Specifi cations
Standards
• UL Listed.
• FCC approved. Complies with the limits for a
Class B digital device, pursuant to Part 15 of the
FCC rules.
• cUL certifi ed, IC approved.
• NOM certifi ed, SCT approved in Q4 2010.
Power / Performance
• Operating voltage: 120 V~ 50/60 Hz
• Typical power consumption: 0.3 W (typical test
conditions = load off).
System Communication
• Communicates at 434 MHz through
Clear Connect
TM RF Technology for reliable
wireless communication.
Environment
• Ambient operating temperature:
32 – 104 ˚F (0 – 40 ˚C)
• Maximum 90% non-condensing relative humidity
• Indoor use only
Available Colors
• White (WH)
• Black (BL)
Load
• Maximum load: 15 A general purpose. No
minimum load requirements. *
• Motor rating: ½ HP
• Lutron’s patented Softswitch
® technology extends
the switch’s average life.
*
Some low wattage loads may try to start when the
Appliance Module is "OFF" due to a 0.5 mA leakage current
through the module in "OFF" state, similar to a night lighted
toggle switch. Consult the manufacturer of the load for
compatibility.
Key Design Features
• Green LED status indicator shows current load
status.
• Power failure memory: If power is interrupted,
when the power is restored the appliance module
will return to its previously set level prior to the
interruption.
Design Considerations
• When switching lamps with integral switches, the
integral switch must be left in the “on” position or
removed from the lamp. Always use a bulb that
remains within the manufacturer's wattage rating of
the table or fl oor lamp.
System Communication and Capacity
• Maestro Wireless RF appliance module
communicates with ceiling-mount occupancy
sensors and Pico
® wireless controls through radio
frequency (RF).
• Maestro Wireless local controls must be located
within 60 ft (18 m) line of sight or 30 ft (9 m) through
walls of a Radio Powr Savr
TM Sensor.
• Up to 10 Maestro Wireless controls can be
confi gured to work together.
Over-Temperature Detection
• If an over-temperature condition is detected, the
LED on the unit will fl ash a unique sequence
(double-blink, then pause) and turn the load
off. Proper installation and conformance to all
specifi cations should be ensured before proceeding.
To return the device to normal operation, simply
cycle power to the device.