PROLAM LAMINATED H3.2 POSTS
PURPOSE
Prolam glue laminated H3.2 posts are supplied as a grade PL8 structural member.
The post can be supported on a structural bracket above ground.
EXPLANATION
Prolam H3.2 posts are manufactured from N.Z. grown Pinus Radiata. The laminates are
glued with resorcinol adhesive.
Prolam H3.2 posts are supplied in:
>
a range of sizes
>
structural grade PL8
>
appearance grades A & C
>
treatment hazard class H3.2 (CCA)
Prolam lamina are individually treated prior to lamination and finishing. This is to
ensure each lamina achieves the same penetration and retention as solid lumber
treated under NZS 3640:2003.
The manufacture of Prolam H3.2 posts are third-party certified by AsureQuality to
AS/NZS 1328 part 2 or AS 1720.1:2010 (but branded with the prefix PL). Prowood NZ is
registered by the Timber Preservation Association of Australia in respect of the CCA
treatment protocol.
SCOPE AND LIMITATIONS OF USE
For further assistance
please contact:
03 526 7436
info@prowoodnz.com
www.prolamnz.com
Scope
Limitations
Building
In accordance with NZS3604:2011 or specifically engineered
to NZS 3603:1993 and AS/NZS 1170:2002.
USEFUL
INFORMATION
For information on the design, installation and maintenance
of Prolam H3.2 posts and for our warranty refer to
www.prolamnz.com.
OTHER CERTIFICATIONS AND APPROVALS
HELD BY PROWOOD NZ
The following certifications and approvals are held by
Prowood Ltd.
>
AsureQuality Engineered Wood Products Programme (AEWP)
Reg no: AEWP05/Certificate No: 03, 3/7/2017.
>
Certificate of Registration of Preservative Treatment &
Allocated Brand, 709 01 H3.2, 708 90 H3.2.
>
Prolam H3.2 posts must not be ripped where this would result in
a reduction in the number of lamina; dimensional stability and
strength relies on the width and thickness remaining unchanged
>
Fixing material to be in accordance with section 4,
NZS 3604:2011.
>
Where NZ Building Code Clause C3 applies, the use of Prolam
H3.2 posts is subject to specific design by a fire engineer
VERSION:
SOURCES OF INFORMATION
>
AS/NZS 1328:1998 (parts 1, 2) Glued laminated structural timber
>
NZS 3603:1993 Timber structures
>
NZS 3604:2011 Timber-framed buildings
>
NZS 3640:2003 Chemical preservation of round and sawn timber
>
AS/NZS 1604.5:2012 Specification for preservative treatment
Part 5; Glue laminated timber products
igned by
odman
9.08.07
+12'00'
onfirms that, in
the company has met
ding Act 2004.
This Product Assurance Supplier Statement (pass™) has been prepared by TBB in accordance with MBIE PTS guidelines and the recommendations of s9.2,
Determination No. 2019-011 (issued 12 April 2019). TBB is ISO9001:2016 certified. Copyright © 2017, The Building Business Limited (TBB). All rights reserved.
PERFORMANCE CLAIMS
If designed, installed and maintained in accordance with all Prowood Ltd requirements, the Prolam H3.2 posts will comply with or
contribute to compliance with the following performance claims:
B1 Structure
B1.3.1
B1.3.2
B1.3.3 (a, b, f, j, m, q)
B1.3.4 (a, b, c, d, e)
B2 Durability
B2.3.1(a) B2.3.2(a)
C Protection from Fire
C6.3
C6.4
F2 Hazardous
Building Materials
F2.3.1
ACCEPTABLE SOLUTION
B1/AS1:
NZS 3604:2011, clause 2.3.9.3.
AS/NZS 1170.2002 (set)
VERIFICATION METHOD
B2/VM1: Clause 1.3 Verification
through comparison with similar
material.
ALTERNATIVE SOLUTION
NZS 3603:2011, clause 9.4.2.
ALTERNATIVE SOLUTION.
NZTPC Best Practice Guideline for the
Safe Use of Timber Preservatives &
Anti-sapstain Chemicals. Establishes
drying & flash off requirements.
>
NZS 3604:2011, clause. 2.3.9.3 requires glue laminated timber to
be manufactured in accordance with AS/NZS 1328 (Parts 1, 2)
>
Prowood Ltd third party certified, AsureQuality Engineered
Wood Products Programme: AS/NZS 1328:1998 (Parts 1, 2)
>
AsureQuality is JAS-ANZ accredited
>
AS/NZS1604.5, clause 1.9 requires the same characteristic
values for penetration and retention as defined in
NZS 3640:2003
>
Registered by Timber Preservers Association of Australia (CCA)
>
Subject to Prowood treatment protocol to
AS/NZS 1604.5:2012 and NZS 3640:2003
>
NZS 3603:1993, clause 9.4.2 specifies charring rate of radiata
pine and other timber species of approximately the same
density to be taken as 0.65 mm/min
>
APA Evaluation of Char Rate (ASTM E119), TT-118 January 2015
>
Glue laminated timber elements have a fire performance
comparable to solid wood members of equivalent size;
Timber Industry Federation New Zealand Timber Design
Guide 2007
>
Subject to Prowood treatment protocol and Prowood health
and safety plan
>
TBB audited manufacturing/treatment process
1. The Compliance Statement is the pass holder’s statement that they have met their obligations under s14G(2) of the Building Act 2004.
VERSION:
DATE:
Signed on behalf of Prowood Ltd:
Note: Uncontrolled in printed format.
John
Digitally s
John Wo
NAME:
Woodman
Date: 201
14:59:18
By signing this pass™ the signatory c
POSITION:
respect of the subject of this pass™,
their s14G obligations under the Buil
283 Waiwhero Road, Motueka
info@prowoodnz.com
03 526 7436
www.prolamnz.com
BASIS OF COMPLIANCE
1
Compliance statement
Demonstrated by
N.Z. Building
Code clauses
PROLAM H5 POSTS
PURPOSE
Prolam H5 posts are glue laminated structural posts treated to H5. They can be supported
on a structural bracket above ground or cast below ground, in a concrete foundation.
EXPLANATION
Prolam H5 posts are manufactured using NZ grown Pinus Radiata. They are third party
certified by AsureQuality to AS/NZS 1328 part 2 or AS 1720.1:2010, but branded with the
prefix PL.
They are supplied in:
>
a range of sizes
>
structural grade PL8, PL17
>
appearance grades A & C
>
treated to hazard class H5 (CCA).
Prolam lamina are individually treated and this ensures each lamina meets the
penetration and retention requirements in accordance with NZS 3640:2003. Following
treatment, the laminates are dried and glued with resorcinol adhesive and then
finished to final dimensions.
Given the size of the individual lamina, this has the effect of achieving
a penetration greater than solid lumber where the solid lumber’s
dimensions exceed 60 mm in thickness as per the following diagram.
It demonstrates that the lamination/finishing will have no effect on the
penetration or retention achieved.
Where used in-ground, the post must be fully encased in concrete
to ground level. This ensures that the structural performance and
durability of a post is maintained.
When used in accordance with Prolam’s installation, care and maintenance
instructions, the Prolam H5 posts will not warp, twist or delaminate.
Prowood NZ is registered by the Timber Preservation Association of
Australia in respect of the CCA treatment protocol.
SCOPE AND LIMITATIONS OF USE
For further assistance
please contact:
03 526 7436
info@prowoodnz.com
www.prolamnz.com
Scope
Limitations
Building
In accordance with NZS 3604:2011 or
specifically engineered to NZS 3603:1993
and AS 1720.1:2010.
>
Prolam H5 posts must not be ripped where this would result in a reduction in the
number of lamina; dimensional stability and strength relies on the width and thickness
remaining unchanged.
>
Fixing material to be in accordance with section 4, NZS 3604:2011.
>
Where NZ Building Code clause C3 applies, the use of Prolam H5 posts is subject to
specific design by a fire engineer.
Above and below-ground applications.
USEFUL INFORMATION
For information on the design, installatio
>
Above ground the post must be attached to a structural bracket that will resist all
applied loads.
>
Where installed below ground, the post must be:
seated on a punch pad of a 100 mm, and
fully encased in concrete with a minimum 75 mm side cover.
n and maintenance of Prolam H5 posts and for our warranty, refer to www.prolamnz.com.
VERSION:
Figure 1: Required penetration as required by NZS3640, dark grey shows penetration.
125
100
125
Senton Piles
Prolam H5 Post
180
180
40
30
30
30
30
igned by
odman
9.08.07
+12'00'
onfirms that, in
the company has met
ding Act 2004.
This Product Assurance Supplier Statement (pass™) has been prepared by TBB in accordance with MBIE PTS guidelines and the recommendations of s9.2,
Determination No. 2019-011 (issued 12 April 2019). TBB is ISO9001:2016 certified. Copyright © 2017, The Building Business Limited (TBB). All rights reserved.
PERFORMANCE CLAIMS
If designed, installed and maintained in accordance with all Prowood Ltd requirements, the Prolam H5 posts will comply with or
contribute to compliance with the following performance claims.
N.Z. Building
Code clauses
BASIS OF COMPLIANCE
1
Compliance statement
Demonstrated by
B1 Structure
B1.3.1
B1.3.2
B1.3.3 (a, b, f, j, m, q)
B1.3.4 (a, b, c, d, e)
ACCEPTABLE SOLUTION
B1/AS1
NZS 3604:2011, clause 2.3.9.3
AS 1720.1:2010
NZS 3603:1993
>
NZS 3604:2011, clause. 2.3.9.3 requires glue laminated
timber to be manufactured in accordance with
AS/NZS 1328 (parts 1, 2).
>
Prowood Ltd third party certified, AsureQuality Engineered
Wood Products Programme: AS/NZS 1328:1998 (parts 1, 2).
>
AsureQuality is JAS-ANZ accredited.
B2 Durability
B2.3.1(a) B2.3.2(a)
ACCEPTABLE SOLUTION
B2/AS1
>
Treated in accordance with NZS 3640:2003 to achieve the
same or greater treatment penetration than solid timber.
>
Registered by Timber Preservers Association of Australia (CCA).
C6 Structural Stability
C6.3
C6.4
ALTERNATIVE SOLUTION
NZS 3603:2011, clause 9.4.2
>
NZS 3603:1993, clause 9.4.2 specifies charring rate of radiata
pine and other timber species of approximately the same
density to be taken as 0.65 mm/min.
>
APA Evaluation of Char Rate (ASTM E119), TT-118 January 2015.
>
Glue laminated timber elements have a fire performance
comparable to solid wood members of equivalent size;
Timber Industry Federation New Zealand Timber Design
Guide 2007.
F2 Hazardous
Building Materials
F2.3.1
ALTERNATIVE SOLUTION
>
Subject to Prowood treatment protocol and Prowood health
and safety plan.
>
TBB audited manufacturing/treatment process.
1. The Compliance Statement is the pass holder’s statement that they have met their obligations under s14G(2) of the Building Act 2004.
SOURCES
OF INFORMATION
>
AS/NZS 1328:1998 (parts 1, 2) Glued laminated
structural timber.
>
AS 1720.1: 2010 Timber Structure Design Methods.
>
NZS 3603:1993 Timber structures.
>
NZS 3604:2011 Timber-framed buildings.
>
NZS 3640:2003 Chemical preservation of round
and sawn timber.
OTHER CERTIFICATIONS
AND APPROVALS HELD
BY PROWOOD LTD
>
AsureQuality Engineered Wood Products Programme
(AEWP) Reg no: AEWP05/Certificate No: 03, 3/7/2017.
>
Certificate of Registration of Preservative Treatment &
Allocated Brand 709 90 H5, 709 01 H5, 708 89 H5, 1/7/18.
VERSION:
DATE:
Signed on behalf of Prowood Ltd:
Note: Uncontrolled in printed format.
John
Digitally s
John Wo
NAME:
Woodman
Date: 201
15:00:56
By signing this pass™ the signatory c
POSITION:
respect of the subject of this pass™,
their s14G obligations under the Buil
283 Waiwhero Road, Motueka
info@prowoodnz.com
03 526 7436
www.prolamnz.com
USEFUL
INFORMATION
For information on the design, installation and
maintenance of Prolam beams, and for our warranty,
refer to www.prolamnz.com.
OTHER CERTIFICATIONS HELD
BY PROWOOD LTD
The following certications and approvals are held by
Prowood Ltd.
Certicate of Registration of Preservative Treatment &
Allocated Brand (Timber Treatment Plant Registration
Authority;
709 11 H1.2, 614 11 H1.2,
709 01 H3.2, 709 90 H3.2.
AsureQuality Engineered Wood Products Programme
Reg: AEWPO5/03 exp 3/7/2020
PROLAM BEAMS
PURPOSE
Prowood Ltd supplies Prolam laminated H1.2 and H3.2 treated beams (Prolam
Beams) for use as structural members in buildings.
PROLAM BEAMS EXPLAINED
Prolam Beams are glue laminated, branded with the prex PL and manufactured
from NZ grown Pinus Radiata and Douglas Fir.
The manufacturing of Prolam Beams is third-party certied by AsureQuality.
Structural performance is to AS/NZS 1328 part 2 or AS 1720.1:2010.
They are available in visual and non-visual grades.
Prolam beams are supplied in a range of; sizes; structural grades PL8, PL12 and
PL17; appearance grades visual and non-visual; and treatment levels H1.2 (boron)
and H3.2 (CCA).
pass™ no:
Expires:
For further assistance
please contact:
03 526 7436
info@prowoodnz.com
www.prolamnz.com
SCOPE AND LIMITATIONS OF USE
Scope Limitations
Building
As a direct substitute to SG8 and SG12 (or other equivalent)
as referenced in Section 8 NZS 3604:2011; or specically
engineered to NZS 3603:1993 or AS/NZS 1170:2002 (set).
Prolam beams must not be ripped where this would result in
a reduction of width or thickness. Structural performance on
the width and thickness remaining unchanged.
Fixing material to be in accordance with section 4, NZS
3604:2011.
In applications appropriate to the hazard class to which the
supplied Prolam beams are treated.
Prolam beams must be separated from exposed uncured
concrete and concrete that continues to be exposed to
moisture.
In applications where NZ Building Code Clause C3 obligations
for Fire aecting areas beyond the source apply.
The use of Prolam beams is subject to specic design by
a re engineer.
VERSION:
19013
06/2020
v1.0
PERFORMANCE CLAIMS
If designed, installed and maintained in accordance with all of Prowood Ltd requirements, Prolam beams will comply with or
contribute to compliance with the following performance claims..
SOURCES OF INFORMATION
The following information was relied upon to prepare this pass.
ICC-ES and APA Joint Evaluation Report ESR-1225 Pacic
Woodtech Corporation PWI Joists 10/17.
IVS Timber Testing Report 39361 19/11/18.
IVS Labs Analysis Report R32568 Boron Preservative in
Timber 5/12/18.
NZS 3603:1993 Timber structures.
NZS 3604:2011 Timber-framed buildings.
NZS 3640:2003 Chemical preservation of round
and sawn timber.
AS/NZS 1604.5:2012 Specication for preservative treatment:
Glued laminated timber products.
NZ Building
Code clauses
BASIS OF COMPLIANCE
Compliance statement
1
Demonstrated by
B1 Structure
B1.3.1
B1.3.2
B1.3.3 (a, b, f, j, m, q)
B1.3.4 (a, b, c, d, e)
ACCEPTABLE SOLUTION
B1/AS1: NZS 3604:2011, clause
2.3.9.3.
NZS 3604:2011, clause 2.3.9.3 requires glue laminated timber to
be manufactured in accordance with AS/NZS 1328 (Parts 1, 2).
Prowood Ltd third party certied, AsureQuality Engineered
Wood Products Programme: AS/NZS 1328:1998 (parts 1, 2).
AsureQuality is JAS-ANZ accredited.
B2 Durability
B2.3.1(a) B2.3.2(a)
ALTERNATIVE SOLUTION
AS/NZS1604.5, clause 1.9 requires the same characteristic
values for penetration and retention as dened in NZS
3640:2003.
Registered by Timber Preservers Association of Australia H1.2
(boron)
C6 Protection from Fire
C6.2
C6.3
C6.4
ALTERNATIVE SOLUTION
NZS 3603:2011, clause 9.4.2.
NZS 3603:1993, clause 9.4.2 species charring rate of radiata
pine and other timber species of approximately the same
density to be taken as 0.65 mm/min.
APA Evaluation of Char Rate (ASTM E119), TT-118 January 2015.
Glued laminated timber elements have a re performance
comparable to solid wood members of equivalent size; Timber
Industry Federation New Zealand Timber Design Guide 2007.
F2 Hazardous
Building Materials
F2.3.1
ALTERNATIVE SOLUTION.
NZTPC Best Practice Guideline
for the Safe Use of Timber
Preservatives & Anti-sapstain
Chemicals. Establishes drying &
ash o requirements.
Subject to Prowood treatment protocol and Prowood health
and safety plan.
TBB audited manufacturing/treatment process.
1. The Compliance Statement is the pass holder’s statement that they have met their obligations under s14G(2) of the Building Act 2004.
By signing this pass™ the signatory conrms that, in
respect of the subject of this pass™, the company has met
their s14G obligations under the Building Act 2004.
VERSION:
DATE:
Note: Uncontrolled in printed format.
NAME:
John Woodman
POSITION:
Managing Director
Signed on behalf of Prowood Ltd:
283 Waiwhero Road, Motueka info@prowoodnz.com 03 526 7436 www.prolamnz.com
This Product Assurance Supplier Statement (pass™) has been prepared by TBB in accordance with MBIE PTS guidelines and the recommendations of s9.2,
Determination No. 2019-011 (issued 12 April 2019). TBB is ISO9001:2016 certied. Copyright © 2017, The Building Business Limited (TBB). All rights reserved.
v1.0
07/06/2019
USEFUL
INFORMATION
For information on the design, installation and
maintenance of Smartframe, and for our warranty,
refer to www.prolamnz.com.
OTHER CERTIFICATIONS
HELD BY PROWOOD LTD
The following certications and approvals are held by
Prowood Ltd.
Certicate of Registration of Preservative Treatment
& Allocated Brand Timber Treatment Plant
Registration Authority;
709 11 H1.2, 614 11 H1.2
PROLAM SMARTFRAME LVL15
LAMINATED VENEER LUMBER
PURPOSE
Prowood Ltd supplies Prolam Smartframe LVL15 (Smartframe) for use as structural timber
beams and studs in buildings.
PROLAM SMARTFRAME EXPLAINED
Smartframe is laminated veneer lumber manufactured from Douglas Fir.
It is manufactured to AS/NZS 4357:2005 under an SAIGlobal StandardsMark licence.
It is supplied boron treated to H1.2 or untreated and is supplied in the following nished
dimensions.
Widths (mm): 90, 120, 140, 190, 240, 290
Depth (mm): 45 mm
Stock lengths (m): 3.6, 4.8, 5.4, 6.0, and 7.2
pass™ no:
Expires:
For further assistance
please contact:
03 526 7436
info@prowoodnz.com
www.prolamnz.com
SCOPE AND LIMITATIONS OF USE
Scope Limitations
Building
To the requirements of NZS 3604:2011 or NZS 3603:1993,
and in accordance with Smartframe span tables.
Within the building envelope.
Smartframe must not be exposed to the environment for more
than 90 days.
Where the Smartframe is to be le exposed or used in a
moisture laden environment it must be protected with an
impervious coating.
In applications where NZ Building Code Clause C3 obligations
for Fire aecting areas beyond the source apply.
The use of Smartframe must be specically designed by a
re engineer.
VERSION:
19013
06/2020
v1.0
PERFORMANCE CLAIMS
If designed, installed and maintained in accordance with the all Prowood Ltd requirements, Smartframe will comply with or contribute
to compliance with the following performance claims.
SOURCES OF INFORMATION
The following information was relied upon to prepare this pass.
SAIGlobal StandardsMark Licence Certicate Number
SMKB25220 Tilling Timber Pty Ltd.
IVS Timber Testing Report 39361 19/11/18.
IVS Labs Analysis Report R32568 Boron Preservative in Timber
5/12/18.
AS/NZS 4357:2005 Structural laminated veneer lumber.
NZS 3603:1993 Timber structures.
NZS 3604:2011 Timber-framed buildings.
NZS 3640:2003 Chemical preservation of round and
sawn timber.
AS/NZS 1604.4:2012 Specication for preservative treatment
Part 4; Laminated Veneer Lumber (LVL).
NZ Building
Code clauses
BASIS OF COMPLIANCE
Compliance statement
1
Demonstrated by
B1 Structure
B1.3.1
B1.3.2
B1.3.3 (a, b, f, j, m, q)
B1.3.4 (a, b, c, d, e)
ACCEPTABLE SOLUTION
B1/AS1: NZS 3604:2011, clause
2.3.9.2.
NZS 3604:2011, clause 2.3.9.2 requires LVL to be
manufactured in accordance with AS/NZS 4357.
Smartframe manufactured to AS/NZS 4357:2005 under
SAIGlobal StandardsMark licence.
SAIGlobal is JAS-ANZ accredited.
B2 Durability
B2.3.1(a)
B2.3.2(a)
ALTERNATIVE SOLUTION
AS/NZS1604.4:2012, clause 1.9 requires same characteristic
values for penetration and retention as dened in NZS
3640:2003.
In accordance with Prowood treatment protocol to AS/NZS
1604.4:2012 and NZS 3640:2003.
Passed IVS Labs penetration and retention testing of LVL
samples to AS/NZS 1605:2018, parts 1 and 2.
C6 Protection from Fire
C6.2
C6.3
C6.4
ALTERNATIVE SOLUTION
NZS 3603:2011, clause 9.4.2.
NZS 3603:1993, clause 9.4.2 species charring rate of radiata
pine and other timber species of approximately the same
density to be taken as 0.65 mm/min.
APA Evaluation of Char Rate (ASTM E119), TT-118 January 2015.
F2 Hazardous
Building Materials
F2.3.1
ALTERNATIVE SOLUTION.
NZTPC Best Practice Guideline
for the Safe Use of Timber
Preservatives & Anti-sapstain
Chemicals. Establishes drying &
ash o requirements.
In accordance with Prowood treatment protocol and
Prowood health and safety plan.
TBB audited manufacturing/treatment process.
1. The Compliance Statement is the pass holder’s statement that they have met their obligations under s14G(2) of the Building Act 2004.
By signing this pass™ the signatory conrms that, in
respect of the subject of this pass™, the company has met
their s14G obligations under the Building Act 2004.
VERSION:
DATE:
Note: Uncontrolled in printed format.
NAME:
John Woodman
POSITION:
Managing Director
Signed on behalf of Prolam Ltd:
283 Waiwhero Road, Motueka info@prowoodnz.com 03 526 7436 www.prolamnz.com
This Product Assurance Supplier Statement (pass™) has been prepared by TBB in accordance with MBIE PTS guidelines and the recommendations of s9.2,
Determination No. 2019-011 (issued 12 April 2019). TBB is ISO9001:2016 certied. Copyright © 2017, The Building Business Limited (TBB). All rights reserved.
v1.0
07/06/2019
USEFUL
INFORMATION
For information on the design, installation and
maintenance of Smartjoists, and for our warranty, refer to
www.prolamnz.com.
OTHER CERTIFICATIONS HELD
BY PROWOOD LTD
The following certications and approvals are held by
Prowood Ltd.
Certicate of Registration of Preservative Treatment &
Allocated Brand Timber Treatment Plant Registration
Authority;
709 11 H1.2 (13/7/18), 614 11 H1.2 (5/7/18)
PROLAM SMARTJOISTS
PURPOSE
Prowood Ltd supplies Prolam Smartjoists for use as raers and oor joists in
buildings.
PROLAM SMARTJOISTS EXPLAINED
Smartjoists are manufactured from graded Douglas Fir LVL15 anges and
Oriented Strand Board webs bonded together with an exterior, heat durable
adhesive that complies with ASTM D5055.
They are supplied boron treated to H1.2 or untreated and are available in:
Overall height Flange width
240 mm 70 mm
300 mm 70mm
360 mm 90 mm
pass™ no:
Expires:
For further assistance
please contact:
03 526 7436
info@prowoodnz.com
www.prolamnz.com
SCOPE AND LIMITATIONS OF USE
Scope Limitations
Building
In conjunction with timber or lightweight steel structural
framing and in accordance with the Smartjoist span tables.
Where the framing complies with the NZ Building Code or
for existing buildings, where the designer and/or installer
have established that the existing structure is suitable for
the intended building work.
Fixing material to be in accordance with section 4,
NZS 3604:2011.
Within the building envelope where hazard class H1.2 or
less applies.
The Smartjoist must not be exposed to the environment
for more than 90 days.
Where the Smartjoist is to be le exposed or used in a
moisture laden environment it must be protected
with an impervious coating.
VERSION:
19013
06/2020
v1.0
PERFORMANCE CLAIMS
If designed, installed and maintained in accordance with all of Prowood Ltd requirements, Smartjoists will comply with or
contribute to compliance with the following performance claims.
SOURCES OF INFORMATION
The following information was relied upon to prepare this pass.
ICC-ES and APA Joint Evaluation Report ESR-1225 Pacic
Woodtech Corporation PWI Joists 10/17.
IVS Timber Testing Report 39361 19/11/18.
IVS Labs Analysis Report R32568 Boron Preservative in
Timber 5/12/18.
NZS 3603:1993 Timber structures.
NZS 3604:2011 Timber-framed buildings.
NZS 3640:2003 Chemical preservation of round
and sawn timber.
AS/NZS 1604:2012 Specication for Preservative treatment
(parts 2 & 4).
NZ Building
Code clauses
BASIS OF COMPLIANCE
Compliance statement
1
Demonstrated by
B1 Structure
B1.3.1
B1.3.2
B1.3.3 (a, b, f, j, m, q)
B1.3.4 (a, b, c, d, e)
ALTERNATIVE SOLUTION
IBC section 2303.1.2 and 2015 IRC
section R502.1.2 and 2012, 2009
and 2006 IRC Section R502.1.4 for
allowable stress design.
Evaluated by ICC-Evaluation Service (ICC-ES) and APA
(The Engineered Wood Association) as manufactured
in accordance with IBC and IRC and in accordance with
the approved Pacic Woodtech Corporation I-Joist
Quality Control Manual.
ICC-ES is accredited by the American National
Standards Institute and by the Standards of Council
of Canada under ISO/IEC Guide 17065, Conformity
Assessment – Requirements for Bodies Certifying
Products, Processes, and Services.
B2 Durability
B2.3.1(a) B2.3.2(a)
ALTERNATIVE SOLUTION
AS/NZS1604:2012, clause 1.9 requires same
characteristic values for penetration and retention as
dened in NZS 3640:2003.
Subject to Prowood treatment protocol to AS/NZS
1604:2012 and NZS 3640:2003.
F2 Hazardous
Building Materials
F2.3.1
ALTERNATIVE SOLUTION.
NZTPC Best Practice Guideline
for the Safe Use of Timber
Preservatives & Anti-sapstain
Chemicals. Establishes drying &
ash o requirements.
Subject to Prowood treatment protocol and Prowood
health and safety plan.
TBB audited manufacturing/treatment process.
1. The Compliance Statement is the pass holder’s statement that they have met their obligations under s14G(2) of the Building Act 2004.
By signing this pass™ the signatory conrms that, in
respect of the subject of this pass™, the company has met
their s14G obligations under the Building Act 2004.
VERSION:
DATE:
Note: Uncontrolled in printed format.
NAME:
John Woodman
POSITION:
Managing Director
Signed on behalf of Prowood Ltd:
283 Waiwhero Road, Motueka info@prowoodnz.com 03 526 7436 www.prolamnz.com
This Product Assurance Supplier Statement (pass™) has been prepared by TBB in accordance with MBIE PTS guidelines and the recommendations of s9.2,
Determination No. 2019-011 (issued 12 April 2019). TBB is ISO9001:2016 certied. Copyright © 2017, The Building Business Limited (TBB). All rights reserved.
v1.0
07/06/2019