Hz
Green-sleeved wire
Ground
Hot / Live
Neutral
Load
Bare
Black Black
1
When using controls in single location installations, tighten the blue terminal or cap blue wire. Do not connect the blue terminal / wire to any other
wire or to ground.
2
Only one occupancy sensor switch can be used per multi-location circuit.
3
A single standard mechanical 3-way switch or up to 9 companion switches may be connected to most occupancy sensor switches.
Standard mechanical 3-way switch cannot be combined with companion switch. Total blue terminal wire length may be up to 150ft (46m).
Single Location Installation (120 V~)
1
-OPS5M, -OPS6M2-DV, -VPS5M, -VPS6M2-DV
Wiring Diagram 2 - without Neutral
120 V~
50 / 60 Hz
Green-sleeved wire
Ground
Hot / Live
Neutral
Load
Blue
1
Bare
Black Black
Occupancy
sensor switch
Note: Connect green-sleeved wire to ground only in retrofit and
replacement applications.
Note: When a neutral connection is available, remove the green
sleeve and connect the white wire to neutral.
Note: Connect green-sleeved wire to ground only in retrofit and
replacement applications.
Note: When a neutral connection is available, remove the green
sleeve and connect the white wire to neutral.
9
Maestro Sensor
369666f 10 09.05.19
®
SPECIFICATION SUBMITTAL Page
Job Name:
Job Number:
Model Numbers:
Switch with Occupancy / Vacancy Sensor
1
When using controls in single location installations, tighten the blue terminal or cap blue wire. Do not connect the blue terminal / wire to any other
wire or to ground.
2
Only one occupancy sensor switch can be used per multi-location circuit.
3
A single standard mechanical 3-way switch or up to 9 companion switches may be connected to most occupancy sensor switches.
Standard mechanical 3-way switch cannot be combined with companion switch. Total blue terminal wire length may be up to 150ft (46m).
Wiring Diagrams (continued)
Note: When a neutral connection is available, remove the green sleeve and connect the white wire to neutral.
Continued on next page...
Black
Blue
White
Ground
Green
screw
Ground
120 V~
50 / 60 Hz
Hot / Live
Neutral
Load
Standard
mechanical switch
Black
Jumper wire
Bare
Different color
screw (Common)
OR
Black
Blue
Ground
White
Ground
120 V~
50 / 60 Hz
Hot / Live
Neutral
Load
Standard
mechanical switch
Black
Jumper wire
Bare
Different color
screw (Common)
Green
screw
3-way Installation with Standard Mechanical Switch (120 V~)
2, 3
-OPS5M, -OPS6M2-DV, -VPS5M, -VPS6M2-DV
Wiring Diagram 3 - with Neutral
Occupancy
sensor switch
Occupancy
sensor switch
10
Maestro Sensor
369666f 11 09.05.19
®
SPECIFICATION SUBMITTAL Page
Job Name:
Job Number:
Model Numbers:
Switch with Occupancy / Vacancy Sensor
Wiring Diagrams (continued)
1
When using controls in single location installations, tighten the blue terminal or cap blue wire. Do not connect the blue terminal / wire to any other
wire or to ground.
2
Only one occupancy sensor switch can be used per multi-location circuit.
3
A single standard mechanical 3-way switch or up to 9 companion switches may be connected to most occupancy sensor switches.
Standard mechanical 3-way switch cannot be combined with companion switch. Total blue terminal wire length may be up to 150ft (46m).
Note: Connect green-sleeved wire to ground only in retrofit and replacement applications.
Continued on next page...
Black
Blue
Green-sleeved wire
Ground
Green
screw
Ground
120 V~
50 / 60 Hz
Hot/Live
Neutral
Load
Standard
mechanical switch
Black
Jumper wire
Bare
Different color
screw (Common)
OR
Black
Blue
Ground
Green-sleeved wire
Ground
120 V~
50 / 60 Hz
Hot/Live
Neutral
Load
Standard
mechanical switch
Black
Jumper wire
Bare
Different color
screw (Common)
Green
screw
3-way Installation with Standard Mechanical Switch (120 V~)
2, 3
-OPS5M, -OPS6M2-DV, -VPS5M, -VPS6M2-DV
Wiring Diagram 3 - without Neutral
Occupancy
sensor switch
Occupancy
sensor switch
11
Maestro Sensor
369666f 12 09.05.19
®
SPECIFICATION SUBMITTAL Page
Job Name:
Job Number:
Model Numbers:
Switch with Occupancy / Vacancy Sensor
Wiring Diagrams (continued)
1
A single standard mechanical 3-way switch or up to 9 companion switches may be connected to most occupancy sensor switches.
Standard mechanical 3-way switch cannot be combined with companion switch. Total blue terminal wire length may be up to 150ft (46m).
2
Only one occupancy sensor switch can be used per multi-location circuit.
3
Fan load applies to 120 V~ only (not for 277 V~).
4
Occupancy sensor switch can be installed in any location.
Continued on next page...
Wiring Diagram 4 - with Neutral
3-way Installation with Standard Mechanical Switch (277 V~)
1, 2, 3
-OPS6M2-DV, -VPS6M2-DV
Black
Blue
White
Ground
Green
screw
Ground
120 V~
50 / 60 Hz
Hot/Live
Neutral
Load
Standard
mechanical switch
Black
Jumper wire
Bare
Different color
screw (Common)
OR
Black
Blue
Ground
White
Ground
120 V~
50 / 60 Hz
Hot/Live
Neutral
Load
Standard
mechanical switch
Black
Jumper wire
Bare
Different color
screw (Common)
Green
screw
Note: When a neutral connection is available, remove the green sleeve and connect the white wire to neutral.
Occupancy
sensor switch
Occupancy
sensor switch
12
Maestro Sensor
369666f 13 09.05.19
®
SPECIFICATION SUBMITTAL Page
Job Name:
Job Number:
Model Numbers:
Switch with Occupancy / Vacancy Sensor
Wiring Diagrams (continued)
Wiring Diagram 4 - without Neutral
Note: Connect green-sleeved wire to ground only in retrofit and replacement applications.
1
A single standard mechanical 3-way switch or up to 9 companion switches may be connected to most occupancy sensor switches.
Standard mechanical 3-way switch cannot be combined with companion switch. Total blue terminal wire length may be up to 150ft (46m).
2
Only one occupancy sensor switch can be used per multi-location circuit.
3
Fan load applies to 120 V~ only (not for 277 V~).
4
Occupancy sensor switch can be installed in any location.
Continued on next page...
3-way Installation with Standard Mechanical Switch (277 V~)
1, 2, 3
-OPS6M2-DV, -VPS6M2-DV
Note: When neutral connection is available, remove green sleeve and connect
white wire to neutral.
Black
Blue
Green-sleeved wire
Ground
Occupancy
sensor switch
Green screw
Ground
277 V~
50 / 60 Hz
Hot / Live
Neutral
Load
Standard
mechanical switch
Black
Jumper wire
Bare
Different color screw
(Common)
OR
Black
Blue
Ground
Occupancy
sensor switch
Green-sleeved wire
Ground
277 V~
50 / 60 Hz
Hot / Live
Neutral
Load
Standard
mechanical switch
Black
Jumper wire
Bare
Different color screw
(Common)
Green screw
13
Maestro Sensor
369666f 14 09.05.19
®
SPECIFICATION SUBMITTAL Page
Job Name:
Job Number:
Model Numbers:
Switch with Occupancy / Vacancy Sensor
Wiring Diagram 5 - with Neutral
Multi-Location Installation (120 V~)
1, 2, 4
-OPS5M, -OPS6M2-DV, -VPS5M, -VPS6M2-DV with MA-AS or MSC-AS
Blue
White
Ground
Occupancy
sensor switch
4
Black
Ground
120 V~
50 / 60 Hz
Brass
BrassBlack
Blue Blue
Green
Green
Ground
Hot / Live
Neutral
Load
MA-AS or
MSC-AS
MA-AS or
MSC-AS
Bare
Black Black
Wiring Diagrams (continued)
Wiring Diagram 5 - without Neutral
Multi-Location Installation (120 V~)
1, 2, 4
-OPS5M, -OPS6M2-DV, -VPS5M, -VPS6M2-DV with MA-AS or MSC-AS
Blue
Green-
sleeved
wire
Ground
Occupancy
sensor switch
4
Black
Ground
120 V~
50 / 60 Hz
Brass
BrassBlack
Blue Blue
Green
Green
Ground
Hot / Live
Neutral
Load
MA-AS or
MSC-AS
MA-AS or
MSC-AS
Bare
Black Black
1
A single standard mechanical 3-way switch or up to 9 companion switches may be connected to most occupancy sensor switches.
Standard mechanical 3-way switch cannot be combined with companion switch. Total blue terminal wire length may be up to 150ft (46m).
2
Only one occupancy sensor switch can be used per multi-location circuit.
3
Fan load applies to 120 V~ only (not for 277 V~).
4
Occupancy sensor switch can be installed in any location.
Note: Connect green-sleeved wire to ground only in retrofit and replacement applications.
Note: When a neutral connection is available, remove the green sleeve and connect the white wire to neutral.
Continued on next page...
14
Maestro Sensor
369666f 15 09.05.19
®
SPECIFICATION SUBMITTAL Page
Job Name:
Job Number:
Model Numbers:
Switch with Occupancy / Vacancy Sensor
Wiring Diagrams (continued)
Wiring Diagram 6 - with Neutral
Multi-Location Installation (277 V~)
1, 2, 3, 4
-OPS6M2-DV, -VPS6M2-DV with MA-AS-277 or MSC-AS-277
Occupancy
sensor switch
3
Black
Blue
White
Ground
Black
Blue
Green
Ground
277 V~
50 / 60 Hz
Black
Blue
Green
Ground
Hot / Live
Neutral
Load
RedRed
Bare
Black
MA-AS-277 or
MSC-AS-277
MA-AS-277 or
MSC-AS-277
Continued on next page...
Wiring Diagram 6 - without Neutral
Multi-Location Installation (277 V~)
1, 2, 3, 4
-OPS6M2-DV, -VPS6M2-DV with MA-AS-277 or MSC-AS-277
Occupancy
sensor switch
3
Black
Blue
Green-
sleeved
wire
Ground
Black
Blue
Green
Ground
277 V~
50 / 60 Hz
Black
Blue
Green
Ground
Hot / Live
Neutral
Load
RedRed
Bare
Black
MA-AS-277 or
MSC-AS-277
MA-AS-277 or
MSC-AS-277
1
A single standard mechanical 3-way switch or up to 9 companion switches may be connected to most occupancy sensor switches.
Standard mechanical 3-way switch cannot be combined with companion switch. Total blue terminal wire length may be up to 150ft (46m).
2
Only one occupancy sensor switch can be used per multi-location circuit.
3
Fan load applies to 120 V~ only (not for 277 V~).
4
Occupancy sensor switch can be installed in any location.
Note: When a neutral connection is available, remove the green sleeve and connect the white wire to neutral.
Note: Connect green-sleeved wire to ground only in retrofit and replacement applications.
15
Maestro Sensor
369666f 16 09.05.19
®
SPECIFICATION SUBMITTAL Page
Job Name:
Job Number:
Model Numbers:
Switch with Occupancy / Vacancy Sensor
Single Location Installation (120-277 V~)
1, 2
-OPS6M2U-DV, -VPS6M2U-DV
Wiring Diagram 7 - with Neutral
Occupancy
sensor switch
120-277 V~ 50 / 60 Hz
White-
sleeved wire
Ground
Hot/Live
Neutral
Load
Blue
1
Bare
Black Black
1
When using controls in single location installations, tighten the blue terminal or cap blue wire. Do NOT connect the blue terminal / wire to any other
wire or to ground.
2
Fan load applies to 120 V~ only (not for 277 V~).
3
Only one occupancy sensor switch can be used per multi-location circuit.
4
A single standard mechanical 3-way switch or up to 9 companion switches may be connected to most occupancy sensor switches.
Standard mechanical 3-way switch cannot be combined with companion switch. Total blue terminal wire length may be up to 150ft (46m).
Wiring Diagrams (continued)
Continued on next page...
Single Location Installation (120-277 V~)
1, 2
-OPS6M2U-DV, -VPS6M2U-DV
Wiring Diagram 7 - without Neutral
Occupancy
sensor switch
120-277 V~ 50 / 60 Hz
Green
Ground
Hot / Live
Neutral
Load
Blue
1
Bare
Black Black
Note: Remove white sleeve and connect green wire to ground only in retrofit and replacement applications.
Note: When a neutral connection is available, connect the white-sleeved wire to neutral.
16
Maestro Sensor
369666f 17 09.05.19
®
SPECIFICATION SUBMITTAL Page
Job Name:
Job Number:
Model Numbers:
Switch with Occupancy / Vacancy Sensor
3-way Installation with Standard Mechanical Switch (120 V~)
3, 4
-OPS6M2U-DV, -VPS6M2U-DV
Wiring Diagram 8 - with Neutral
OR
Black
Blue
Ground
Occupancy
sensor switch
White-sleeved
wire
Ground
120 V~
50 / 60 Hz
Hot / Live
Neutral
Load
Standard
mechanical switch
Black
Jumper wire
Bare
Different color
screw (Common)
Green
screw
Black
Blue
White-sleeved wire
Ground
Occupancy
sensor switch
Ground
120 V~
50 / 60 Hz
Hot / Live
Neutral
Load
Standard
mechanical switch
Black
Jumper wire
Bare
Different color
screw (Common)
Green
screw
Wiring Diagrams (continued)
Note: When a neutral connection is available, connect the white-sleeved wire to neutral.
1
When using controls in single location installations, tighten the blue terminal or cap blue wire. Do NOT connect the blue terminal / wire to any other
wire or to ground.
2
Fan load applies to 120 V~ only (not for 277 V~).
3
Only one occupancy sensor switch can be used per multi-location circuit.
4
A single standard mechanical 3-way switch or up to 9 companion switches may be connected to most occupancy sensor switches.
Standard mechanical 3-way switch cannot be combined with companion switch. Total blue terminal wire length may be up to 150ft (46m).
Continued on next page...
17
Maestro Sensor
369666f 18 09.05.19
®
SPECIFICATION SUBMITTAL Page
Job Name:
Job Number:
Model Numbers:
Switch with Occupancy / Vacancy Sensor
OR
Black
Blue
Ground
Occupancy
sensor switch
Green
Ground
120 V~
50 / 60 Hz
Hot / Live
Neutral
Load
Standard
mechanical switch
Black
Jumper wire
Bare
Different color screw
(Common)
Green
screw
Black
Blue
Green
Ground
Occupancy
sensor switch
Ground
120 V~
50 / 60 Hz
Hot / Live
Neutral
Load
Standard
mechanical switch
Black
Jumper wire
Bare
Different color screw
(Common)
Green
screw
3-way Installation with Standard Mechanical Switch (120 V~)
3, 4
-OPS6M2U-DV, -VPS6M2U-DV
Wiring Diagram 8 - without Neutral
Wiring Diagrams (continued)
1
When using controls in single location installations, tighten the blue terminal or cap blue wire. Do NOT connect the blue terminal / wire to any other
wire or to ground.
2
Fan load applies to 120 V~ only (not for 277 V~).
3
Only one occupancy sensor switch can be used per multi-location circuit.
4
A single standard mechanical 3-way switch or up to 9 companion switches may be connected to most occupancy sensor switches.
Standard mechanical 3-way switch cannot be combined with companion switch. Total blue terminal wire length may be up to 150ft (46m).
Continued on next page...
Note: Remove white sleeve and connect green wire to ground only in retrofit and replacement applications.
18
Maestro Sensor
369666f 19 09.05.19
®
SPECIFICATION SUBMITTAL Page
Job Name:
Job Number:
Model Numbers:
Switch with Occupancy / Vacancy Sensor
1
Only one occupancy sensor switch can be used per multi-location circuit.
2
A single standard mechanical 3-way switch or up to 9 companion switches may be connected to most occupancy sensor switches.
Standard mechanical 3-way switch cannot be combined with companion switch. Total blue terminal wire length may be up to 150ft (46m).
3
Fan load applies to 120 V~ only (not for 277 V~).
Wiring Diagrams (continued)
Continued on next page...
3-way Installation with Standard Mechanical Switch (277 V~)
1, 2, 3
-OPS6M2U-DV, -VPS6M2U-DV
Wiring Diagram 9 - with Neutral
OR
Black
Blue
White-sleeved wire
Ground
Occupancy
sensor switch
Ground
277 V~
50 / 60 Hz
Hot / Live
Neutral
Load
Standard
mechanical switch
Black
Jumper wire
Bare
Different color screw
(Common)
Green
screw
Black
Blue
Ground
Occupancy
sensor switch
White-sleeved
wire
Ground
277 V~
50 / 60 Hz
Hot / Live
Neutral
Load
Standard
mechanical switch
Black
Jumper wire
Bare
Different color screw
(Common)
Green
screw
Note: When a neutral connection is available, connect the white-sleeved wire to neutral.
19
Maestro Sensor
369666f 20 09.05.19
®
SPECIFICATION SUBMITTAL Page
Job Name:
Job Number:
Model Numbers:
Switch with Occupancy / Vacancy Sensor
1
Only one occupancy sensor switch can be used per multi-location circuit.
2
A single standard mechanical 3-way switch or up to 9 companion switches may be connected to most occupancy sensor switches.
Standard mechanical 3-way switch cannot be combined with companion switch. Total blue terminal wire length may be up to 150ft (46m).
3
Fan load applies to 120 V~ only (not for 277 V~).
Continued on next page...
Wiring Diagrams (continued)
OR
Black
Blue
Green
Ground
Occupancy
sensor switch
Ground
277 V~
50 / 60 Hz
Hot / Live
Neutral
Load
Standard
mechanical switch
Black
Jumper wire
Bare
Different color
screw (Common)
Green
screw
Black
Blue
Ground
Occupancy
sensor switch
Green
Ground
277 V~
50 / 60 Hz
Hot / Live
Neutral
Load
Standard
mechanical switch
Black
Jumper wire
Bare
Different color
screw (Common)
Green
screw
3-way Installation with Standard Mechanical Switch (277 V~)
1, 2, 3
-OPS6M2U-DV, -VPS6M2U-DV
Wiring Diagram 9 - without Neutral
Note: Remove white sleeve and connect green wire to ground only in retrofit and replacement applications.
20
Maestro Sensor
369666f 21 09.05.19
®
SPECIFICATION SUBMITTAL Page
Job Name:
Job Number:
Model Numbers:
Switch with Occupancy / Vacancy Sensor
Wiring Diagrams (continued)
1
A single standard mechanical 3-way switch or up to 9 companion switches may be connected to most occupancy sensor switches.
Standard mechanical 3-way switch cannot be combined with companion switch. Total blue terminal wire length may be up to 150ft (46m).
2
Only one occupancy sensor switch can be used per multi-location circuit.
3
Occupancy sensor switch can be installed in any location.
4
Fan load applies to 120 V~ only (not for 277 V~).
Wiring Diagram 10 - without Neutral
Multi-Location Installation (120 V~)
1, 2, 3
-OPS6M2U-DV, -VPS6M2U-DV with MA-AS or MSC-AS
MA-AS or
MSC-AS
MA-AS or
MSC-AS
Blue
Green
Ground
Occupancy
sensor switch
3
Black
Ground
120 V~
50 / 60 Hz
Brass Brass
Black
Blue
Blue
Green
Green
Ground
Hot /
Live
Neutral
Load
Bare
Black Black
Continued on next page...
Wiring Diagram 10 - with Neutral
Multi-Location Installation (120 V~)
1, 2, 3
-OPS6M2U-DV, -VPS6M2U-DV with MA-AS or MSC-AS
MA-AS or
MSC-AS
MA-AS or
MSC-AS
Blue
White-sleeved wire
Ground
Occupancy
sensor switch
3
Black
Ground
120 V~
50 / 60 Hz
Brass Brass
Black
Blue
Blue
Green
Green
Ground
Hot / Live
Neutral
Load
Bare
Black Black
Note: Remove white sleeve and connect green wire to ground only in retrofit and replacement applications.
Note: When a neutral connection is available, connect the white-sleeved wire to neutral.
21
Maestro Sensor
369666f 22 09.05.19
®
SPECIFICATION SUBMITTAL Page
Job Name:
Job Number:
Model Numbers:
Switch with Occupancy / Vacancy Sensor
Wiring Diagrams (continued)
Continued on next page...
1
A single standard mechanical 3-way switch or up to 9 companion switches may be connected to most occupancy sensor switches.
Standard mechanical 3-way switch cannot be combined with companion switch. Total blue terminal wire length may be up to 150ft (46m).
2
Only one occupancy sensor switch can be used per multi-location circuit.
3
Occupancy sensor switch can be installed in any location.
4
Fan load applies to 120 V~ only (not for 277 V~).
Wiring Diagram 11 - without Neutral
Multi-Location Installation (277 V~)
1, 2, 3, 4
-OPS6M2U-DV, -VPS6M2U-DV with MA-AS-277 or MSC-AS-277
Occupancy
sensor switch
3
Black
Blue
Green
Ground
Black
Blue
Green
Ground
277 V~
50 / 60 Hz
Black
Blue
Green
Ground
Hot/Live
Neutral
Load
Red
Red
Bare
Black
MA-AS-277 or
MSC-AS-277
MA-AS-277 or
MSC-AS-277
Wiring Diagram 11 - with Neutral
Multi-Location Installation (277 V~)
1, 2, 3, 4
-OPS6M2U-DV, -VPS6M2U-DV with MA-AS-277 or MSC-AS-277
Occupancy
sensor switch
3
Black
Blue
White-
sleeved
wire
Ground
Black
Blue
Green
Ground
277 V~
50 / 60 Hz
Black
Blue
Green
Ground
Hot / Live
Neutral
Load
Red
Red
Bare
Black
MA-AS-277 or
MSC-AS-277
MA-AS-277 or
MSC-AS-277
Note: When a neutral connection is available, connect the white-sleeved wire to neutral.
Note: Remove white sleeve and connect green wire to ground only in retrofit and replacement applications.
22
Maestro Sensor
369666f 23 09.05.19
®
SPECIFICATION SUBMITTAL Page
Job Name:
Job Number:
Model Numbers:
Switch with Occupancy / Vacancy Sensor
Colors and Finishes
Due to printing limitations, colors and finishes shown cannot be guaranteed to match actual product colors perfectly.
• Color chip keychains are available for more precise color matching:
Gloss Finishes: DG-CK-1
Satin Finishes: SC-CK-1
Satin Finishes
Taupe
TP
Plum
PL
Merlot
MR
Terracotta
TC
Sienna
SI
Midnight
MN
Hot
HT
Desert Stone
DS
Eggshell
ES
Biscuit
BI
Snow
SW
Palladium
PD
Greenbriar
GB
Bluestone
BG
Mocha Stone
MS
Goldstone
GS
Stone
ST
Limestone
LS
Gloss Finishes
White
WH
Ivory
IV
Almond
AL
Light Almond
LA
Gray
GR
Brown
BR
Black
BL
)Lutron, Lutron, Maestro, FASS, XCT, and Softswitch are trademarks or registered trademarks of Lutron Electronics Co., Inc. in the US and/or other countries.
UL is a trademark of UL LLC.
For the latest color offerings
please see our website:
http://www.lutron.com/satincolors
23