SPECIFICATION SUBMITTAL Page
Job Name:
Job Number:
Model Numbers:
Vive
PowPak Dimming Module Wireless Lighting Control
3691045c 2 11.16.17
Specifications
Regulatory Approvals
• CE (European Union)
Power
• Operating voltage
220 –240V~ 50 / 60Hz
Output Ratings
• Switch rating of 8 A. Rated for resistive or capacitive
loads as defined by IEC/EN 60669-2-1
• 0 –10V- control link for 60 mA maximum output,
source or sink automatically configures
Other Power Specifications
• Standby power:
220–240 V~ <1.0 W
• BTU / hour when fully loaded: 9
• Works with all drivers and ballasts that provide
a current source that is compliant to IEC 60629
AnnexE.2, and whose inrush current does not
exceed NEMA410 standards for electronic
driver / ballast
System Communication
• Operates using Clear Connect RF Technology for
reliable wireless communication; refer to model
number chart on page 1 for frequency band details
• Wireless sensors and controls must be located within
9 m of the associated control module.
Metal Ceiling Tile Mounting
• Metal ceiling tile grids must have a > 3 mm gap of
non-metallic material which extends the entire length
of the tile on at least one edge. This is often achieved
by foam spacers that are used to prevent tile-to-tile
rattling.
• Metal ceiling tile grids which are continuous (with no
gap) or those that are interlocked, must have a total
surface area that is less than 81 m
2
for each section.
The overall space can be larger as long as there are
non-metallic sections bordering or intersecting the
metal sections.
Environment
• Ambient operating temperature: 0°C to 40°C
• 0% to 90% humidity, non-condensing
• For indoor use only
• All drivers and ballasts used with Vive wireless
controls must comply with EN 55015 / CISPR 15
0 –10V- Control Link
• Communicates with up to 60 mA of fixtures
• Control link is IEC SELV
• 0 –10V- control can be installed using basic or
double-insulated devices
• Terminals accept one 0.75 mm
2
to 1.5mm
2
(18 AWG to 16AWG) solid wire
• Always follow local wiring codes
• Compatible with ANSI E1.3 2001 (R2006), IEC
60929 Annex E
Default Operation
• Associated wireless input devices control all
connected fixtures together
• Occupancy Sensors:
– Occupied:100%; Unoccupied:0% (OFF)
• Pico Remote Controls:
– On:100%; Favorite Level:50%; Off:0% (OFF)
• Daylight Sensor: Decreases electric light in response
to additional available daylight
Key Design Features
• LED status indicator shows load status and provides
programming feedback
• Configurable high-end and low-end trim
• Power failure memory: If power is interrupted,
connected loads will return to the previous level prior
to interruption
• 0 –10V- control mis-wire protection up to 30V-