Preset Dimming Controls
369310g 6 12.20.19
Job Name:
Job Number:
Model Numbers:
Page
SPECIFICATION SUBMITTAL
Control Unit with EcoSystem
Specifications
Infrared
• Infrared (IR) receiver allows infrared transmitters to select
8 scenes, raise/lower lighting zones,
or raise/lower shades.
• Transmitter buttons imitate buttons on faceplate.
• 50 ft (15 m) line of sight range.
• Terminal block infrared input for connection to a wired
IR input from third-party equipment.
• IR can be disabled via programming.
• Works with Lutron GRX-IT and GRX-8IT infrared
remote controls.
Accessory Controls: seeTouch QS Wallstations
(QSWS2)
• Wired seeTouch QS keypads provide the
following features:
– Access to one or more of the 16 scenes on the
GRAFIK Eye QS control unit
– Zone toggle, partitioning, sequencing, fine tune, panic
mode, and timeclock enable/disable
– Contact closure inputs
– Various other functions that are available on specific
wallstation configurations. Refer to the seeTouch
specification submittal.
Accessory Controls: QS Sensor Module (QSM2)
• The QS Sensor Module provides a means to link wired
or wireless occupancy sensors or daylight sensors, Pico
controls, and wired infrared sensors to a GRAFIK Eye QS
control unit via the wired QS link.
– Occupancy sensors wired (or wirelessly linked) to
a QS Sensor Module can be used by one or more
GRAFIK Eye QS control units on the wired link.
– Daylight sensors wired (or wirelessly linked) to a
QS Sensor Module can be used by one or more
GRAFIK Eye QS control units on the wired link.
– Infrared sensors can control either one or more zones or
scenes on the GRAFIK Eye QS control unit. Functionality
varies; refer to the documentation for the QS Sensor
Module for details.
– Pico wireless controls can control either one or more
zones or scenes on the GRAFIK Eye QS control unit.
– Pico wired controls can be used, when connected to
a QS Sensor Module, to control one or more zones or
scenes on the GRAFIK Eye QS control unit.
Accessory Controls: Contact Closure Input/Output
Interface (QSE-IO)
• Recalls preset light levels for the following set of scenes
on the GRAFIK Eye QS control unit:
Scenes 1-4 and Off Scenes 9-12 and Off
Scenes 5-8 and Off Scenes 13-16 and Off
• Sequence scenes 5-16, Enable/Disable Zone Lockout,
Enable/Disable Scene Lockout, Enable/Disable Panic
Mode, Enable/Disable Timeclock.
• Occupancy Sensors. An individual input counts as 1
occupancy sensor for the GRAFIK Eye QS control unit.
Each input can be assigned to either Scene Control or
Zone Control (please refer to the Occupancy Sensor(s)
section of this guide).
• Zone Toggle. Allows an input to toggle one or more zones
between programmable preset level(s) and off.
• Shade Output mode. A Shade Column on the
GRAFIK Eye QS control unit can be linked to control
outputs 1-3 and/or outputs 4-5 on the QSE-IO.
Accessory Controls:
DMX Output Interface (QSE-CI-DMX)
• Any zone on the GRAFIK Eye QS control unit can be
mapped to any single DMX512 Channel.
• Any zone on the GRAFIK Eye QS control unit can be
simultaneously mapped to any three DMX512 channels
(providing RGB/CMY control).
• DMX loads cannot be used with daylighting.
Accessory Controls: Ethernet and RS232 Interface
(QSE-CI-NWK-E)
• Allows for monitoring and control of the outputs and local
scenes of the GRAFIK Eye QS control unit.
Accessory Controls: QS Keyswitch Wallstations
(QSWS2-KS)
• Recalls preset light levels for any two scenes
including Off.
• Allows fine-tuning (raise/lower level) of a zone or
group of zones.
• Starts/Stops scene sequencing
(Scenes 1-4 or Scenes 5-16)
• Enables/Disables Timeclock
• Enables/Disables occupancy sensors
• Enables/Disabled daylight sensors
• Allows toggle of Zone(s) to a preset level and off.
• Enables/Disables panic mode.
• Starts/Stops afterhours mode.