Job Name:
Job Number:
Model Numbers:
PageSPECIFICATION SUBMITTAL
369787a 1 03.11.14
RF Local Controls5 A 2-Button RF Switch Designer-Style: Switch
5 A 2-Button RF Switch
The 5 A 2-Button RF Switch controls the load
automatically through wireless sensors and wireless
remote controls which provides a system that delivers
energy savings, convenience, and ease of installation.
The 5 A 2-Button RF Switch uses Lutron
R patented
Clear Connect
R RF Technology, which enables wireless
communication with Radio Powr SavrT sensors and
Pico
R wireless controls for total load control.
Features
The 5 A 2-Button RF Switch provides switching of
multiple load types, occupancy/vacancy sensing, and
daylight harvesting.
• Lutron
R patented Clear ConnectR RF Technology works
through walls and floors.
Includes Front Accessible Service Switch (FASST) for
safe lamp replacement.
Two-wire switch perfect for retrofit applications.
Power failure memory: If power is interrupted, the
control will return to its previously set level prior to
interruption.
Models:
Receiving Device
5 A 2-Button RF Switch
Transmitting Devices
Radio Powr SavrT Sensors
Ceiling-mounted
occupancy / vacancy
sensor
Wall-mounted
occupancy / vacancy
sensor
Daylight Sensor
1
No Neutral Required.
2
“XX” in the model number represents color/finish code.
3
To ensure proper installation install LUT-MLC.
Model Number Description Voltage Load Type Minimum Load Maximum Load
Not
Ganged
End of
Gang
Middle of
Gang
PD-5S-DV-XX
1,2
Electronic
Switch
120 / 277 V~ CFL / LED 40 W (LUT-MLC)
3
5 A 4 A 3 A
120 / 277 V~ Fluorescent 40 W (LUT-MLC)
3
5 A 4 A 3 A
120 V~
Incandescent /
Halogen
25 W 600 W 500 W 400 W
277 V~
Incandescent /
Halogen
25 W 1400 W 1100 W 800 W
120 V~ ELV 40 W (LUT-MLC)
3
600 W 500 W 400 W
277 V~ ELV 40 W (LUT-MLC)
3
1400 W 1100 W 800 W
120 V~ MLV 25 W
600 VA /
450 W
500 VA /
375 W
400 VA /
300 W
277 V~ MLV 25 W
1400 VA /
1000 W
1100 VA /
800 W
800 VA /
600 W
120 V~
General
Purpose Fan
0.4 A 3 A 3 A 3 A
PicoR Wireless
Control
1
Job Name:
Job Number:
Model Numbers:
PageSPECIFICATION SUBMITTAL
369787a 2 03.11.14
RF Local Controls5 A 2-Button RF Switch Designer-Style: Switch
Specifications
Regulatory Approvals
UL
R Listed
• CSA Certified
• FCC Approved. Complies with the limits for a Class B
digital device, pursuant to Part 15 of the FCC Rules
• Industry Canada Certified
Power
Operating voltage:
120 V~ 50/60 Hz
277 V~ 50/60 Hz
Key Design Features
All RF Local Controls
• Tested to withstand electrostatic discharge without
damage or memory loss, in accordance with
IEC 61000-4-2.
• Tested to withstand surge voltages without damage or
loss of operation, in accordance with
IEEE C62.41-1991 Recommended Practice on Surge
Voltages in Low-Voltage AC Power Circuits.
• Controls always operate locally and do not require
system control.
• Power failure memory: should power be interrupted,
the control will return to its previously set level prior to
the interruption when power is restored.
• Uses conventional 3-way wiring.
• Use LutronR Designer (ClaroR
and Satin ColorsR)
wallplates or designer-style wallplates from other
manufacturers. Wallplates are sold separately.
• Lutron ClaroR and Satin ColorsR wallplates snap on
with no visible means of attachment.
• Requires a 1-gang U.S. wallbox. 3
1
2 in (89 mm) deep
recommended, 2
1
4 in (57 mm) deep minimum.
• Green status LED.
System Communications and Capacity
• The 5 A 2-Button RF Switch communicates with
the Pico
R wireless controls and Radio Power
SavrT sensors through radio frequency (RF).
• The 5 A 2-Button RF Switch must be located
within 60 ft (18 m) line of sight or 30 ft (9 m)
through walls, of Radio Power SavrT sensors.
• The 5 A 2-Button RF Switch must be located
within 60 ft (18 m) line of sight or 30 ft (9 m)
through walls, of a Pico
R wireless control.
Environment
• Ambient operating temperature: 32 °F to 104 °F
(0 °C to 40 °C), 0%-90% humidity,
non-condensing. Indoor use only.
2
Job Name:
Job Number:
Model Numbers:
PageSPECIFICATION SUBMITTAL
369787a 3 03.11.14
RF Local Controls5 A 2-Button RF Switch Designer-Style: Switch
Mounting
Wallbox
Control
Adapter
Mounting
Screws
Control
Mounting
Screws
Wallplate / Adapter
purchased separately.
Operation
IMPORTANT NOTICE:
FASST - Front Accessible Service Switch - to service load, remove power by pulling the FASST switch out
completely on Switch. After servicing load, push the FASST switch back in fully to restore power to the control.
On
FASST
Front
Accessible
Service
Switch
Switch
Status LED
Indicates load status; glows softly as
night light when light is off
Off
3
Job Name:
Job Number:
Model Numbers:
PageSPECIFICATION SUBMITTAL
369787a 4 03.11.14
RF Local Controls5 A 2-Button RF Switch Designer-Style: Switch
Dimensions
Front View
Side View
5/16 in
(8 mm)
1
1
8 in
(30 mm)
4
11
16 in
(119 mm)
2
15
16 in
(75 mm)
When ganging with other controls in the same wallbox,
derating is required. See Load Type and Capacity chart.
Do Not remove outside fins on
end of gang controls
Middle of gang
control has all fins
removed
Ganging and Derating
Each control has
inside fins removed
Load Type Minimum
Load
Maximum Load
Not
Ganged
End of
Gang
Middle
of Gang
CFL / LED
40 W
(LUT-MLC)
1
5 A 4 A 3 A
Fluorescent
40 W
(LUT-MLC)
1
5 A 4 A 3 A
Incandescent /
Halogen (120 V~)
25 W 600 W 500 W 400 W
Incandescent /
Halogen (277 V~)
25 W 1400 W 1100 W 800 W
ELV (120 V~)
40 W
(LUT-MLC)
1
600 W 500 W 400 W
ELV (277 V~)
40 W
(LUT-MLC)
1
1400 W 1100 W 800 W
MLV (120 V~) 25 W
600 VA /
450 W
500 VA /
375 W
400 VA /
300 W
MLV (277 V~) 25 W
1400 VA /
1000 W
1100 VA /
800 W
800 VA /
600 W
General Purpose
Fan
0.4 A 3 A 3 A 3 A
Load Type and Capacity
1
To ensure proper installation install LUT-MLC.
4
Job Name:
Job Number:
Model Numbers:
PageSPECIFICATION SUBMITTAL
369787a 5 03.11.14
RF Local Controls5 A 2-Button RF Switch Designer-Style: Switch
Single Location Installation
Brass
Black
Blue - unused, tighten
1
Green
Ground
Line / Hot
Neutral
5 A 2-Button RF Switch
Wiring Diagrams
3-Way Installation
With Mechanical Switch
Black
Black
Green
Ground
Ground
Brass
Black
Black
No
connection
Green
Ground
Line / Hot
Line / Hot
Neutral
Neutral
Mechanical Switch
2
PicoR
wireless
control
and
wallbox
mounting
adapter
PicoR
wireless
control
and
wallbox
mounting
adapter
Load
Load
Load
120 V~
50 / 60 Hz
or
277 V
~
50 / 60 Hz
120 V~
50 / 60 Hz
or
277 V
~
50 / 60 Hz
120 V~
50 / 60 Hz
or
277 V
~
50 / 60 Hz
LUT-MLC*
1
When using controls without mechanical 3-way switch, cap blue terminal. DO NOT connect the blue wire to any other wiring or to ground.
2
Location of RF switch and mechanical switch may be reversed.
*
A LUT-MLC ensures proper function when fluorescent, CFL, or LED
loads are used. Install the LUT-MLC inside a load fixture or in a
separate J-box of the circuit. May also be installed in J box with
switch if neutral is present and space permits.
LUT-MLC*
LUT-MLC*
5 A 2-Button RF Switch
2
5 A
2-Button
R
F
Switch
2
Black
Blue
Black
Multi-location Installation
With PicoR wireless controls (PJ2-2B-xx) and wallbox mounting adapters (PICO-WBX-ADAPT)
Blue - unused, tighten
1
5
Job Name:
Job Number:
Model Numbers:
PageSPECIFICATION SUBMITTAL
369787a 6 03.11.14
RF Local Controls5 A 2-Button RF Switch Designer-Style: Switch
Colors and Finishes
Gloss Finishes
Due to printing limitations, colors and finishes shown cannot be guaranteed to perfectly match actual
product colors.
White
WH
Black
BL
Ivory
IV
Light Almond
LA
6