SPECIFICATION SUBMITTAL Page
Job Name:
Job Number:
Model Numbers:
Wallstations
369715b 1 08.31.15
®
ArchitraveT QS Keypads
QSWA-KP5-DW-___
5 Button Wallstation with
Raise/Lower
Description
Used to control one or more lighting or
shades / draperies groups simultaneously.
Receives up to two contact closure inputs
via a connector on the back of the Wallstation.
The LEDs next to each button are used during
programming and provide feedback when the
buttons are pressed.
Only available with green LEDs.
QSWA-KP5-DW-WH
LED
Color / Finish
Note: Wallbox may not be required
for all installations. Consult
local electrical codes for
Class 2 devices.
3.8125 in
(97 mm)
4.375 in
(112 mm)
1.25 in
(32 mm)
ArchitraveT Wallbox
P/N 241399
(Sold separately)
2.75 in
(70 mm)
1
®
SPECIFICATION SUBMITTAL Page
Job Name:
Job Number:
Model Numbers:
Wallstations
369715b 2 08.31.15
®
ArchitraveT QS Keypads
QSWA-KP5-DN-___
5 Button Wallstation with
Raise/Lower
Description
Used to control one or more lighting or
shades / draperies groups simultaneously.
Receives up to two contact closure inputs
via a connector on the back of the Wallstation.
The LEDs next to each button are used during
programming and provide feedback when the
buttons are pressed.
Only available with green LEDs.
QSWA-KP5-DN-WH
LED
Color / Finish
Note: Wallbox may not be required
for all installations. Consult
local electrical codes for
Class 2 devices.
3.8125 in
(97 mm)
4.375 in
(112 mm)
1.250 in
(32 mm)
ArchitraveT Wallbox
P/N 241399
(Sold separately)
2.75 in
(70 mm)
2
®
SPECIFICATION SUBMITTAL Page
Job Name:
Job Number:
Model Numbers:
Wallstations
369715b 3 08.31.15
®
ArchitraveT QS Keypads
QSWA-KP7-DW-___
7 Button Wallstation
Description
Used to control one or more lighting or
shades / draperies groups simultaneously.
Receives up to two contact closure inputs
via a connector on the back of the Wallstation.
The LEDs next to each button are used during
programming and provide feedback when the
buttons are pressed.
Only available with green LEDs.
QSWA-KP7-DW-WH
LED
Color / Finish
Note: Wallbox may not be required
for all installations. Consult
local electrical codes for
Class 2 devices.
3.8125 in
(97 mm)
4.375 in
(112 mm)
1.250 in
(32 mm)
ArchitraveT Wallbox
P/N 241399
(Sold separately)
2.75 in
(70 mm)
3
®
SPECIFICATION SUBMITTAL Page
Job Name:
Job Number:
Model Numbers:
Wallstations
369715b 4 08.31.15
®
ArchitraveT QS Keypads
QSWA-KP7-DN-___
7 Button Wallstation
Description
Used to control one or more lighting or
shades / draperies groups simultaneously.
Receives up to two contact closure inputs
via a connector on the back of the Wallstation.
The LEDs next to each button are used during
programming and provide feedback when the
buttons are pressed.
Only available with green LEDs.
QSWA-KP7-DN-WH
LED
Color / Finish
Note: Wallbox may not be required
for all installations. Consult
local electrical codes for
Class 2 devices.
3.8125 in
(97 mm)
4.375 in
(112 mm)
1.250 in
(32 mm)
ArchitraveT Wallbox
P/N 241399
(Sold separately)
2.75 in
(70 mm)
4
®
SPECIFICATION SUBMITTAL Page
Job Name:
Job Number:
Model Numbers:
Wallstations
369715b 5 08.31.15
®
ArchitraveT QS Keypads
Specifications for QSWA ArchitraveT Keypads
Power Input (Control Link Terminal 2)
SELV / PELV / NECR Class 2. Operating voltage: 2436 V 30 mA
Key Design Features
Meets IEC 801-2. Tested to withstand 15 kV electrostatic discharge
without damage or memory loss.
Faceplate snaps on with no visible means of attachment.
Use Faceplate Replacement Kits to change faceplate color.
System Communications and Capacity
SELV / PELV / NECR Class 2 wiring connects Wallstations to other devices on
the QS Link.
A QS system can have up to 100 devices and 100 zones; ArchitraveT QS
wallstations each count as 1 device and 0 zones on the QS Link.
An ArchitraveT QS wallstation consumes 1 power draw unit (PDU) on the
QS link. For complete information, see “Power Draw Units on the QS Link,
LutronR PN 369405.
Terminals
Accept up to two 18 AWG (1.0 mm
2
).
Environment
32 °F to 104 °F (0 °C to 40 °C). Relative humidity less than 90% non-condensing.
Compatibility
ArchitraveT QS keypads are compatible with GRAFIK EyeR QS control units,
SivoiaR
QS Shades / Draperies, Energi Savr NodeT units, and QuantumR
system devices.
Mounting
Backbox dimensions:
4.375 in (112 mm) high, 1.25 in (32 mm) wide, 2.75 in (70 mm) deep.
Dimensions
Front View
Back View
QS Link
Connector
Sensor/
Contact
Closure
Input
Connector
Keypad
3.8125 in
(97 mm)
4.375 in
(112 mm)
1.25 in
(32 mm)
ArchitraveT Wallbox
P/N 241399
(Sold separately)
2.75 in
(70 mm)
Keypad
Mounting
Screws
Faceplate
Door Wide
QSWA-KP5-DW
Door Narrow
QSWA-KP5-DN
4.5 in
(114 mm)
1.8125 in
(46 mm)
1.3125 in
(34 mm)
Side View
0.1875 in
(5 mm)
1.4375 in
(37 mm)
5
®
SPECIFICATION SUBMITTAL Page
Job Name:
Job Number:
Model Numbers:
Wallstations
369715b 6 08.31.15
®
ArchitraveT QS Keypads
Available Control Types
ArchitraveT QS wallstations are available as Lights Only:
Lights Only Lights Only
Lights Only
Controls only lights.
Has a programmable column type (choose from the list on the following pages).
KP5 models default to 5 scenes with Raise / Lower.
KP7 models default to 7 scenes.
Note:
Column types can be changed using the GRAFIK EyeR QS control unit programming menu and the ESN HHD
application (e.g., control that is programmed as "Lights Only" can be changed to "Shades / Draperies Only").
QSWA-KP5-DW-WH
QSWA-KP7-DW-WH
6
®
SPECIFICATION SUBMITTAL Page
Job Name:
Job Number:
Model Numbers:
Wallstations
369715b 7 08.31.15
®
ArchitraveT QS Keypads
Available Column Types
Scene (with Off)
Controls preprogrammed scenes on one or more scene controllers (such as a GRAFIK EyeR QS control unit,
or an area on an Energi Savr NodeT unit).
Buttons within a column control the same scene controller(s) (different buttons within a column cannot control
different scene controllers).
The scene recalled by the first button in a column is programmable, subsequent buttons recall the next numerical
scene, and the last button always recalls Scene Off.
A 1 button scene Wallstation will always toggle between the assigned scene and Scene Off.
Scene (without OFF)
Identical function to Scene with Off, except the last button in a column recalls the next consecutive scene, not
Scene Off.
Zone Toggle
Buttons toggle a zone or group of zones between programmable preset values and Off (where all zones are Off).
Each zone can be programmed to a different value.
Each button can be individually programmed to a different zone or group of zones.
Partition
Allows the user to assign individual buttons of a column to different scene controllers (areas).
A single button press on the wallstation indicates an open partition (LED ON) within the space. Devices
programmed to that button communicate with each other in both directions.
A second button press on the wallstation indicates a closed partition (LED OFF) within the space so that devices
programmed to that button function independently.
2B Partition (2 button Wallstation only)
Identical function to Partition, except that there are two buttons.
A top button press indicates an open partition; a bottom button press indicates a closed partition.
2B Fine Tune (2 button Wallstation only)
Buttons function as raise and lower buttons for assigned zones.
A button tap will raise/lower the level of assigned zones by 1%.
Press and holding the buttons smoothly raises to high end or smoothly lowers to low end.
2B Sequence (2 button Wallstation only)
All assigned scene controllers continuously cycle through either Scenes 1-4 or Scenes 5-16 using the
programmed fade times for each scene.
Useful for spaces that desire dynamic lighting, such as decorative lighting or displays in retail stores.
A top button press starts sequencing; a bottom button press stops sequencing.
(continued on next page)
7
®
SPECIFICATION SUBMITTAL Page
Job Name:
Job Number:
Model Numbers:
Wallstations
369715b 8 08.31.15
®
ArchitraveT QS Keypads
Available Column Types (continued)
2B Panic (2 button Wallstation only)
Button press causes all assigned scene controllers go to Scene 16.
Temporarily disables all button presses and ignores scene or zone level changes.
A top button press enables Panic Mode; a bottom button press disables Panic Mode.
2B Timeclock (2 button Wallstation only)
Allows the user to enable or disable the timeclock on a GRAFIK EyeR QS control unit.
A top button press enables the timeclock; a bottom button press disables the timeclock.
Shades / Draperies
Wallstation must have more than 1 button.
Raise/Lower buttons are recommended for programming.
The top button becomes the Open button; the bottom button becomes the Close button for associated LutronR
SivoiaR
QS shades / draperies or third-party AC window treatments.
For keypads with more than two buttons, the middle buttons are programmable Preset buttons.
Shades / Draperies Group
Available only on a multi-column keypad where another column is a shades / draperies column.
Allows the shades / draperies column to operate as multiple independent keypads (one per group).
Group / button with LED ON indicates which shades / draperies group is currently active.
Note:
Column types can be changed using the GRAFIK EyeR QS control unit programming menu and the ESN HHD
application (e.g., control that is programmed as "Lights Only" can be changed to "Shades / Draperies Only").
Additional programming features are available in a QuantumR system application.
8
®
SPECIFICATION SUBMITTAL Page
Job Name:
Job Number:
Model Numbers:
Wallstations
369715b 9 08.31.15
®
ArchitraveT QS Keypads
Color/Finish Codes
Architectural Matte Finishes (Metal)
With White plastic buttons (standard).
White WH
Architectural Metal Finishes
With black plastic buttons (standard).
Bright Brass BB
Bright Chrome BC
Bright Nickel BN
Satin Brass SB
Satin Chrome SC
Satin Nickel SN
Antique Brass QB
Antique Bronze QZ
Gold AU
Anodized Aluminum Finishes
With black plastic buttons (standard).
Clear CLA
Black BLA
Brass BRA
Notes:
Color chip keychains are available for
more precise color matching:
Architectural Matte Finishes
- AM- CK-1
Architectural Metal Finishes
- AMTL-CK-1
Buttons for QS Architrave are not field
replaceable
If no color is specified, wallstations will
ship with White (WH) finish (Metal)
QSWA- - -
Prefix
Color/
Finish
Button
Configuration
(see below)
Faceplate
Style
DW: Door Wide
DN: Door Narrow
Engraving Note
For Custom Faceplate Engraving,
contact Lutron Customer service at:
1.888.LUTRON1
Button Configurations
KP5
7 Button;
w/5 LEDs
KP7
7 Button;
w/7 LEDs
How to Build an Standard ArchitraveT QS Model Number
9
®
SPECIFICATION SUBMITTAL Page
Job Name:
Job Number:
Model Numbers:
Wallstations
369715b 10 08.31.15
®
ArchitraveT QS Keypads
ArchitraveT Replacement Faceplate Information
Use Replacement Faceplates to change the colors of faceplates.
Faceplate
Replacement Faceplates
AR-M4-DW-XX**-E
7 Button w/5 LEDs, Door Wide
AR-M4-DN-XX**-E
7 Button w/5 LEDs, Door Narrow
AR-M16-DW-XX**-E
7 Button w/7 LEDs, Door Wide
AR-M16-DN-XX**-E
7 Button w/7 LEDs, Door Narrow
Notes:
Contact Lutron Customer Service for Multigang
Installations: 1.888.LUTRON1
• ArchitraveT buttons are not field replaceable
10
®
SPECIFICATION SUBMITTAL Page
Job Name:
Job Number:
Model Numbers:
Wallstations
369715b 11 08.31.15
®
ArchitraveT QS Keypads
Wallstation Wiring
QS Link Wiring
Use SELV / PELV / NECR Class 2 wiring to connect
Wallstations to the QS link.
Connect two 22 AWG (0.5 mm
2
) shielded, twisted
pair wires to terminals 3 and 4 of the wallstations
control link connector. Shielding (drain) of the
twisted pair wires must be connected together as
shown, but do not connect the shielding to earth/
ground or the wallstation and do not allow it to
contact the grounded wallbox.
Connect the appropriate size wires to terminals 1
and 2 for power, according to your link length (see
table below).
Connect Drain/Shield as shown. Do not connect to
Ground (Earth) or Wallstation. Connect the bare
drain wires and cut off the outside shield.
Note: Use appropriate wire connecting devices as
specified by local codes.
(2) 18 AWG 1.0 mm
2
)
(2) 18 AWG (1.0 mm
2
)
Data Link:
(1) Twisted, shielded pair
22 AWG (0.5 mm
2
)
3: MUX
4: MUX
Back View
D: Drain/Shield
QS Link Wire Sizes (check compatibility in your area)
QS Link Wiring Length Wire Gauge Lutron Cable Part Number
Less than 500 ft (153 m)
Power (terminals 1 and 2)
1 pair 18 AWG (1.0 mm
2
) GRX-CBL-346S (non-plenum)
GRX-PCBL-346S (plenum)
Data (terminals 3 and 4)
1 twisted, shielded pair 22 AWG (0.5 mm
2
)
500 ft to 2000 ft
(153 m to 610 m)
Power (terminals 1 and 2)
1 pair 12 AWG (4.0 mm
2
) GRX-CBL-46L (non-plenum)
GRX-PCBL-46L (plenum)
Data (terminals 3 and 4)
1 twisted, shielded pair 22 AWG (0.5 mm
2
)
Link Wiring less than 500 ft (153 m)
SELV / PELV / NEC® Class 2 Control Wiring:
(2) 18 AWG (1.0 mm
2
)
1: Common
2: V+
1
2
3
4
A
B
C
(2) 12 AWG (4.0 mm
2
)
Link Wiring 500 ft (153 m) to 2000 ft (610 m)
Data Link:
(1) Twisted, shielded pair
22 AWG (0.5 mm
2
)
3: MUX
4: MUX
D: Drain/Shield
1
2
3
4
SELV / PELV / NEC® Class 2
Control Wiring:
(2) 18 AWG (1.0 mm
2
)
1: Common
2: V+
(2) 12 AWG (4.0 mm
2
)
11
®
SPECIFICATION SUBMITTAL Page
Job Name:
Job Number:
Model Numbers:
Wallstations
369715b 12 08.31.15
®
ArchitraveT QS Keypads
Wallstation Wiring (continued)
Contact Closure Inputs
Specifications
Inputs must be dry contact closure, solid-state,
open collector (NPN/PNP), or active-low (NPN)/
active-high (PNP) output.
- Open collector (NPN) or active-low (NPN) on-state
voltage must be less than 2 V and sink 3.0 mA
- Open collector (PNP) or active-high (PNP) on-state
voltage must be greater than 12 V and source
3.0 mA
Wallstation is miswire protected up to 36 V .
Outputs must stay in the closed or open states
for at least 40 ms in order to be recognized by the
Wallstation.
Contact Closure Input Wiring
Use low-voltage SELV / PELV / NEC® Class 2 wiring to
connect the contact closure inputs to the Wallstation.
B: Input 2
C: Common
A: Input 1
(3) 18 AWG
(1.0 mm
2
)
Back View
1
2
3
4
A
B
C
12