SPECIFICATION SUBMITTAL Page
Job Name:
Job Number:
Model Numbers:
Power Module with EcoSystemR LQSE-2ECO-D EcoSystemR Controller
369611b 1 10.22.13
MUX
COM
MUX
QS
ECO 1 ECO 2
Test
Prueba
Tester
Ta > 65 ºC
LN
Patent: 7,391,297
500-15537 Rev. A
NEC®
Class 2
NEC
® Class 2
IEC PELV
0,5 N•m (5 in-lbs)
Ta ≤ 65 °C
www.lutron.com
u
Z096
65/75 ºC
Cu
Al
Power Module with EcoSystem
®
| Módulo de Potencia con EcoSystem
®
| Module d’Alimentation avec EcoSystem
®
LQSE-2ECO-D
243C IND.CONT.EQ.
8 mm
1.800.523.9466
+44.(0)20.7702.0657230 V~ 50/60 Hz 80 mA
120 V~ 50/60 Hz 120 mA
Power Module with EcoSystemR
The Power Module with EcoSystemR unit is a
DIN-rail mounted EcoSystem
® Loop controller for
EcoSystemR ballasts, drivers and devices. It
provides EcoSystemR Loop power and control for
two independent EcoSystemR Loops with up to 64
ballasts or drivers each.
Features
Provides EcoSystemR Loop power for two loops
of EcoSystemR ballasts or drivers (up to 250 mA
per loop).
Power failure memory retains control unit
programming in the event of a power loss.
Includes QS Link for connection to a
HomeWorksRQS system.
Power Module with EcoSystemR unit can be used in
a HomeWorksR QS system to control and manage
light in an entire home or building.
Up to 64
ballasts on
each loop
QS Link
Eco Loop 1
Eco Loop 2
Ballast
Ballast
Power
Module
Power
Module with
EcoSystem®
HomeWorksR QS
Processor
GRAFIK
EyeR QS
QS
Contact
Closure
Interface
HomeWorksR QS
Wallstation
Ballast
Ballast
120 / 230 V~
Control Power
Up to 100
total QS
devices
QS
Power
Supply
SivoiaR QS
Shade / Drapery
System Example
1
®
SPECIFICATION SUBMITTAL Page
Job Name:
Job Number:
Model Numbers:
Power Module with EcoSystemR LQSE-2ECO-D EcoSystemR Controller
369611b 2 10.22.13
Specifications
Power
120 V~ 50/60 Hz 120 mA
230 V~ 50/60 Hz 80 mA
Lightning strike protection meets ANSI/IEEE standard
62.31-1980. Can withstand voltage surges of up to
6000V~ and current surges of up to 3000 A.
Stand by power: 7 W
BTUs / hour when fully loaded: 24
• EcoSystemR Loop Output: 16 V- 250 mA maximum
per loop.
Standards
• UL
• CE
Lutron Quality Systems registered to ISO 9001.2008.
• C-Tick S
• cUL
• NOM
Environment
Surrounding Air Temperature Range: 0 ºC to 65 ºC
(32 ºF to 149 ºF).
Relative humidity: less than 90% non-condensing.
Calibration point maximum: 75 ºC (167 ºF)
For indoor use only.
Terminals
Mains wiring: 1.0 mm
2
to 4.0 mm
2
(18 AWG to 12AWG)
EcoSystemR
Loop Wiring: 1,0 mm
2
to 4,0 mm
2
(18 AWG to 12AWG)
QS Wiring: 1,0 mm
2
(18AWG)
Minimum wire temperature rating = 65 °C (149 ºF),
Cu only
Mounting
Intended to mount within an IP20 (minimum) rated
consumer panel or breaker panel with integrated DIN
rail and dead cover
Width = 9 DIN modules (161.7 mm or 6
3
8 in).
Programming and Compatibility Requirements
The LQSE-2ECO-D can only be used with the
HomeWorksRQS system.
Setup and programming of the Power Module with
EcoSystemR is done through the HomeWorksRQS
programming software.
EcoSystemR
Control up to 64 EcoSystemR-compatible devices
(ballast or LED drivers) per EcoSystemR Digital Loop (up
to 128devices per Power Module with EcoSystemR unit).
Digitally define areas and zones.
Automatic replacement of a single failed ballast or driver.
Simple method of replacing multiple failed ballasts
or drivers.
EcoSystemR Digital Loop can be wired as Mains voltage
or IEC PELV / NECR Class 2 for maximum wiring flexibility.
• EcoSystem® Loop wires are polarity insensitive and
topology-free.
EcoSystemR Digital Loop Limits
Up to 64 EcoSystemR-compatible fluorescent ballasts
and/or LED drivers per EcoSystemR digital loop.
• EcoSystemR-compatible fluorescent ballasts and LED
drivers on the EcoSystemR digital loop do not count as
QS devices.
QS Link Limits
A QS link in a HomeWorks
®QS system can have up
to 512 zones (outputs) and 100devices. A ballast or
driver counts as 1 zone unless specifically grouped
into zones from the HomeWorks
®QS software.
Each Power Module with EcoSystemR unit counts as
one device toward the 100 device limit.
A maximum of 8 fully loaded EcoSystemR digital loops
may be connected to a single QS link.
HomeWorksR QS Wallstations
HomeWorksR QS wallstations can be configured to
control Power Module with EcoSystemR units with the
HomeWorksR QS programming utility.
• LED indicator displays the status of programmed lights.
Troubleshooting and Maintenance
Features
Maintains redundant memory of ballast programming
for ease of single or multiple ballast replacement.
To verify EcoSystem
® lights connected to EcoSystemR
Loop 1 and Loop 2:
Enter Test Mode: Press and hold Test button on
the Power Module with EcoSystemR until the Test
LED starts flashing.
Test: Each press of either the ECO 1 or ECO 2
button will cycle the lights between high-end,
low-end, flash, and off for that loop.
Exit Test Mode: Press and hold Test button
until Test LED stops flashing.
NEC is a registered trademark of the National Fire Protection Association, Quincy, Massachusetts
2
®
SPECIFICATION SUBMITTAL Page
Job Name:
Job Number:
Model Numbers:
Power Module with EcoSystemR LQSE-2ECO-D EcoSystemR Controller
369611b 3 10.22.13
161.7 mm
(6
3
8 in)
60.6 mm
(2
3
8 in)
500-13431 Rev. B
N1771
Z096
89.7 mm
(3
1
2 in)
MUX
COM
MUX
QS
ECO 1 ECO 2
Test
Prueba
Tester
Ta > 65 ºC
LN
Patent: 7,391,297
500-15537 Rev. A
NEC®
Class 2
NEC
® Class 2
IEC PELV
0,5 N•m (5 in-lbs)
Ta ≤ 65 °C
www.lutron.com
u
Z096
65/75 ºC
Cu
Al
Power Module with EcoSystem
®
| Módulo de Potencia con EcoSystem
®
| Module d’Alimentation avec EcoSystem
®
LQSE-2ECO-D
243C IND.CONT.EQ.
8 mm
1.800.523.9466
+44.(0)20.7702.0657230 V~ 50/60 Hz 80 mA
120 V~ 50/60 Hz 120 mA
Overview of Wiring Terminals and Mechanical Dimensions
* Wire according to local codes.
Mains
Wiring
Eco
Loop
1*
Eco
Loop
2*
QS
Link
IEC PELV/
NECR Class 2
NEC is a registered trademark of the National Fire Protection Association, Quincy, Massachusetts
NECR Class 2
3
®
SPECIFICATION SUBMITTAL Page
Job Name:
Job Number:
Model Numbers:
Power Module with EcoSystemR LQSE-2ECO-D EcoSystemR Controller
369611b 4 10.22.13
Wiring: Mains Voltage
Wiring from Distribution to Power Module Unit
• Turn off all circuit breakers or isolators feeding the
Power Module unit at the distribution panel.
• Run line, neutral, and earth/ground wires from a
feed to the Power Module with EcoSystemR.
• Use 1.0 mm
2
to 4.0 mm
2
(18 AWG to 12 AWG)
conductors (depending on breaker rating) to feed
the mains wiring. The device draws less than 80 mA
(230 V~) or 120 mA (120 V~).
Emergency Lighting Applications
• Use normal (non-essential) power only to power the
Power Module with EcoSystemR.
EcoSystemR ballasts and drivers are programmed to
enter emergency mode when the EcoSystemR Loop
loses power.
• When normal power drops out, the Power Module
with EcoSystemR will not power the EcoSystemR
Loops. When this occurs, ballasts powered from
emergency feeds go to their emergency mode, full
light output by default.
Mains Wiring and IEC PELV/NECR Class 2
Separation
• The Power Module with EcoSystemR is designed
to separate mains wiring from IEC PELV / NECR
Class2 circuits.
• Follow appropriate local and national codes to avoid
violating required separation guidelines.
MUX
COM
MUX
QS
ECO 1 ECO 2
Test
Prueba
Tester
Ta > 65 ºC
LN
Patent: 7,391,297
500-15537 Rev. A
NEC®
Class 2
NEC
® Class 2
IEC PELV
0,5 N•m (5 in-lbs)
Ta ≤ 65 °C
www.lutron.com
u
Z096
65/75 ºC
Cu
Al
Power Module with EcoSystem
®
| Módulo de Potencia con EcoSystem
®
| Module d’Alimentation avec EcoSystem
®
LQSE-2ECO-D
243C IND.CONT.EQ.
8 mm
1.800.523.9466
+44.(0)20.7702.0657230 V~ 50/60 Hz 80 mA
120 V~ 50/60 Hz 120 mA
MUX
COM
MUX
QS
ECO 1 ECO 2
Test
Prueba
Tester
Ta > 65 ºC
LN
Patent: 7,391,297
500-15537 Rev. A
NEC®
Class 2
NEC
® Class 2
IEC PELV
0,5 N•m (5 in-lbs)
Ta ≤ 65 °C
www.lutron.com
u
Z096
65/75 ºC
Cu
Al
Power Module with EcoSystem
®
| Módulo de Potencia con EcoSystem
®
| Module d’Alimentation avec EcoSystem
®
LQSE-2ECO-D
243C IND.CONT.EQ.
8 mm
1.800.523.9466
+44.(0)20.7702.0657230 V~ 50/60 Hz 80 mA
120 V~ 50/60 Hz 120 mA
N
L
N
L
Distribution
Panel
– Earth/Ground
– Neutral
– Mains/Line
NEC is a registered trademark of the National Fire Protection Association, Quincy, Massachusetts
4
®
SPECIFICATION SUBMITTAL Page
Job Name:
Job Number:
Model Numbers:
Power Module with EcoSystemR LQSE-2ECO-D EcoSystemR Controller
369611b 5 10.22.13
MUX
COM
MUX
QS
ECO 1 ECO 2
Test
Prueba
Tester
Ta > 65 ºC
LN
Patent: 7,391,297
500-15537 Rev. A
NEC®
Class 2
NEC
® Class 2
IEC PELV
0,5 N•m (5 in-lbs)
Ta ≤ 65 °C
www.lutron.com
u
Z096
65/75 ºC
Cu
Al
Power Module with EcoSystem
®
| Módulo de Potencia con EcoSystem
®
| Module d’Alimentation avec EcoSystem
®
LQSE-2ECO-D
243C IND.CONT.EQ.
8 mm
1.800.523.9466
+44.(0)20.7702.0657230 V~ 50/60 Hz 80 mA
120 V~ 50/60 Hz 120 mA
MUX
COM
MUX
QS
ECO 1 ECO 2
Test
Prueba
Tester
Ta > 65 ºC
LN
Patent: 7,391,297
500-15537 Rev. A
NEC®
Class 2
NEC
® Class 2
IEC PELV
0,5 N•m (5 in-lbs)
Ta ≤ 65 °C
www.lutron.com
u
Z096
65/75 ºC
Cu
Al
Power Module with EcoSystem® | Módulo de Potencia con EcoSystem® | Module d’Alimentation avec EcoSystem®
LQSE-2ECO-D
243C IND.CONT.EQ.
8 mm
1.800.523.9466
+44.(0)20.7702.0657230 V~ 50/60 Hz 80 mA
120 V~ 50/60 Hz 120 mA
Wiring: EcoSystem Loop®
Power Module with EcoSystemR will supply power
for two independent EcoSystemR Loops, which
support a maximum of 64 ballasts per loop.
Eco Wiring
• EcoSystemR Digital Loop can be wired as Mains
voltage or IEC PELV/NECR Class 2 for maximum
wiring flexibility.
• The Loop is polarity insensitive and can be wired in
any topology.
• Consult all national and local electrical codes for
separation requirements.
Wire Gauge
Maximum EcoSystem
®-
compliant Loop Wire Length
4.0 mm
2
(12AWG)
671 m (2200 ft)
2.5 mm
2
(14AWG)
427 m (1400 ft)
1.5 mm
2
(16AWG)
275 m (900 ft)
1.0 mm
2
(18AWG)
175 m (570 ft)
Eco 1
Eco 1
Eco 2
Eco 2
EcoSystem
®
Loop 1
EcoSystem®
Loop 2
EcoSystemR H-Series Ballast
EcoSystemR Digital Loop
EcoSystemR LED
Up to 64 EcoSystemR ballasts
or LED drivers
NEC is a registered trademark of the National Fire Protection Association, Quincy, Massachusetts
5
®
SPECIFICATION SUBMITTAL Page
Job Name:
Job Number:
Model Numbers:
Power Module with EcoSystemR LQSE-2ECO-D EcoSystemR Controller
369611b 6 10.22.13
Wiring: QS Link
IEC PELV/NECR Class 2 QS Link Wiring
• Link communicates using IEC PELV/NECR
Class 2 wiring.
• Follow all applicable national and local codes for
proper circuit separation and protection.
• Wiring may be daisy chained or t-tapped.
• Total length of QS link must not exceed 610m
(2000 ft).
• Do NOT connect terminal 2.
• Wire Gauge
- Power (terminals 1 and 2): 1 pair 1.0 mm( (18AWG)
- Data (terminals 3 and 4): 1 pair 0.5 mm( to 1.0mm(
(22AWG to 18AWG) twisted and shielded
- Can use LutronR cable GRX-CBL-346S-500
MUX
COM
MUX
QS
ECO 1 ECO 2
Test
Prueba
Tester
Ta > 65 ºC
LN
Patent: 7,391,297
500-15537 Rev. A
NEC®
Class 2
NEC
® Class 2
IEC PELV
0,5 N•m (5 in-lbs)
Ta ≤ 65 °C
www.lutron.com
u
Z096
65/75 ºC
Cu
Al
Power Module with EcoSystem
®
| Módulo de Potencia con EcoSystem
®
| Module d’Alimentation avec EcoSystem
®
LQSE-2ECO-D
243C IND.CONT.EQ.
8 mm
1.800.523.9466
+44.(0)20.7702.0657230 V~ 50/60 Hz 80 mA
120 V~ 50/60 Hz 120 mA
(1)
(2)
(3)
(4)
COM
No Connection
MUX
MUX
MUX
COM
MUX
QS
ECO 1 ECO 2
Test
Prueba
Tester
Ta > 65 ºC
LN
Patent: 7,391,297
500-15537 Rev. A
NEC®
Class 2
NEC
® Class 2
IEC PELV
0,5 N•m (5 in-lbs)
Ta ≤ 65 °C
www.lutron.com
u
Z096
65/75 ºC
Cu
Al
Power Module with EcoSystem® | Módulo de Potencia con EcoSystem® | Module d’Alimentation avec EcoSystem®
LQSE-2ECO-D
243C IND.CONT.EQ.
8 mm
1.800.523.9466
+44.(0)20.7702.0657230 V~ 50/60 Hz 80 mA
120 V~ 50/60 Hz 120 mA
NEC is a registered trademark of the National Fire Protection Association, Quincy, Massachusetts
6