SPECIFICATION SUBMITTAL Page
Job Name:
Job Number:
Model Numbers:
GRAFIK Systems OMX-CCO-8 Control Interfaces
OMX-CCO-8 1 09.03.08
OMX-CCO-8
Description
Integrates control of third party motorized
window treatments or A / V equipment with
GRAFIK 5000/6000/7000
TM, LCP128TM and
Softswitch128
® Systems.
The OMX-CCO-8 provides eight dry contact
closure outputs.
Features
The OMX-CCO-8 provides both normally open
(NO) and normally closed (NC) contacts.
The OMX-CCO-8 may be set to momentary or
maintained outputs.
The outputs may be set as individual outputs or
motorized window treatment channels.
Motorized window treatment channels may be
set to have OPEN and CLOSE outputs or OPEN,
STOP, and CLOSE outputs.
Manual override buttons allow the testing of the
system.
Coopersburg, PA USA
www.lutron.com
OMX-CCO-8
PELV (Class 2 USA)
US/Canada: 1-800-523-9466
Great Britain: +44-207-702-0657
Deutschland: +49-30-9710-4590
Espana: +34-91-567-8479
France: +33-1–4470-7200
OMX-CC0-8
1
2
3
4
5
6
7
8
Singapore: +65-6220-4666
Japan: +81-3-5575-8411
Hong Kong: +852-2104-7733
Vdc
V~
R L
0 - 30 1.0 A
30 - 42 0.5 A
V
R
NC
NO
C
OMX-CCO v1.1 144-759 BR2 L20
IEC/EN 60669-2-1
IP20
m
CNONC
Output 1
CNONC
Output 2
CNONC
Output 3
CNONC
Output 4
CNONC
Output 5
CNONC
Output 6
CNONC
Output 7
CNONC
Output 8
COM +V MUX MUX
OPTIONS ADDRESS
1 2 3 4 51 2 3 4 5
Output
Status LED
(typical of 8)
Manual
Override
Buttons
(typical of 8)
Control Link
Options
Switches
Mounting Hole
(typical of 2)
Address
Switches
Status LED
Contact
Closure
Outputs
(typical of 8)
1
®
SPECIFICATION SUBMITTAL Page
Job Name:
Job Number:
Model Numbers:
GRAFIK Systems OMX-CCO-8 Control Interfaces
OMX-CCO-8 2 09.03.08
Specifi cations
Power
Class 2 (PELV)
Operating voltage: 32 VDC
System Communications
Class 2 (PELV) wiring connects OMX-CCO-8
to Central Processor and other components.
OMX-CCO-8 occupies one of 32 Wallstation
addresses on the GRAFIK Systems Control Link.
Environment
32 °F (0 °C) to 104 °F (40 °C)
Relative humidity less than 90%, non-condensing.
Output Ratings
Note: The OMX-CCO-8 is not rated to control
unclamped, inductive loads. Inductive loads include,
but are not limited to, relays, solenoids, and motors.
To control these types of equipment, a fl yback diode
must be used (DC voltages only). See diagram.
Supply Voltage Resistive Load
R
0-30 V 1.0 A
30-42 V 0.5 A
+
-
Flyback
Diode
GRX-CCO-8
Output
Inductive
Load
DC
2
®
SPECIFICATION SUBMITTAL Page
Job Name:
Job Number:
Model Numbers:
GRAFIK Systems OMX-CCO-8 Control Interfaces
OMX-CCO-8 3 09.03.08
Dimensions and Mounting
Mount the OMX-CCO-8 on a clean, dry surface.
Allow 4.5" (114 mm) between the OMX-CCO-8 and
other equipment/walls.
Internal relays will click while in operation. Mount
where this is acceptable.
Mount in a location that is accessible for system
programming and setup.
Coopersburg, PA USA
www.lutron.com
OMX-CCO-8
PELV (Class 2 USA)
US/Canada: 1-800-523-9466
Great Britain: +44-207-702-0657
Deutschland: +49-30-9710-4590
Espana: +34-91-567-8479
France: +33-1–4470-7200
OMX-CC0-8
1
2
3
4
5
6
7
8
Singapore: +65-6220-4666
Japan: +81-3-5575-8411
Hong Kong: +852-2104-7733
Vdc
V~
R L
0 - 30 1.0 A
30 - 42 0.5 A
V
R
NC
NO
C
OMX-CCO v1.1 144-759 BR2 L20
IEC/EN 60669-2-1
IP20
m
5-3/4"
(146.1 mm)
10-3/4"
(273.1 mm)
2"
(50.29 mm)
3
®
SPECIFICATION SUBMITTAL Page
Job Name:
Job Number:
Model Numbers:
GRAFIK Systems OMX-CCO-8 Control Interfaces
OMX-CCO-8 4 09.03.08
Operating Modes
Motorized Window Treatment Channels
Applications
Integrate the control of motorized window treatments with
GRAFIK Systems in existing applications (retrofi t).
Integrate the control of motorized window treatments with
a GRAFIK Systems when third party motor controllers are
used.
Operation
Two or three outputs are grouped together to form a
Motorized Window Treatment (MWT) channel. These
outputs provide the OPEN, STOP, and CLOSE signals to
control third party motor controllers (see diagram below).
The method in which the OMX-CCO-8 stops motorized
window treatments is selectable to accommodate
different types of motor controllers.
- Pulse the OPEN and CLOSE outputs simultaneously.
- Pulse the most recent output again.
- Pulse a dedicated STOP output (Uses three outputs per
channel. In this confi guration, the OMX-CCO-8 may
have a maximum of 2 MWT channels).
Set the number of MWT channels from 0 to 4 to fi t your
application.
Outputs not used in MWT channels may be used as
individual outputs. Example: If there are two MWT
channels, and there are three outputs per MWT channel,
there will be two outputs left over to be used as individual
outputs.
Outputs may be set as momentary or maintained.
CNONC
Output 1
CNONC
Output 2
CNONC
Output 3
CNONC
Output 4
CNONC
Output 5
CNONC
Output 6
CNONC
Output 7
CNONC
Output 8
COM +V MUX MUX
OPTIONS ADDRESS
1 2 3 4 51 2 3 4 5
2 Outputs per Channel
CNONC
Output 1
CNONC
Output 2
CNONC
Output 3
CNONC
Output 4
CNONC
Output 5
CNONC
Output 6
CNONC
Output 7
CNONC
Output 8
COM +V MUX MUX
OPTIONS ADDRESS
1 2 3 4 51 2 3 4 5
3 Outputs per Channel
Close
Open
Close
Open
Close
Open
Close
Open
Close
Open
Close
Open
Stop Channel 1
Stop Channel 2
2 Individual Outputs
Channel 4
Channel 3
Channel 2
Channel 1
4
®
SPECIFICATION SUBMITTAL Page
Job Name:
Job Number:
Model Numbers:
GRAFIK Systems OMX-CCO-8 Control Interfaces
OMX-CCO-8 5 09.03.08
System Diagram - Motorized Window Treatment Control
Coopersburg, PA USA
www.lutron.com
OMX-CCO-8
PELV (Class 2 USA)
US/Canada: 1-800-523-9466
Great Britain: +44-207-702-0657
Deutschland: +49-30-9710-4590
Espana: +34-91-567-8479
France: +33-1–4470-7200
OMX-CC0-8
1
2
3
4
5
6
7
8
Singapore: +65-6220-4666
Japan: +81-3-5575-8411
Hong Kong: +852-2104-7733
Vdc
V~
RL
0 - 30 1.0 A
30 - 42 0.5 A
V
R
NC
NO
C
OMX-CCO v1.1 144-759 BR2 L20
IEC/EN 60669-2-1
IP20
m
Processor
Panel
GRAFIK Eye
®
Wallstation
GRAFIK Systems
Wallstation Control Link
(32 maximum controls
per link)
OMX-CCO-8 Outputs
Class 2/PELV
MWT
Channels
Third Party Motor
Controller
Individual
Outputs
A/V
Equipment
AC
Motorized
Window
Treatment
Controller
OMX-CCO-8
5
®
SPECIFICATION SUBMITTAL Page
Job Name:
Job Number:
Model Numbers:
GRAFIK Systems OMX-CCO-8 Control Interfaces
OMX-CCO-8 6 09.03.08
Operating Modes
Individual Outputs
Applications
Control A/V or other equipment.
Provide status feedback to third party systems.
Operation
The OMX-CCO-8 output is opened or closed based
on commands from the GRAFIK Systems central
processor.
Coopersburg, PA USA
www.lutron.com
OMX-CCO-8
PELV (Class 2 USA)
US/Canada: 1-800-523-9466
Great Britain: +44-207-702-0657
Deutschland: +49-30-9710-4590
Espana: +34-91-567-8479
France: +33-1–4470-7200
OMX-CC0-8
1
2
3
4
5
6
7
8
Singapore: +65-6220-4666
Japan: +81-3-5575-8411
Hong Kong: +852-2104-7733
Vdc
V~
R L
0 - 30 1.0 A
30 - 42 0.5 A
V
R
NC
NO
C
OMX-CCO v1.1 144-759 BR2 L20
IEC/EN 60669-2-1
IP20
m
System Diagram - Individual Outputs
Processor
Panel
GRAFIK Eye
®
Wallstation
GRAFIK Systems
Wallstation Control Link
(32 maximum controls
per link)
OMX-CCO-8
Outputs Class
2/PELV Wiring
A/V
Equipment
OMX-CCO-8
6