SPECIFICATION SUBMITTAL Page
Job Name:
Job Number:
Model Numbers:
Switching/0-10 V Power Module LQSE-4 Switching / 0-10 V Fixture Controller
369610a 1 07.18.12
Power Module
The Power Module family is a group of modular products
for the control of lighting loads. This document describes
the following products:
•Model Number: LQSE-4S10-D - Power Module unit for
Switching only
•Model Number: LQSE-4T10-D - Power Module unit for
0-10 V/Switching
Features
•IncludesQSlinkforseamlessconnectiontoa
HomeWorksR QS system.
•PowerModuleunitscanbeusedinaHomeWorksR QS
system to control and manage light in an entire home or
building.
MUX
COM
MUX
QS
Def
Opt1
Opt2
0-10 V Power Module
LQSE-4T10-D
230 V~ 50/60 Hz 50 mA
www.lutron.com +44.(0)20.7680.4481
1 2
3
4
Outputs 230 V~ 10 AX each
Zone 1Zone 2Zone 3Zone 4
Option
L
N
µ
Z096
Opt3
CCI
CCI
COM
0,5 N•m
All Others
8 mm
1,2 N•m
Mains Only
Input
Hi Temp
Program
Power
H
M
L
Zones
0-10 V-
50 mA
Up
MUX
COM
MUX
QS
Def
Opt1
Opt2
Switching Power Module
LQSE-4S10-D
230 V~ 50/60 Hz 50 mA
www.lutron.com +44.(0)20.7680.4481
1 2
3
4
Outputs 230 V~ 10 AX each
Zone 1Zone 2Zone 3Zone 4
Option
L
N
µ
Z096
Opt3
CCI
CCI
COM
0,5 N•m
All Others
8 mm
1,2 N•m
Mains Only
Input
Hi Temp
Program
Power
H
M
L
Up
LQSE-4T10-D
LQSE-4S10-D
System Example
QSLink
Power
Module
Switching/0-10 V
Power Module
GRAFIK
EyeR QS
QS
Contact
Closure
Interface
HomeWorksR
QS
Processor
HomeWorksR QS
Wallstation
SivoiaR QS
Shades/Draperies
ContactClosureInput
Up to
100
total QS
devices
230 V
Control Power
QS Power
Supply
(4) switched outputs, 10 AX each (zones 1-4)
(4) 0-10 V outputs (zones 1-4)
(model LQSE-4T10-D only)
1
®
SPECIFICATION SUBMITTAL Page
Job Name:
Job Number:
Model Numbers:
Switching/0-10 V Power Module LQSE-4 Switching / 0-10 V Fixture Controller
369610a 2 07.18.12
Specifications
Power
•230V
50/60 Hz
•LightningstrikeprotectionmeetsANSI/IEEEstandard
62.31-1980. Can withstand voltage surges of up to
6 000 V
and current surges of up to 3 000 A.
•Currentdraw:50mAmax
•Standbypower:1W
•BTUs/hourwhenfullyloaded:4
Output Zone Ratings
•Eachzoneisratedat10AXforswitching.Ratedforre-
sistive, capacitive, or inductive lighting loads as defined
byIEC/EN60669-2-1.
Switched outputs utilize latching relays to maintain
relay state if control power is lost.
0-10Vratedfor50mAmaximumoutput,sourceor
sinkperzone.
Standards
•IEC/EN60669-2-1,EN50428
•LutronQualitySystemsregisteredtoISO9001:2008
•CE
•C-TickS
Environment
•AmbientTemperatureOperatingRange(inside
mounting panel): 0 ºC to 40 ºC
•Calibrationpointmaximum:65ºC
•Relativehumidity:lessthan90%non-condensing
•Forindooruseonly
Terminals
•Mainswiring:0,5mm
2
to 6,0 mm
2
•0-10VWiring:0,5mm
2
to 2,5 mm
2
•CCIWiring:0,5mm
2
to 6,0 mm
2
•Zonewiring:0,5mm
2
to 6,0 mm
2
Mounting
•UseanIP20(minimum)ratedconsumerpanelor
breakerpanelwithintegratedDINrail
•Width=9modules(161,7mm)
Programming and Compatibility Requirements
•LQSE-4T10-DandLQSE-4S10-Dcanonlybeused
withtheHomeWorksRQS system.
•SetupandprogrammingoftheDALIR Power Module
isdonethroughtheHomeWorksRQS programming
software.
•HomeWorks
®QS software version 3,0 or higher
required.
HomeWorksR QS Wallstations
•HomeWorksR QS wallstations can be configured to
control Power Modules withtheHomeWorksR QS
programming utility.
•LEDindicatordisplaysthestatusofprogrammedlights.
QS Link Limits
•AQSlinkinaHomeWorksR QS system can have up to
512 zones (outputs) and 100devices.
•EachPowerModulecountsasonedevicetowardthe
100 device limit.
Manual Mode Operation
•Zonebuttons:
selects zone to control
•Raise/Lowerbuttons:
turns loads on and off
dim loads up and down (LQSE-4T10-D only)
NOTE:Program,Input,andOptionbuttonsarenot
used in LQSE models.
Contact Closure Input (CCI)
•TheCCIbehavesasaManualOverrideClosureInput.
•IftheCCIisopen,thePowerModuleunitwillenter
ManualOverrideMode,whichwillturnonallloads
and disable control from other devices.
•WhentheCCIisclosedorjumpered(factorydefault),
Power Module unit zones will return to the settings or
levelstheywereatpriortoenteringManualOverride
Mode.
2
®
SPECIFICATION SUBMITTAL Page
Job Name:
Job Number:
Model Numbers:
Switching/0-10 V Power Module LQSE-4 Switching / 0-10 V Fixture Controller
369610a 3 07.18.12
Overview of Wiring Terminals
MUX
COM
MUX
QS
Def
Opt1
Opt2
0-10 V Power Module
LQSE-4T10-D
230 V~ 50/60 Hz 50 mA
www.lutron.com +44.(0)20.7680.4481
1 2
3
4
Outputs 230 V~ 10 AX each
Zone 1Zone 2Zone 3Zone 4
Option
L
N
µ
Z096
Opt3
CCI
CCI
COM
0,5 N•m
All Others
8 mm
1,2 N•m
Mains Only
Input
Hi Temp
Program
Power
H
M
L
Zones
0-10 V-
50 mA
Up
MUX
COM
MUX
QS
Def
Opt1
Opt2
Switching Power Module
LQSE-4S10-D
230 V~ 50/60 Hz 50 mA
www.lutron.com +44.(0)20.7680.4481
1 2
3
4
Outputs 230 V~ 10 AX each
Zone 1Zone 2Zone 3Zone 4
Option
L
N
µ
Z096
Opt3
CCI
CCI
COM
0,5 N•m
All Others
8 mm
1,2 N•m
Mains Only
Input
Hi Temp
Program
Power
H
M
L
Up
Mains
Wiring
Mains
Wiring
QS
Link
QS
Link
Contact
Closure
Input
Contact
Closure
Input
Zone
1
Zone
1
Zone
1
Zone
2
Zone
2
Zone
2
Zone
3
Zone
3
Zone
3
Zone
4
Zone
4
Zone
4
0-10 V Channels
LQSE-4T10-D
LQSE-4S10-D
Load power and switched outputs
Load power and switched outputs
IEC PELV
IEC PELV
3
®
SPECIFICATION SUBMITTAL Page
Job Name:
Job Number:
Model Numbers:
Switching/0-10 V Power Module LQSE-4 Switching / 0-10 V Fixture Controller
369610a 4 07.18.12
Mechanical Dimensions
MUX
COM
MUX
QS
Def
Opt1
Opt2
0-10 V Power Module
LQSE-4T10-D
230 V~ 50/60 Hz 50 mA
www.lutron.com +44.(0)20.7680.4481
1 2
3
4
Outputs 230 V~ 10 AX each
Zone 1Zone 2Zone 3Zone 4
Option
L
N
µ
Z096
Opt3
CCI
CCI
COM
0,5 N•m
All Others
8 mm
1,2 N•m
Mains Only
Input
Hi Temp
Program
Power
H
M
L
Zones
0-10 V-
50 mA
Up
MUX
COM
MUX
QS
Def
Opt1
Opt2
Switching Power Module
LQSE-4S10-D
230 V~ 50/60 Hz 50 mA
www.lutron.com +44.(0)20.7680.4481
1 2
3
4
Outputs 230 V~ 10 AX each
Zone 1Zone 2Zone 3Zone 4
Option
L
N
µ
Z096
Opt3
CCI
CCI
COM
0,5 N•m
All Others
8 mm
1,2 N•m
Mains Only
Input
Hi Temp
Program
Power
H
M
L
Up
LQSE-4T10-D
LQSE-4S10-D
161,7
mm
60,6 mm
89,7mm
89,7mm
500-13431 Rev. B
N1771
Z096
4
®
SPECIFICATION SUBMITTAL Page
Job Name:
Job Number:
Model Numbers:
Switching/0-10 V Power Module LQSE-4 Switching / 0-10 V Fixture Controller
369610a 5 07.18.12
Mains Voltage Wiring
Wiring from Distribution to Power Module unit
•Turnoffallcircuitbreakersorisolatorsfeedingthe
Power Module unit at distribution panel.
•Runlive,neutral,andearth(
) wires from a
230 V
50/60 Hz feed to the Power Module unit.
Mains Wiring and IEC PELV Separation
•Followappropriatelocalandnationalcodestoavoid
violating required separation guidelines.
Behavior During Power Failure
•Relaysdonotchangestatewhenpowerislosttothe
L/N/
terminals. Follow local and national codes for
emergency lighting requirements.
MUX
COM
MUX
QS
Def
Opt1
Opt2
0-10 V Power Module
LQSE-4T10-D
230 V~ 50/60 Hz 50 mA
www.lutron.com +44.(0)20.7680.4481
1 2
3
4
Outputs 230 V~ 10 AX each
Zone 1Zone 2Zone 3Zone 4
Option
L
N
µ
Z096
Opt3
CCI
CCI
COM
0,5 N•m
All Others
8 mm
1,2 N•m
Mains Only
Input
Hi Temp
Program
Power
H
M
L
Zones
0-10 V-
50 mA
Up
N
L
Live
Neutral
Switched
Live
Zone1
example
SwitchedOutputs:
230 V
Load
N
L
– Earth/Ground
– Neutral
– Mains/Live
Distribution
Panel
5
®
SPECIFICATION SUBMITTAL Page
Job Name:
Job Number:
Model Numbers:
Switching/0-10 V Power Module LQSE-4 Switching / 0-10 V Fixture Controller
369610a 6 07.18.12
Wiring: 0-10 V
0-10 V Wiring
(LQSE-4T10-D only)
•0-10Vzones1-4aredouble-insulatedfromallother
inputs and outputs.
•0-10Vzones1-4arenotinsulatedfromeachother.
They share the same common (negative “–”
terminal).
•ConnectonlySELV/IECPELVcircuits,orconnectonly
non-SELV/IECPELVcircuitsto0-10Vzones1-4.Do
notmixSELV/IECPELVcircuitsandnon-SELV/IEC
PELV circuits.
•Followallnationalandlocalelectricalcodesfor
separation requirements.
MUX
COM
MUX
QS
Def
Opt1
Opt2
0-10 V Power Module
LQSE-4T10-D
230 V~ 50/60 Hz 50 mA
www.lutron.com +44.(0)20.7680.4481
1 2
3
4
Outputs 230 V~ 10 AX each
Zone 1Zone 2Zone 3Zone 4
Option
L
N
µ
Z096
Opt3
CCI
CCI
COM
0,5 N•m
All Others
8 mm
1,2 N•m
Mains Only
Input
Hi Temp
Program
Power
H
M
L
Zones
0-10 V-
50 mA
Up
Zone 1 Zone 2 Zone 3 Zone 4
+ - + - + - + -
0-10 V Wiring
Wiring: Manual Override Contact Closure Input
IEC PELV Manual Override Contact Closure Input
•ContactClosureInput(CCI)wiringisIECPELV.Follow
all applicable national and local codes for proper
circuit separation and protection.
•WheninManualOverridemode,allballastsand
moduleswillbeattheirprogrammedManualOverride
lightlevel(defaultis100%).Allothercontrolsare
lockedout.
•ManualOverridecontactclosureinputisnormally
closed (NC). The Power Module unit is shipped with a
jumperpre-installed.
Note: The Power Module unit will default to Manual
OverrideModeiftheCCIisleftopen.IfnoManual
Override contact input is required, please leave the
wirejumperintheCCIterminals.
MUX
COM
MUX
QS
Def
Opt1
Opt2
0-10 V Power Module
LQSE-4T10-D
230 V~ 50/60 Hz 50 mA
www.lutron.com +44.(0)20.7680.4481
1 2
3
4
Outputs 230 V~ 10 AX each
Zone 1Zone 2Zone 3Zone 4
Option
L
N
µ
Z096
Opt3
CCI
CCI
COM
0,5 N•m
All Others
8 mm
1,2 N•m
Mains Only
Input
Hi Temp
Program
Power
H
M
L
Zones
0-10 V-
50 mA
Up
CCI Common
6
®
SPECIFICATION SUBMITTAL Page
Job Name:
Job Number:
Model Numbers:
Switching/0-10 V Power Module LQSE-4 Switching / 0-10 V Fixture Controller
369610a 7 07.18.12
Wiring: QS Link
IEC PELV QS Link Wiring
•LinkcommunicatesusingIECPELVwiring.
•Followallapplicablenationalandlocalcodesfor
proper circuit separation and protection.
•Wiringmaybedaisychainedort-tapped.
•TotallengthofQSlinkmustnotexceed600m.
•WireGauge:
Power (terminals 1 and 2): 1 pair 1,0 mm
2
Data (terminals 3 and 4): 1 pair 0,5 mm
2
to
1,0 mm
2
, twisted and shielded.
—CanuseLutroncableGRX-CBL-346S-500
•DoNOTconnectterminal2.
MUX
COM
MUX
QS
Def
Opt1
Opt2
0-10 V Power Module
LQSE-4T10-D
230 V~ 50/60 Hz 50 mA
www.lutron.com +44.(0)20.7680.4481
1 2
3
4
Outputs 230 V~ 10 AX each
Zone 1Zone 2Zone 3Zone 4
Option
L
N
µ
Z096
Opt3
CCI
CCI
COM
0,5 N•m
All Others
8 mm
1,2 N•m
Mains Only
Input
Hi Temp
Program
Power
H
M
L
Zones
0-10 V-
50 mA
Up
(1) COM
(2)
(no connection)
(3) MUX
(4) MUX
7