SPECIFICATION SUBMITTAL Page
Job Name:
Job Number:
Model Numbers:
LMR-SALTO-PR Software LicenseLutron
369922c 3 01.08.19
SALTOR Systems Requirements
The Lutron myRoom plus system is compatible with
all wireless SALTO access control systems that
operate using either the SALTOR ProAccess SPACET,
SALTOR HAMST, or SALTOR ProAccessT software via
the SALTOR Event StreamT interface.
SALTOR is responsible for the complete design,
installation, start-up, and maintenance of all system
components necessary for their wireless online
door-lock system to operate. This includes, but is not
limited to, the following:
• Electronicdoorlockswiththerequiredonline
hardware installed.
• Wirelessgatewaysthatallowthedoorlocksto
communicate over the hotel network.
• CoordinatingtherequiredwiringforallSALTOR
equipment.
• SALTOR ProAccess SPACET version 1 or above,
SALTOR HAMST version 11 or above, or SALTOR
ProAccessT version 12 or above.
• Serverhardwareorenvironmentforhostingthe
SALTOR software.
• SALTOR Event StreamT interface version 1.3 or above
on the SALTOR server to allow communication to the
Lutron myRoom server.
Lutron System Requirements
Only the Lutron myRoom plus system is compatible
with the SALTOR door lock system.
The Lutron myRoom plus system BOM must include
the following:
• LMR-VSBO:myRoomserverbyothersor
LMR-CMP-R: myRoom plus server by Lutron.
• LMR-SALTO-PR:myRoomplus-SALTOR interface
software licenses; one license required per
guestroom.
• LMR-EO:myRoomplusnetworkingrequirements.
Network Requirements
To ensure acceptable end-to-end system response
time and a positive guest experience, the hotel
network must meet the following requirements:
• TheLutronserverandallGCU-HOSPunitsmust
sharethesamesubnetonadedicatedVLAN.
• TheSALTOR server and all SALTOR wireless gateways
mustsharethesamesubnetonadedicatedVLAN.
• TCPcommunicationmustbeallowedonthe
corresponding, configured port from the Lutron
myRoom plus server to the SALTOR server.
Commissioning Requirements
• LutronshallbeprovidedwiththeIPandportfrom
which the SALTOR server will be communicating.
• Lutronshallbeprovidedwiththeexact,
commissioned names for all SALTOR system door
locks.
• Roomautomationusingdoorlocksystem
integration requires a fully commissioned door lock
system, servers (Lutron and SALTOR), and network
infrastructure.
Mock-Up Demonstration Requirements
If integration with the SALTOR door locking system
must be demonstrated for a hotel mock-up room
review, it will require close coordination between the
local Lutron and SALTOR sales, project management,
and start-up teams. The SALTOR wireless gateway,
the SALTOR server, and the Lutron myRoom plus
server all need to be included in the mock-up.
)Lutron and Lutron are trademarks of Lutron Electronics Co., Inc., registered in the U.S. and other countries.
myRoom is a trademark of Lutron Electronics Co., Inc.
SALTO, ProAccess, ProAcess SPACE, Event Stream, and HAMS are trademarks of Salto Systems, S.L.
Opera is a trademark of MICROS Systems, Inc.