Preset Dimming Controls
OMX-4600
4600-1 01.05.06
R
Job Name:
Job Number:
Model Numbers:
Page
SPECIFICATION SUBMITTAL
GRAFIK Systems
OMX-4600 Control Unit
Cover (shown open)
Infrared Receiver
Scene Selection
Buttons
ZoneBase
Description
• Used with GRAFIK 5000/6000/7000
Centralized Lighting Control Systems.
• Supplies dimming for up to 24 zones of
lighting
1
.
• Provides pushbutton recall of four preset
lighting scenes, plus Off.
• Controls virtually any light source via dimming
and switching panels.
• Provides lockout options to prevent
accidental changes.
• Includes built-in infrared receiver for
operation with an optional remote control.
Models available to:
• Control two to 24 zones of lighting
1
.
1
OMX-4600 Control Unit zones count towards the maximum number of zones allowed in
GRAFIK 5000/6000/7000 Systems.
1
Preset Dimming Controls
OMX-4600
4600-2 01.05.06
R
Model Numbers:
Page
SPECIFICATION SUBMITTAL
GRAFIK Systems
Job Name:
Job Number:
Key Design Features
• Meets IEC 801-2. Tested to withstand 15kV
electrostatic discharge without damage or
memory loss.
• Power failure memory automatically restores
lighting to the scene selected prior to power
interruption.
• Faceplate snaps on with no visible means of
attachment.
System Communications and Capacities
• Low-voltage type Class 2 (PELV) wiring connects
Control Units to other system components.
• The OMX-4600 Control Unit counts as one of 32
maximum Wallstations and/or Control Interfaces
allowed on a Class 2 (PELV) Control Station
Device Link.
Environment
• 32-104°F (0-40°C). Relative humidity less than
90% non-condensing.
Power
• Low-voltage type Class 2 (PELV)
Operating voltage: 32 V Direct Current.
Lighting Sources/Load Types
Controls lighting sources with a smooth, continuous
Square Law dimming curve or on a full conduction
non-dim basis via GP and LP Dimming Panels and
XP Softswitch
TM Panels.
Preset Control
• 4 preset lighting scenes and off are accessible from
the Control Unit front panel.
• Additional scenes are stored in Processor Panel.
These scenes are accessible via Wallstations,
Control Interfaces, and/or PC.
• Light levels fade smoothly between scenes. Fade
time can be set differently for each scene, between
0-59 sec. or 1-60 min. Fade time from Off is
capped at 5 sec. Fade time can be set differently
for each zone through the Processor.
Specifications
2
Preset Dimming Controls
OMX-4600
4600-3 01.05.06
R
Job Name:
Job Number:
Model Numbers:
Page
SPECIFICATION SUBMITTAL
GRAFIK Systems
Cover Options
Opaque A
Cover and Base will match.
Translucent Black T
Black Cover and choice of
Base color.
How to Build a Model Number
O M X - 4 6 0 6 - T - W H
Prefix
Number
of Zones
Cover
Option
Color
Option
Color Options
Architectural Matte Finishes
Standard – Ship in 48 hours
Cover Option: A or T
White WH
Ivory IV
Beige BE
Gray GR
Brown BR
Black BL
Designer Gloss Finishes
Ship in 4 to 6 weeks
Cover Option: A only
White GWH
Ivory GIV
Light Almond GLA
Almond GAL
Satin Color Matte Finishes
Cover Option: A or T
Hot HT
Ochre OC
Terracotta TC
Desert Stone DS
Stone ST
Limestone LS
Blue Mist BT
Midnight MN
Taupe TP
Biscuit BI
Eggshell ES
Snow SW
Architectural Metal Finishes
Cover Option: T only
Bright Brass BB
Bright Chrome BC
Bright Nickel BN
Satin Brass SB
Satin Chrome SC
Satin Nickel
SN
Antique Brass QB
Antique Bronze QZ
Anodized Aluminum Finishes
Cover Option: T only
Clear CLA
Black
BLA
Brass BRA
Bronze BZA
Prefix:
OMX
for Control Units used with
GRAFIK 5000/6000/7000 systems.
Number of Zones:
2, 3, 4, 6, 8, 16, or 24
Cover Option:
A
for Opaque
T for Translucent Black
Color Option:
See Color Options list
Also available:
- Custom controls
- Color matching
- Engraving
These options ship in 4 to
6 weeks.
Number
of Zones
2
3
4
6
8
16
24
Standard Setup
OMX-4602-_-__
OMX-4603-_-__
OMX-4604-_-__
OMX-4606-_-__
OMX-4608-_-__
OMX-4616-_-__
OMX-4624-_-__
Model Numbers
3
Preset Dimming Controls
OMX-4600
4600-4 01.05.06
R
Job Name:
Job Number:
Model Numbers:
Page
SPECIFICATION SUBMITTAL
GRAFIK Systems
Dimensions and Mounting
W
allbox
1
M
odel Side View
ABCU.S.
Size Depth
2-Zone: 4 5/16" 1 13/16" 5.56" 2 Gang 3.5"
OMX-4602 (123mm) (46mm) (141mm) (89mm)
3-Zone: 6 11/16" 3 5/8” 7.25” 3 Gang 3.5"
OMX-4603 (168mm) (92mm) (184mm) (89mm)
4-Zone: 8 5/16” 5 7/16” 8.94” 4 Gang 3.5"
OMX-4604 (208mm) (138mm) (227mm) (89mm)
6-Zone: 8 5/16” 5 7/16” 8.94” 4 Gang 3.5"
OMX-4606 (208mm) (138mm) (227mm) (89mm)
8-Zone: 8 5/16” 5 7/16” 8.94” 4 Gang 3.5"
OMX-4608 (208mm) (138mm) (227mm) (89mm)
16-Zone: 8 5/16” 5 7/16” 8.94” 4 Gang 3.5"
OMX-4616 (208mm) (138mm) (227mm) (89mm)
24-Zone: 8 5/16” 5 7/16” 8.94” 4 Gang 3.5"
OMX-4624 (208mm) (138mm) (227mm) (89mm)
B
3 5/16"
(85mm)
3 1/2" (89mm) wallbox depth recommended
C
A
5/16"
(8 mm)
1 15/16"
(49 mm)
4 9/16"
(116 mm)
1
Can be ordered from Lutron.
4
SSA
SSA RTN
DO NOT USE
2 IN, OUT
1 IN, OUT
DO NOT USE
MUX (4) IN
MUX (3) IN
MUX (4) OUT
MUX (3) OUT
USA: CLASS 2
IEC: PELV
CU WIRE ONLY
1 2 3 4 5
34
34
Preset Dimming Controls
OMX-4600
4600-5 01.05.06
R
Job Name:
Job Number:
Model Numbers:
Page
SPECIFICATION SUBMITTAL
GRAFIK Systems
Low-Voltage Class 2 (PELV) Wiring
• All wiring must be daisy-chained.
• Make connections in the Control Unit’s wallbox or in a
switch/junction box with a maximum wire length of 8 feet
(2.5m) from the link to the Control Unit.
• Keep Shield/Drain continuous but do not ground. Connect
the bare drain wires and cut off the outside shield. Do not
connect to Ground (Earth) or Wallstations/Control
Interfaces.
• Begin and end the wiring link with Link Terminators.
OMX-4603 Control Unit
Link
T
erminator
Link
T
erminator
Last Wallstation/Control Interface
Ceiling Receiver
Processor
Panel
Data Link
(1) Shielded, twisted
pair #18 AWG (1.0mm
2
)
3: MUX
4: MUX
Contr
ol W
iring
(2) #12 AWG (2.5mm
2
)
1: Common
2: 32VDC
5