Window/Door Replacement and/or Impact Shutter Permit Form
A Layout Diagram that identifies & locates each replacement Window/Door
or Shutter install must be provided with this Permit Form.
Project Address: ___________________________________________________________________________________
Owner’s Name: _________________________________ Contractor’s Name: ____________________________
Applicant/Contact Name: ____________________________ Contact Phone #: ______________________________
Florida Product Approval Schedule: Identify location of the product(s) on your Layout Diagram
Per PC Gulf Beaches - CCC: Where required, glazing installed shall meet the requirements for marine turtle nesting areas.
Impact Non-Impact Florida Product Approval # or NOA #
Layout Diagram
Location # or #'s
The Exposure Category is determined by the structures distance from the shoreline of open water.
Link to P.C. map with measuring tool: https://egis.pinellas.gov/apps/webgispublic/
For additional information see the Exposure Category Diagram in the Window/Door Permit Reference Guide.
Exposure B: a structure located at least 1,500 ft from the shoreline of open water
Exposure C: a structure located at least 600 ft from the shoreline of open water & less than 1,500 ft
Exposure D: a structure located within 600 ft of the shoreline of open water
1.) Select your Exposure & the opening(s) max.
height above grade for each floor level.
2.) Complete the FL-Product Approval Schedule
below: impact/non-impact, FL-# with the
specific decimal & Diagram Location #,
continue list on another page if necessary.
*FL-products specified must exceed the +/- C&C
pressures as calculated based on the FBC.*
145 mph Risk Category II
Max. C&C Pressures (0 - 15 ft. Hgt.)
_____ +27.6 psf / -36.3 psf (10sf wall Zone 5)
Max. C&C Pressures (15 - 20 ft. Hgt.)
_____ +29.4 psf / -38.7 psf (10sf wall Zone 5)
Max. C&C Pressures (20 - 25 ft. Hgt.)
_____ +30.8 psf / -40.5 psf (10sf wall Zone 5)
Max. C&C Pressures (25 - 30 ft. Hgt.)
_____ +31.9 psf / -42.0 psf (10sf wall Zone 5)
Note: Component & Cladding (C&C) Pressures listed
are based on heights identified & a 10sf area at wall
Zone 5 (worst case).
**Contractor can calculate C&C pressures for increased heights & areas
not listed for wall Zones 4 & 5 as necessary and provide this information
on his Layout Diagram.**
145 mph Risk Category II
Max. C&C Pressures (0 - 30 ft. Hgt.)
_____ +22.8 psf / -30.0 psf (10sf wall Zone 5)
145 mph Risk Category II
Max. C&C Pressures (0 - 15 ft. Hgt.)
_____ +33.5 psf / -44.1 psf (10sf wall Zone 5)
Max. C&C Pressures (15 - 20 ft. Hgt.)
_____ +35.3 psf / -46.5 psf (10sf wall Zone 5)
Max. C&C Pressures (20 - 25 ft. Hgt.)
_____ +36.7 psf / -48.3 psf (10sf wall Zone 5)
Max. C&C Pressures (25 - 30 ft. Hgt.)
_____ +37.8 psf / -49.8 psf (10sf wall Zone 5)