JOHN GRABLE,
FAIA
REVISIONS:
SHEET NO.
CHECKED:
DATE:
APPROVED:
PROJECT ADDRESS
DRAWN:
p 210 820 3332 f 210 820 3334 w johngrable.com
San Antonio, TX 78209
222 Austin Highway #1
A R C H I T E C T S - I N C .
ABCDEFGHIJKLM
1
2
3
4
5
6
7
8
MLK
J
IHGFEDCBA
8
7
6
5
4
3
2
1
99
NOTES:
VICINITY MAP
PROJECT DIRECTORY
SHEET INDEX
STORAGE
STAIR, STRINGER
STORM DRAIN
STRUCTURAL
TEXAS ACCESSIBILITY STANDARDS
TELEPHONE
TELEVISION
THICK (NESS)
TONGUE AND GROOVE
TOP OF PLATE
TOP OF STEEL
TOP OF WALL
TREAD, TEMPERED
WATERPROOF
WATER CLOSET
WATER HEATER
WAINSCOT
VERTICAL
UNLESS NOTED OTHERWISE
TYPICAL
WOOD
WITHOUT
WITH
WINDOW
WEST
WELDED WIRE FABRIC
STOR.
STR.
SD
STRUCT.
TAS
TEL.
TV
THK.
T&G
T.O.P.
T.O.S.
T.O.W.
T.
WP.
W/C
WH
WSCT.
VERT.
UNO
TYP.
WD.
W/O
W/
WIN., WIND.
W
WWF
INCLUDED
INCL.
ID INTERIOR DESIGN
INSUL. INSULATION
INT.
INTERIOR
M.C.
MED.
MECH.
MAX.
MSRY.
LAV.
LAM.
MEDICINE CABINET
MEDIUM
MECHANICAL
MAXIMUM
MASONRY
LAVATORY
LAMINATE
ABV.
ABOVE
A.F.F. ABOVE FINISHED FLOOR
ADJ.
ADJUSTABLE
A/C AIR CONDITIONING
ALT.
ALTERNATE
ALUM. ALUMINUM
A.B.
ANCHOR BOLT
A.J.
ARCHITECTURAL JOINT
ARCH.
ARCHITECT (URAL)
ASPH.
ASPHALT
BOTH SIDES
BOARD
BLOCKING
BLOCK (ING)
BETWEEN
BELOW
BENCH MARK
BEAM
BEARING
B.S.
BD.
BLKG.
BLK. (G)
BTWN.
BEL.
B.M.
BM.
BRG.
CATCH BASIN
CAST IRON
CASEMENT
CABINET
BUILDING
BOTTOM OF DECK
BOTTOM OF BEAM
BOTTOM
BOTH WAYS
C.B.
C.I.
CSMT
CAB.
BLDG.
B.O.D.
B.O.B.
BOT.
B.W.
CIRCLE
CERAMIC TILE
CEMENT PLASTER (PORTLAND)
CEMENT
CEILING
CIR.
C.T., CER.
CPPL.
CEM.
CLG., CEIL.
ANODIZEDANOD.
ADA AMERICANS WITH DISABILITIES ACT
BIT.
BITUMINOUS
B.O.S. BOTTOM OF STEEL
BUILT UP
BU
CIRC. CIRCLULAR, CIRCUMFERENCE
CLR. CLEAR
COL.
COLUMN
COMB. COMBINATION
CONC. CONCRETE
CMU
CONCRETE MASONRY UNIT
CONST. CONSTRUCTION
CONT. CONTINUOUS, CONTINUE
CONTRACTORCTR.
CONTROL JOINT
C.J.
COUNTERTOPCNTR.
DEEP
D.
DEMOLISH, DEMOLITIONDEMO
DETAILDTL.
DIAGONALDIAG.
DIAMETER
DIA.
DIMENSIONDIM.
DOOR
DR.
DOUBLE HUNG
D.H.
DOUBLEDBL.
DOWNSPOUT
DS
DISPENSERDISP.
DRAWERDWR.
DRAWING
DWG.
EAST
ELEC. ELECTRIC (AL)
ELEV. ELEVATION
ELV. ELEVATOR
EXIST. EXISTING
EPS
EQ.
EQUAL
EMERG. EMERGENCY
FINISHED FLOORFIN. FLR.
FINISH (ED)FIN.
FIRE EXTINGUISHER CABINETFEC
EXTERIOR INSULATION FINISH SYSTEME.I.F.S.
EXPANSION JOINTEXP. JT.
EXPOSEDEXP.
EXHAUST
EX.
FOOT (FEET)
FT.
FREEZERFRZR.
FIBERGLASS REINFORCED PANELFRP
FLUORESCENTFLUOR.
FLOOR DRAINFD
FLOOR (ING)FLR.
FIREPLACE
FP
GYPSUM WALL BOARDGYP. BD.
GLASSGL.
GENERAL CONTRACTORG.C.
GALVANIZEDGALV.
GAGE, GAUGE
GA.
FOUNDATIONFOUND.
FOOTING
FTG.
HEIGHTHGT., HT.
HEAVY DUTY
H.D.
HEATING/VENTILATION/AIR CONTITIONINGHVAC
HEADERHDR.
HARDWAREHDWR.
HANDICAPPEDH/C
GYPSUMGYP.
INCANDESCENTINCAND.
HOSE BIBBHB
HORIZONTALHORIZ.
HOLLOW METAL
HM
HOLLOW COREHC
HIGH
H.
IN. INCHES
STL.
STD.
SS
SQ.
SPEC.
SP.
S
SC
SIM.
SHLV.
SHT.
SEC., SECT.
SCHED.
RO
RD
RH
REQ'D
RAG
REFG.
PNL.
PLAS.
NTS
PSI
PROP.
R.
REF.
REFL.
OD
PTD.
PANEL
PERF.
P. LAM.
PL.
PLYWD.
PVC
POLYISO
MIN.
MISC.
NOM.
N
NIC
OC
OH
OPG.
OPP.
M.
MEMB.
MBR.
STEEL
STANDARD
STAINLESS STEEL
SQUARE
SPECIFICATION, SPECIFIED
SPACES
SOUTH
SOLID CORE
SIMILAR
SHELVING
SHEET
SECTION
SCHEDULED
ROUGH OPENING
ROOF DRAIN
RIGHT HAND
REQUIRED
RETURN AIR GRILLE
REFRIGERATOR
PANEL
PLASTER
NOT TO SCALE
POUNDS PER SQUARE INCHES
PROPERTY LINE
RADIUS
REFER (ENCE)
REFLECTED
OUTSIDE DIAMETER
PAINTED
ELECTRICAL PANELBOARD
PERFORATED
PLASTIC LAMINATE
PLATE
PLYWOOD
POLYVINYL CHLORIDE
POLYISOCYANURATE BOARD
MINIMUM
MISCELLANEOUS
NOMINAL
NORTH
NOT IN CONTRACT
ON CENTER (S)
OPPOSITE HAND
OPENING
OPPOSITE
METER (S)
MEMBRANE
MEMBER
EXPANDED (EXTRUDED) POLYSTYRENE BOARD
E
ABBREVIATIONS
1/A501
1
2
3
4
A500
RM#
ROOM
1
A
A600
1
A900
1
A400
DR#
#
1
INTERIOR ELEV. NUMBER
DRAWING SYMBOLS
DOOR NUMBER
WINDOW NUMBER
ELEVATION MARK
REVISION NUMBER
ROOM NAME
DETAIL KEY
DETAIL NO.
WALL TYPE
SHEET NO.
HT. ABOVE REF. ELEV. (0'-0")
ROOM NO.
INT. ELEV. NO.
SHEET NO.
SHEET NO.
EXTERIOR ELEV. NO.
SECTION NO.
SHEET NO.
CLIENT INFO:
ARCHITECT INFO:
BUILDER INFO:
STRUCTURALENGINEER INFO:
NOTE:
All drawings and written
material appearing herein
constitute original and
unpublished work of the
architect and may not be
duplicated, used or
disclosed without the
written consent of the
architect
John Grable Architects
222 Austin Highway #1
San Antonio, TX 78209
p. 210.821.3332 e. info@johngrable.com
www.johngrable.com
---
---
---
Beiker Engineering
2702 TX 1604 Loop
San Antonio, TX 78232
City of Alamo Heights
6116 Broadway St
Alamo Heights, TX 78209
____ COVER SHEET 09/11/18
A000 INDEX SHEET 09/11/18
A001 SPECIFICATIONS 09/11/18
A002 SPECIFICATIONS 09/11/18
A003 FLOOR PLAN - CUT AWAY 05/29/18
A004 FLOOR PLAN - CUT AWAY 09/09/18
A005 FLOOR PLAN - CUT AWAY 05/29/18
A100 SITE PLAN - AS BUILT 09/11/18
A101 SITE PLAN - PROPOSED 09/11/18
A200 FLOOR PLAN - AS BUILT 09/11/18
A201 FLOOR PLAN - PROPOSED 09/09/18
A202 FLOOR PLAN - PROPOSED 09/11/18
A220 ENLARGED ARCHITECTURAL FLOOR PLANS 09/11/18
A221 FLOOR PLAN - ACCESSABILITY 09/11/18
A290 DOOR SCHEDULE - PROPOSED 09/04/18
A300 BUILDING SECTIONS - AS BUILT 09/11/18
A301 BUILDING SECTIONS - PROPOSED 09/11/18
A400 EXTERIOR ELEVATION - AS BUILT 09/11/18
A401 EXTERIOR ELEVATION - PROPOSED 09/11/18
A600 DETAILS 09/11/18
A700 INTERIOR ELEVATIONS 09/11/18
A701 INTERIOR ELEVATIONS 09/11/18
A930 FRAMING PLANS - AS BUILT 09/11/18
A931 FRAMING PLANS - PROPOSED 09/11/18
A940 ROOF PLAN - AS BUILT 09/11/18
A941 ROOF PLAN - PROPOSED 09/11/18
D100 DEMOLITION PLAN 09/11/18
E100 RCP & ELECTRICAL - AS BUILT 09/11/18
E101 RCP & ELECTRICAL - PROPOSED 09/11/18
P100 PLUMBING LOCATION PLAN - AS BUILT 09/11/18
P101 PLUMBING LOCATION PLAN - PROPOSED 09/11/18
**ARCHITECTURAL DRAWINGS AND SPECS AS INSTRUMENTS OF SERVICE ARE AND SHALL REMAIN EXCLUSIVE PROPERTY OF THE ARCHITECT WHETHER THE PROJECT FOR WHICH THEY ARE
MADE IS EXECUTED OR NOT. ALL DRAWINGS AND WRITTEN MATERIAL APPEARING HEARIN CONSTITUTE ORIGINAL UPUBLISHED WORK OF THE ARCHITECT AND MAY NOT BE DUPLICATED, USED
BY THE OWNER ON OTHER PROJECTS, OR EXTENSIONS TO THIS PROJECT WITHOUT THE WRITTEN CONSENT OF THE ARCHITECT.
ALAMO HEIGHTS
1. THE PROJECT IS COMPLIES THE 2015 INTERNATIONAL CODE SERIES, AS ADOPTED BY THE CITY OF ALAMO HEIGHTS, AND WITH THE CODE OF ORDINANCES OF THE CITY OF ALAMO HEIGHTS.
2. MUST MEET 2012 TAS ACCESSIBILITY STANDARDS.
3. BACKFLOW PREVENTION DEVICES ON INDIVIDUAL PIECES OF EQUIPMENT (AS INDICATED IN TCEQ REGULATIONS), ON FIRE SPRINKLER SYSTEM (IF NEWLY INSTALLED OR UPGRADED
SYSTEM), AND ON WATER SERVICE FROM CITY MAIN.”
4. VACUUM BREAKER DEVICES SHALL BE INSTALLED ON ALL EXTERIOR HOSE BIBS.
5. PROPERTIES FRONTING ALONG BROADWAY AND/OR AUSTIN HIGHWAY SHALL INSTALL SIDEWALKS CONSTRUCTED PER THE CITY OF SAN ANTONIO FLATWORK CONSTRUCTION HANDBOOK
AND SHALL BE ADA COMPLIANT REGARDING SLOPES AND RAMPS.
6. FIRELINES TO FIRE HYDRANTS AND/OR FIRE PROTECTION SPRINKLER SYSTEMS, SHALL BE TAPPED INDEPENDENT OF DOMESTIC WATER LINE.
7. WATER METER INSTALLATIONS SHALL BE IN ACCORDANCE WITH SAN ANTONIO WATER SYSTEM STANDARDS.
ELECTRICAL NOTES
THE ELECTRICAL CONTRACTOR SHALL PROVIDE A FULLY ENGINEERED SYSTEM TO INCLUDE ANY AND ALL REQUIRED DESIGN DOCUMENTS, PROFESSIONAL SEAL, USER DIAGRAMS AND
MATERIAL LIST AS REQUIRED BY THE LOCAL GOVERNING AUTHORITY.
THE ELECTRICAL CONTRACTOR SHALL COORDINATE HIS WORK WITH THE WORK OF OTHER TRADES AND HAVE HIS WORK SCHEDULED SO AS NOT TO DELAY THE WORK OF OTHERS.
THE CONTRACTOR SHALL BE RESPONSIBLE FOR INSPECTION AND APPROVAL OF WIRING, INSTALLATION OF FIXTURES AND EQUIPMENT, AND FOR FINAL ACCEPTANCE OF THE
COMPLETE ELECTRICAL INSTALLATIONS BY THE UNDERWRITER’S OR BY LOCAL ELECTRICAL INSPECTORS.
SERVICE ENTRANCE CONDUCTORS AND EQUIPMENT SHALL BE OF CAPACITY ADEQUATE TO SERVE THE CALCULATED LOAD AND SPARE CIRCUITS PROVIDED FOR FUTURE USE.
1. THE SIZE OF SERVICE ENTRANCE CONDUCTORS AND CAPACITY OF SERVICE EQUIPMENT SHALL BE COMPUTED BY METHOD INDICATED IN THE NATIONAL ELECTRIC CODE.
ELECTRICAL SUBCONTRACTOR TO CALCULATE ALL LOADS AS REQUIRED FOR METER LOOP.
CONFIRM ALL APPLIANCE VENTILATION, ELECTRICAL AND PLUMBING REQUIREMENTS WITH MANUFACTURERS SPECIFICATIONS PRIOR TO STUB OUT FOR CONNECTIONS.
CONFIRM ALL UNDER CABINET LIGHT FIXTURE SELECTIONS, AVAILABLE LENGTHS, AND CONFIRM ALL STUB OUT LOCATIONS FOR UNDER CABINET LIGHTING WITH OWNER PRIOR TO
INSTALLATION.
CONFIRM ALL STUB OUT LOCATIONS FOR BACK SPLASH, WALL SCONCE, BATH FIXTURES AND OUTLET LOCATIONS WITH OWNER PRIOR TO INSTALLATION.
PROVIDE ARC FAULT CIRCUIT INTERRUPTION AT THE KITCHEN AND BATH ROOMS.
OWNER’S VENDOR TO PROVIDE CONTROLS TO ALL THERMOSTATS AND EXTERIOR LIGHTING SYSTEMS.
SMOKE DETECTORS SHALL BE ELECTRONICALLY HARDWIRED WITH A BATTERY BACK UP. ALL SMOKE DETECTORS SHALL BE INTERCONNECTED SO THAT IF ONE OF THE UNITS GOES INTO
ALARM, ALL THE UNITS GO INTO ALARM.
PROVIDE 10-YEAR BACKUP BATTERIES ON SMOKE DETECTORS.
PROVIDE 22OV. POWER AT EACH WATER HEATER LOCATION.
PLUMBING NOTES
PROVIDE AND INSTALL FIXTURES AS NOTED ON THE DRAWINGS.
PROVIDE ALL ACCESSORIES, STRAPS, INSULATION AND OTHER MATERIALS REQUIRED FOR COMPLETE INSTALLATION.
FURNISH AND INSTALL A COMPLETE SYSTEM OF SANITARY DRAINAGE, AND VENTING FOR THE PROJECT INCLUDING EXCAVATION, BACKFILL, DRAINAGE LINES, VENTS, VENT STACKS,
RAINWATER CONDUCTORS, BOOTS, TRAPS, ALL NECESSARY CONNECTIONS TO A PUBLIC SEWER LINE OR INDIVIDUAL WASTER DISPOSAL SYSTEM.
FURNISH AND INSTALL A COMPLETE WATER SUPPLY SYSTEM FOR THE PROJECT INCLUDING WATER SERVICE CONNECTION, PIPE LINES, DRAINS, FITTINGS, CONNECTIONS TO PLUMBING
FIXTURES, AND ALL NECESSARY ACCESSORIES TO PROVIDE A COMPLETE WORKABLE INSTALLATION.
THE GENERAL CONTRACTOR AND ALL SUB-CONTRACTORS SHALL BE RESPONSIBLE FOR THE ENFORCEMENT OF ALL REQUIREMENTS AND REGULATIONS AND SHALL PERFORM ALL
WORK ON THIS PROJECT IN COMPLIANCE WITH THE AMERICANS WITH DISABILITIES ACT.
INFORMATION SHOWN ON THIS SHEET IS MINIMUM REQUIRED FOR ADA COMPLIANCE
ALL CONDITIONS SHOWN ON THIS SHEET MAY NOT BE REQUIRED BY THIS PROJECT. COMPARE THE REQUIREMENTS OF THE ARCHITECTURAL DRAWINGS WITH THIS SHEET FOR
RELEVANCE OF INFORMATION.