SPECIFICATION SUBMITTAL Page
Job Name:
Job Number:
Model Numbers:
Dual-Circuit Switch with Occupancy/Partial-On Sensor
369758e 1 06.13.19
Maestro Sensor
MS-OPS6-DDV-XX
1
(Occupancy model
2
)
UMS-OPS6-DDV-XX
1
(Occupancy model
2, 3
)
MS-PPS6-DDV-XX
1
(Partial-ON only model
2
)
UMS-PPS6-DDV-XX
1
(Partial-ON only model
2, 3
)
1
“XX” in the model number represents color/finish code. See Colors and
Finishes at end of document.
2
Wallplate not included.
3
BAA-compliant model number.
Maestro dual-circuit
occupancy sensor switch
The Lutron Maestro dual-circuit occupancy sensor
switch combines two switches with an in-wall, passive
infrared (PIR) occupancy or partial-on sensor. The
sensor is intended for either:
• Control of two circuits
• Bi-level control of two circuits, as required by certain
energy codes (e.g., ASHRAE)
Features
• Passive infrared sensor with exclusive Lutron XCT
Technology for minor motion detection
• 180° sensor field-of-view
• Tamper-resistant PIR lens
• Up to 30 ft x 30 ft (9 m x 9 m) [900 ft
2
(81 m
2
)] major
motion coverage and 20 ft x 20 ft (6 m x 6 m)
[400 ft
2
(36 m
2
)] minor motion coverage
• Smart Ambient Light Detection (ALD) mode uses
adaptive algorithm: Sensor learns the user’s preferred
light level over time
• Occupancy version can be set to Auto-ON / Auto-OFF
or Manual-ON / Auto-OFF
• Meets Title 24 / Title 20 requirements for multi-level
lighting. Partial-ON only (PPS6-DDV) version available
to meet Title 24 / Title 20 requirements for
Partial-ON sensors
• Adjustable timeout for each circuit
(1, 5, 15, or 30 minutes)
• Sensitivity adjustment (High/Low)
• Switches all lighting loads: incandescent, halogen,
ELV, MLV, CFL, LED, magnetic fluorescent,
electronic fluorescent
• Switches fan loads at 120 V~
• Single-pole only
1
SPECIFICATION SUBMITTAL Page
Job Name:
Job Number:
Model Numbers:
Dual-Circuit Switch with Occupancy/Partial-On Sensor
369758e 2 06.13.19
Maestro Sensor
Specifications
Regulatory Approvals
• UL Listed to U.S. and Canadian safety requirements
• Title 20/24 certified lighting control device
Complies with Title 20 and Title 24 Section 119
(Until Jan 1st, 2014)
Complies with Title 20 and Title 24 Section 110.9
(After Jan 1st, 2014)
• NOM Certified
Power / Load Control
120 – 277 V~ 50 / 60 Hz
Key Design Features
• Switches all lighting loads
• 6 A of lighting load per circuit at 120 277 V~
• 4.4 A (1/6 HP) of fan load per circuit at 120 V~
• Crush/tamper resistant lens
• Smart Ambient Light Detection (ALD)
• Adaptive zero-cross switching algorithm for extended
relay life (patent pending)
• XCT Technology for minor motion detection
Environment
• Ambient operating temperature: 32 °F to 104 °F
(0 °C to 40 °C), 0% 90% humidity, non-condensing.
Indoor use only.
Warranty
• 5-Year Limited Warranty. For additional Warranty
information, please visit
www.lutron.com/TechnicalDocumentLibrary/Sensor_
Warranty.pdf
Additional Information
• For single-circuit Maestro occupancy sensor switch
models, please see Lutron P/N 369666
• For Maestro occupancy sensor C
L dimmer models,
please see Lutron P/N 369748
• For more information, please see
www.lutron.com/occvacsensors
• Lutron Customer Support: 1.844.LUTRON1
Advanced Features
Switching
Adaptive zero-cross switching (patent
pending)—maximizes relay life by switching at
the point of minimum energy on the AC power
curve. Actively adapts to variations in
relay timing.
XCT Technology
Advanced sensing technology for minor motion
detection ensures that the lights stay on while
the room is occupied, and that the sensor does
not turn on falsely when there is no occupancy
in the room. For more information, see
www.lutron.com/XCTWhitePaper
2
SPECIFICATION SUBMITTAL Page
Job Name:
Job Number:
Model Numbers:
Dual-Circuit Switch with Occupancy/Partial-On Sensor
369758e 3 06.13.19
Maestro Sensor
* Default settings shown in this section are locked in the MS-PPS6-DDV
(Partial-ON only) to satisfy the CEC 2013 Title 24 definition for a
“Partial-ON” sensor
1
Default setting for circuit 1
2
Default setting for circuit 2
Custom Settings at-a-glance
Circuit 1 Circuit 2
Timeout
Test mode Test mode
1 min 1 min
5 min 5 min
15 min 15 min
30 min 30 min
Sensitivity
High
Low
Sensor
Modes*
Auto-ON/Auto-OFF
(Occupancy)
1
Auto-ON/Auto-OFF
(Occupancy)
Manual-ON/Auto-OFF
(Partial-ON)
Manual-ON/Auto-OFF
(Partial-ON)
2
Advanced
Auto-ON
Modes
Ambient Light Detection (ALD)
Off-While-Occupied Enabled (OWO)
Off-While-Occupied Disabled
Custom Settings
(defaults shown in Bold)
Timeout (applies to individual circuits)
– Test mode
– 1 min
– 5 min
15 min
– 30 min
Sensor Modes* (apply to individual circuits)
Auto-ON / Auto-OFF
1
(Occupancy mode)
Manual-ON / Auto-OFF
2
(Partial-On mode)
Advanced Auto-ON Modes (apply to all
Auto-ON circuits)
– Ambient Light Detection (ALD) mode:
· Lights turn on only when natural light in the
room is low
· Smart-Ambient light threshold adjusts to the
user’s preference
Off-While-Occupied Enabled (OWO)
· When the occupancy sensor switch is manually
turned off, the occupancy sensor switch will not
turn the lights back on automatically while the
room is occupied.
· Once the room is vacated, the Auto-ON feature
returns to normal operation after the timeout
period has expired.
· This may be the preference in conference
rooms or classrooms while viewing
presentations.
– Off-While-Occupied Disabled
· When the occupancy sensor switch is manually
turned off, the Auto-ON feature will return to
normal operation after 25 seconds.
· When the unit is manually turned off, after 25
seconds the unit will turn back on if motion
is detected.
· This setting may be the preference for
high-traffic areas where it is important to ensure
that the lights always respond to occupancy
(e.g., bathroom, laundry room, utility closet).
Sensitivity (applies to both circuits)
High sensitivity
– Low sensitivity
– Restore ALL defaults
3
SPECIFICATION SUBMITTAL Page
Job Name:
Job Number:
Model Numbers:
Dual-Circuit Switch with Occupancy/Partial-On Sensor
369758e 4 06.13.19
Maestro Sensor
Load Type and Capacity
Control Voltage Load Type
Minimum
Load
Maximum Load
(Anywhere in Gang)
MS-OPS6-DDV
UMS-OPS6-DDV
MS-PPS6-DDV
UMS-PPS6-DDV
120 V~
Lighting
1, 2
0 A
6 A per circuit
Fan
2
4.4 A (1/6 HP) per circuit
120–277 V~ Lighting
1
6 A per circuit
1
Occupancy sensor switch Load Type: designed for use with permanently installed incandescent, halogen, MLV, ELV, CFL, LED, magnetic fluorescent, and
electronic fluorescent lighting loads.
2
When controlling light and fan loads simultaneously on a single circuit, maximum load capacity per circuit is 4.4 A at 120 V~.
Notes:
– Ground or neutral is required for product to function. If neither wire is present, consult a licensed electrician.
– Connect green-sleeved wire to ground only in retrofit and replacement applications. When neutral connection
is available, remove green sleeve and connect to neutral.
4
SPECIFICATION SUBMITTAL Page
Job Name:
Job Number:
Model Numbers:
Dual-Circuit Switch with Occupancy/Partial-On Sensor
369758e 5 06.13.19
Maestro Sensor
Horizontal Beam Diagram
(for reference only)
5 ft
(1.5 m)
5 ft
(1.5 m)
0
10 ft
(3 m)
10 ft
(3 m)
15 ft
(4.5 m)
15 ft
(4.5 m)
20 ft
(6 m)
20 ft
(6 m)
25 ft
( 7.5 m)
25 ft
( 7.5 m)
30 ft
(9 m)
30 ft
(9 m)
Vertical Beam Diagram
5 ft
(1.5 m)
10 ft
(3 m)
15 ft
(4.5 m)
20 ft
(6 m)
25 ft
( 7.5 m)
30 ft
(9 m)
4 ft
(1.2 m)
0
Occupancy sensor switch placement and operation
• The ability of the occupancy sensor switch to detect motion requires line-of-sight of room occupants. The
occupancy sensor switch must have an unobstructed view of the room.
• Hot objects and moving air currents can affect the performance of the occupancy sensor switch. Switch
performs best when located 4 ft (1.2 m) or more away from hot objects or moving air currents.
• The performance of the occupancy sensor switch depends on a temperature differential between the ambient
room temperature and that of room occupants. Warmer rooms may reduce the ability of the occupancy sensor
switch to detect occupants.
Definitions
Major motion: movement of a person entering or passing through an area.
Minor motion: movement of a person occupying an area and engaging in small activities (e.g., reaching for a
telephone, turning the pages of a book, opening a file folder, picking up a coffee cup).
0 10 ft
(3 m)
15 ft
(4.5 m)
20 ft
(6 m)
25 ft
( 7. 5 m )
30 ft
(9 m)
5 ft
(1.5 m)
5 ft
(1.5 m)
0
10 ft
(3 m)
10 ft
(3 m)
15 ft
(4.5 m)
15 ft
(4.5 m)
5 ft
(1.5 m)
NEMA WD7 Coverage
Major motion coverage: 900 ft
2
(81 m
2
)
Minor motion coverage: 400 ft
2
(36 m
2
)
Test Room Dimensions: 37 ft x 38 ft (11.28 m x 11.6 m)
Test Floor Surface Material: Carpet
Sensor Coverage Angle: 180°
Major motion coverage: Initial trigger motion detection
Minor motion coverage: Maintained motion detection
5
SPECIFICATION SUBMITTAL Page
Job Name:
Job Number:
Model Numbers:
Dual-Circuit Switch with Occupancy/Partial-On Sensor
369758e 6 06.13.19
Maestro Sensor
Dimensions
Measurements shown as: in (mm).
Front View
Side View
4
11
16
(119)
2
15
16
(75)
1
1
8
(30)
5/16 (8)
1/8 (3)
Mounting
Wallbox Occupancy sensor switch Wallplate Adapter / Wallplate
(sold separately)
Mounting screws Adapter mounting screws
Operation
Sensor lens
Top tap button
controls circuit 1
(tap on / off)
Top
programming
button
Bottom
programming
button
Bottom tap button
controls circuit 2
(tap on / off)
Sensor LED (behind lens)
Pulses during configuration
of custom settings and in
the Test mode.
6
SPECIFICATION SUBMITTAL Page
Job Name:
Job Number:
Model Numbers:
Dual-Circuit Switch with Occupancy/Partial-On Sensor
369758e 7 06.13.19
Maestro Sensor
Wiring Installations with the Maestro Dual-Circuit Sensor
In order to function, the Dual-Circuit Sensor must have the green-sleeved wire connected to ground, or the white
wire connected to neutral. Before installing wallplate, program all desired settings.
Hi
Med
Low
Min
PIR
Alt
m30
15
5
1
Occ
Lrn
Fixd
Vac
Mode
120 – 277 V~
50 / 60 Hz
8 A
TURN OFF POWER
ARRETEZ LE COURANT
DESCONECT LA CORRIENTE
Up
Coopersburg, PA
800.523.9466
lutron.com
White wire covered
by green sleeve
connects to ground
White wire connects to neutral
7
SPECIFICATION SUBMITTAL Page
Job Name:
Job Number:
Model Numbers:
Dual-Circuit Switch with Occupancy/Partial-On Sensor
369758e 8 06.13.19
Maestro Sensor
Wiring
1
When neutral is present in wallbox, remove green sleeve from the white wire and connect the white wire to neutral.
2
If no neutral is present, connect green-sleeved wire to ground.
Single-Line Wiring with Neutral
120–277 V~
Neutral
Black Black
Load 1
Load 2
Bare copper
White
1
Striped Striped
Single-Line Wiring without Neutral
120–277 V~
Neutral
Black Black
Load 1
Load 2
Bare copper
Striped Striped
Note: Ground connection required for functionality
Green-sleeved wire
2
8
SPECIFICATION SUBMITTAL Page
Job Name:
Job Number:
Model Numbers:
Dual-Circuit Switch with Occupancy/Partial-On Sensor
369758e 9 06.13.19
Maestro Sensor
1
When neutral is present in wallbox, remove green sleeve from the white wire and connect the white wire to neutral.
2
If no neutral is present, connect green-sleeved wire to ground.
Two-Line Wiring with Neutral*
Line 1: 120–277 V~
Neutral 2
Black Black
Load 1
Load 2
Bare copper
White
1
Line 2: 120–277 V~
Neutral 1
Striped Striped
*
Wiring must comply with 2011 NEC code 210.7 for wiring Multiple Branch Circuits: Where two or more branch circuits supply devices or equipment on the
same yoke, a means to simultaneously disconnect the ungrounded conductors supplying those devices shall be provided at the point at which the branch
circuits originate.
Two-Line Wiring without Neutral*
Line 1: 120–277 V~
Neutral 2
Black Black
Load 1
Load 2
Bare copper
Green-sleeved wire
2
Line 2: 120–277 V~
Neutral 1
Striped Striped
Note: Ground connection required for functionality
*
Wiring must comply with 2011 NEC code 210.7 for wiring Multiple Branch Circuits: Where two or more branch circuits supply devices or equipment on the
same yoke, a means to simultaneously disconnect the ungrounded conductors supplying those devices shall be provided at the point at which the branch
circuits originate.
9
SPECIFICATION SUBMITTAL Page
Job Name:
Job Number:
Model Numbers:
Dual-Circuit Switch with Occupancy/Partial-On Sensor
369758e 10 06.13.19
Maestro Sensor
Colors and Finishes
Due to printing limitations, colors and finishes
shown cannot be guaranteed to match actual
product colors perfectly.
• Color chip keychains are available for more
precise color matching:
Gloss Finishes: DG-CK-1
Satin Finishes: SC-CK-1
Satin Finishes
Taupe
TP
Plum
PL
Merlot
MR
Terracotta
TC
Sienna
SI
Midnight
MN
Hot
HT
Desert Stone
DS
Eggshell
ES
Biscuit
BI
Snow
SW
Palladium
PD
Greenbriar
GB
Bluestone
BG
Mocha Stone
MS
Goldstone
GS
Stone
ST
Limestone
LS
Gloss Finishes
White
WH
Ivory
IV
Almond
AL
Light Almond
LA
Gray
GR
Brown
BR
Black
BL
For the latest color offerings please see our website:
http://www.lutron.com/satincolors
)Lutron, Lutron, Maestro, XCT and C•L are trademarks or registered trademarks of Lutron Electronics Co., Inc. in the US and/or other countries.
UL is a trademark of UL LLC.
NEC is a registered trademark of National Fire Protection Association, Quincy, Massachusetts.
10