The sidewalls drop, and tops of temporary membrane structures, tents and canopies shall be composed of flame-
resistant material or shall be treated with a flame retardant in an approved manner.
Floor coverings, bunting, combustible decorative materials, and effects, including sawdust used on floors or
passageways, shall be composed of flame-resistant material or shall be treated with a flame retardant in an
approved manner.
Applicant’s initials: __________
Temporary membrane structures, tents or canopies shall have a permanently affixed label bearing the following
information:
1. Identification of temporary membrane structure, tent or canopy, size, and fabric or material type.
2. For flame-resistant materials, the necessary information to determine compliance with the National Fire
Protection Association (N.F.P.A) Standard 701.
3. For flame-retardant-treated materials, the date that the temporary membrane structure, tent or canopy,
and other combustible materials were last treated with an approved flame retardant.
4. The trade name and type of flame retardant utilized in flame-retardant treatment.
5. The name of the person and firm that applied the flame retardant.
A minimum of one portable fire extinguishers shall be provided and one additional fire extinguishers for every
3000 square feet.
Occupant load requirements shall be per the Prosper Building official.
Seating in temporary membrane structures, tents, or canopies shall be per the area of assembly requirements.
Exits shall be spaced at approximately equal intervals around the perimeter of the temporary membrane structure,
tent or canopy and shall be located such that all points are 100 feet or less from an exit. Every tent and temporary
membrane structure or usable portion thereof shall have at least one exit and not less than the number of exits
required.
Exit openings from tents shall remain open unless covered by a flame-resistant curtain, provided:
1. Curtains shall be free sliding on a metal support. The support shall be a minimum of 8 feet above the
floor level at the exit. The curtains shall be so arranged that, when open, no part of the curtains obstructs
the exit.
2. Curtains shall be of a color, or colors, which contrasts with the color of the tent.
Smoking shall not be permitted in temporary membrane structures, tents, and canopies or in adjacent areas where
hay, straw, sawdust or other combustible materials are stored or used. NO SMOKING signs shall be
conspicuously posted.
Applicant’s initials: _________
Fireworks, open flames, and devices capable of igniting combustible materials shall not be used in or adjacent to a
temporary membrane structure, tent or canopy unless otherwise approved.
Cooking and heating equipment, tanks, piping, hoses, fittings, valves, tubing, and other related components shall
be approved or per the Mechanical Code.
Exception: Operations such as warming of foods, cooking demonstrations, and similar operations, which
do not present an ignition hazard.
Cooking and heating equipment shall be vented to the outside air by approved means. Where vents or flues are
used, all portions of the temporary membrane structure, tent, or canopy shall be no less than 12 inches (305 mm)
from the flue or vent. Solid-fuel-burning equipment shall be equipped with spark arrestors having openings not
exceeding 1/4-inch