TENT/MEMBRANE STRUCTURE CHECKLIST Cont…
Open flames and other devices emitting flame, fire, heat or flammable
or combustible liquids, gas,
charcoal or other cooking devices will be
maintained at least (20 feet) away from tent. (This excludes food
warming devices such as solid flammables, butane or other similar
devices which do not cause an ignition
hazard.
Cooking and Heating Equipment shall be more than (10 feet) from exits
and combustible material
Fire Extinguishers shall be located within (75 feet) of all points within
the tent structure
Combustible vegetation shall be moved to a distance of (30 feet) from
the area to be occupied by the tent
Accessibility fixtures, including an accessible walking surface to
accommodate persons with as disability.
(Note
-
Grass is not an
accessible walking surface)
Tent I membrane structure shall be maintained in good condition and
adequately roped, braced and anchored to withstand the elements of
weather and prevent collapse. Ropes, guy wires, etc. must be
readily
visible to minimize a tripping hazard.
Restroom accommodations for the event. Indicate the location(s) and
type(s) (i.e. portable or in buildings) on the site plan. Location:
Certificate of Flame Resistance
Dimension Site plan showing tent location. (20-foot clearance from other
structures and Fire Department
vehicular access to within (150 feet.)
APPLICANT AFFIDAVIT
I, the undersigned, do hereby certify that I have full legal right to request such action and that the statements
or information made in any paper or plans submitted herewith are true and correct to the best of my
knowledge. I understand this application, related material and all attachments become official records of
the Town of Clayton, North Carolina, and will not be returned.
_______________________ __________________________ _____________
Print Name Signature of Applicant Date