SPECIFICATION SUBMITTAL
Job Name:
Job Number:
Standards
• UL listed.
• CSA.
• CEC listed (Title 24).
Scene and Shade Buttons
• Large, rounded buttons are easy to use.
• Backlit buttons with optional engraving make it easy to
find and to operate the control unit in low light
conditions (backlight can be disabled).
• Optional button engraving is angled up to the eye for
easy reading.
• Predefined label stickers are included for field labeling.
Preset Light and Shade Control
• 4 preset lighting scenes, plus Off, are accessible from
the front of the control unit.
• 12 additional scenes are stored in the control unit and
are accessible from SeeTouch
® QS wallstations and
QS integration.
• Light levels fade smoothly between scenes. Fade time
can be set differently for each scene: 0 to 59 seconds,
or 1 to 60 minutes. Maximum fade time from Off is
3 seconds.
• Up to 3 columns of shade control.
• Open, preset, close, and raise/lower shade buttons.
Each shade column can be programmed to operate
one shade or a group of shades.
Zone Control
• Each zone has a dedicated raise and lower button to
adjust the zone.
• Each zone has a dedicated 7 LED bar graph for level
status. Percentage of light level and energy saved is
displayed on the info screen.
• All zone information has blue backlit LEDs. Backlight
turns off when idle for 30 seconds.
Info Screen
• OLED (organic LED) screen is viewable from all angles.
• Screen turns off when idle for 30 seconds.
• Programmable zone labels.
• Programmable scene labels.
• Status of real-time zone percentage and energy
savings.
• Programmable timeclock schedules.
• Programmable shade labels.
Input Power
• 120 V 50/60 Hz
• Lightning strike protection meets ANSI/IEEE standard
62.41-1980. Can withstand voltage surges of up to
6000 V and current surges of up to 3000 A.
Lighting Sources/Load Types
• EcoSystem, Hi-lume
® 3D, and Hi-lume® LED ballasts
(available on all zones).
Zones 1, 2, and 3 control the following lighting sources
with a smooth, continuous square law dimming curve or
on a full conduction non-dim basis:
• Incandescent.
• Halogen.
• Magnetic low-voltage transformer.
• Lutron Tu-Wire
® electronic fluorescent dimming ballast.
• Neon and cold cathode.
• Non-dim (incandescent, magnetic low-voltage, Tu-Wire,
or neon/cold cathode).
Zones 1, 2, and 3 control the following lighting sources
with a smooth, continuous square law dimming curve
through separate Lutron PHPM series power modules:
• Electronic low-voltage transformer.
• Lutron Hi-Lume
®, Eco-10
TM, and Compact SE electronic
fluorescent dimming ballast.
Key Design Features
• Tested to withstand 16 kV electrostatic discharge without
damage or memory loss.
• RTISS
TM
-equipped: Compensates in real time for
incoming line voltage variations (no visible flicker with +/-
2% change in RMS voltage per cycle, and +/-2% Hz
change in frequency per second).
• Power failure memory automatically restores
lighting to the scene selected prior to power
interruption, and stores timeclock and scene
programming.
• Faceplate is hinged top and bottom and stays open at
180° for ease of access.
• Direct control of 120 V and 277 V EcoSystem,
Hi-lume
® 3D, and Hi-lume® LED ballasts (no interface
required).
Environment
• 32-104 °F (0-40 °C).
• Relative humidity less than 90% non-condensing.
Specifications