Vive Wireless Receptacle With Clear Connect Technology Wireless Receptacle Control
3691034d 2 11.29.18
Specifications
Regulatory Approvals
•cULus498B-SA;ListedwithFederalSpecicationWC596
•FCCapproved.ComplieswiththelimitsforaClassB
device, pursuant to Part 15 of the FCC
•IndustryCanada
•NOMandIFT(Mexico)
•ASHRAE90.1compliantwhenusedwithwireless
transmitters or the Vive wireless hub
• CECTitle24compliantwhen used with wireless
transmitters or the Vive wireless hub
• NEMA
® WD-6 compliant
Power
•Operatingvoltage:
120 V ~
50 / 60Hz
System Communication
•OperatesusingClearConnectRFTechnologyforreliable
wireless communication.
•RFrangeis60ft(18m)lineofsight,or30ft(9m),
through walls. For maximum RF range do not place large
office furniture in front of wireless receptacles.
Environment
•Ambientoperatingtemperature:32˚Fto122˚F
(0˚Cto50˚C)
•0%to90%humidity,non-condensing
•Forindooruseonly
Terminals
•Eachterminalacceptsuptotwo14AWGto12AWG
(1.5mm
2
to4.0mm
2
) wires
•Sideorbackwireinstallationcapable
•Solidorstrandedwires
•Copperwiresonly
Switching
•Adaptivezerocross—maximizesrelaylifebyactively
adapting to variations in relay timing to switch at the
point of minimum energy on the AC power curve.
Load
•Availablein15Aor20Avarieties.Seechartbelow
for maximum load ratings.
•Nominimumloadrequirements.
•
The Wireless Receptacle may be used with, but is
notlimitedto,thefollowing:
–Monitors –Fans –Humidiers
Note: Refer to the manufacturer’s guidelines for
acceptable switching methods.
•
TheWirelessReceptacleisNOTsuitableforuse
withdevicesthatrequireanyofthefollowing:
– Shut-down process before power is interrupted,
such as computers.
– Cool-down process before power is interrupted,
such as projectors.
– Programming, such as clocks or DVRs.
– Long warm-up cycle.
•
Ensure that the equipment being controlled
is visible from every control location and that
only suitable equipment is connected to these
controls.
•
Not for use with loads that present a hazard if
automatically energized. For example, heaters.
•
Any receptacles that are controlled by an
automatic control device must be marked with
“ u” located on the controlled receptacle outlet
where visible after installation as stated in 2014
NECR Article 406.3(E).
NOTE: Labels with this marking “u”
are included
with the product.
Mounting
•TypicalU.S.stylewallboxdimensions:
3.0in(76mm)Hx2.0in(51mm)Wx
2.5 in (64 mm) D
Load Type
Relay Ratings
120 V~ 15 A single phase only
CAR2S-15-STR, CAR2S-15-DTR
120 V~ 20 A single phase only
CAR2S-20-STR, CAR2S-20-DTR
Tungsten 1000 W 1500 W
L E D / C F L 3.75 A 5 A
ACGeneralUse 15 A 20 A
Resistive 15 A 20 A
Inductive 15 A 20 A
Motor
0.5HP120V~ 1.0HP120V~