R
Job Name:
Job Number:
Model Numbers:
Page
SPECIFICATION SUBMITTAL
sgshade-2 06.30.04
®
Window Treatment Wallstations
TM
SG-3WN-___-___
3-Button Window Treatment
Wallstation
Color and Engraving Codes
Engraving
SG-3WN-WH-E01
SG-3WI-WH-___
(Insert version)
LEDs
Description
• Used to control one or more window treatment
zones simultaneously on GRAFIK Eye 3000 and
4000 Series Control Units.
• Can control Sivoia QED
TM and AC Motorized
Window Treatments.
• Large, rounded buttons are easy to use.
• Backlit buttons with on-button engraving make it
easy to find and operate the control in low light
conditions.
• Optional button engraving is angled up to the eye
for easy reading.
• Pressing the Open button once will cause the
window treatments move to their fully open
position. If the Open button is pressed again while
the window treatments are opening, the
movement of the window treatments will stop.
• Pressing the Close button once will cause the
window treatments move to their fully closed
position. If the Close button is pressed again while
the window treatments are closing, the movement
of the window treatments will stop.
• Pressing Stop will stop the movement of the
window treatments.
• The LEDs next to each button are used during
programming and provide feedback when the
buttons are pressed. For Sivoia QED, the LEDs
provide feedback of the current Sivoia QED
preset.
• Works with GRAFIK Eye 3000 and 4000 Series
Control Units. Can be set to control up to 8
groups of Sivoia QED Window Treatments.
• For each group of Sivoia QED Window
Treatments, a GRAFIK Eye Sivoia QED Controller
is needed.
Finish and Engraving Options
• Available with button engraving.
• Standard and Non-Standard Text Engraving is
available. For more details, please visit the
seeTouch website at www.lutron.com/seetouch.
1
R
Job Name:
Job Number:
Model Numbers:
Page
SPECIFICATION SUBMITTAL
sgshade-6 06.30.04
®
Window Treatment Wallstations
TM
4
3
2
1
Dimensions
Front View
Specifications
Power
Low-voltage type Class 2 (PELV). Operating voltage:12/24VDC.
Key Design Features
• Field-changeable button and faceplate assemblies allow easy customization.
• Front accessible DIP switches allow change of address without removing the
unit from the wall.
• Meets IEC 801-2. Tested to withstand 15kV electro-static discharge without
damage or memory loss.
• Faceplate snaps on with no visible means of attachment.
• Available as an “insert” style control for multi-ganging.
• Can be ganged to share a common faceplate with NovaT*
® and Vareo®
Dimmers. To order new Wallplates for multi-ganging, specify “R3” openings
in a Lutron NovaT* multi-gang FB (fins broken) Series model number.
• Use Button Replacement Kits to change color, button configuration, or
engraving.
• Button Replacement Kits may also be used to convert between non-insert
and insert configurations.
System Communications and Capacity
• Low-voltage type Class 2 (PELV) wiring connects Wallstations to Control Units
and other components.
• Up to 8 Control Units and 16 total Wallstations and/or Control Interfaces may
be connected for a total of 24 control points.
Terminals
Accept up to two #18 AWG (1.0mm
2
) typical.
Environment
32-104°F (0-40°C). Relative humidity less than 90% non-condensing.
Mounting
Typical backbox dimensions: 95mm (3.74”) high, 55mm (2.17”) wide, 70mm
(2.75”) deep.
Side View
Back View
Terminals
for Class 2
(PELV)
Wiring
1 1/16”
(27 mm)
2 3/4”
(70 mm)
4 9/16”
(116 mm)
5/16”
(8 mm)
3/4”
(19 mm)
2
R
Job Name:
Job Number:
Model Numbers:
Page
SPECIFICATION SUBMITTAL
sgshade-7 06.30.04
®
Window Treatment Wallstations
TM
Matte Finishes
White WH
Ivory IV*
Beige BE
Gray GR*
Brown BR
Black BL
* GR, IV not currently backlighted
Color/Finish and Customizing Information
Color/Finish
Multi-ganging
Gloss Finishes
Available with Insert (I) style controls only.
Ship with Claro
® faceplates.
White GWH
Light Almond GLA
• Order Insert (I) style controls.
• To order new Wallplates for multi-ganging, specify
“R3” openings in a Lutron NovaT*
® multi-gang FB
(fins broken) Series model number.
Metal Finishes
With Black Plastic Buttons (Standard)
Bright Brass BB
Bright Chrome BC
Bright Nickel BN
Satin Brass SB
Satin Chrome SC
Satin Nickel SN
Antique Brass QB
Antique Bronze QZ
Anodized Aluminum Finishes
Clear CLA
Black BLA
Brass BRA
Backlighting Notes:
Illuminated text (translucent text
on buttons) is available for these
colors: BL and BR (including all
metal finishes).
Illuminated buttons (with black
text on buttons) are available for
these colors: WH, BE, GR, WH*,
GLA*.
* Insert (I) style controls only
Use Button Replacement Kits to change: colors, button
configuration, engraving, between insert and non-insert versions.
Each Kit includes
an adapter, button
assembly, and
wallplate
Non-Insert Kit
Examples:
Wallplate for 2 seeTouch Wallstations,
Model # NT-R3-R3-FB-(color)
Wallplate for other Lutron controls and
2 seeTouch Wallstations,
Model # NT-T8-R3-R3-FB-(color)
Note: New button inserts are not included with
multi-ganging Wallplates.
Button Replacement Kits
Insert Kit
3
R
Job Name:
Job Number:
Model Numbers:
Page
SPECIFICATION SUBMITTAL
sgshade-8 06.30.04
®
Window Treatment Wallstations
TM
DIP Switches
• Set DIP switches 1-4 to give the Wallstation a
unique system address from 1 to 16.
• DIP Switches 5 -10 are set at the factory. Do
not change switches 5 - 9.
• DIP switch 10 controls the button backlight.
• Refer to Installation Guide for more details.
Low-voltage Class 2 (PELV) Wiring
• Use low-voltage Class 2 (PELV) wiring to daisy-chain
Wallstations to Control Units and other components.
• Make connections inside the wallbox or in a
switch/junction box with a maximum wire length of 8
feet (2.5m) from the link to the Wallstation.
When used with GRAFIK Eye 3000 Control Units
• Two #18 AWG (1.0mm
2
) conductors for common
(terminal 1) and 12VDC (terminal 2). Ensure that the
terminal 2 connection is wired correctly. Refer to
GRAFIK Eye 3000 Series Specification Submittal.
• One shielded, twisted pair #18 AWG (1.0mm
2
) for
data link (terminals 3 and 4).
When used with GRAFIK Eye 4000 Control Units
• Two #12 AWG (2.5mm
2
) conductors for common
(terminal 1) and 24VDC (terminal 2). These won’t fit
in terminals. Connect as shown.
• One shielded, twisted pair #18 AWG (1.0mm
2
) for
data link (terminals 3 and 4).
• Connect Drain/Shield as shown. Do not connect to
Ground (Earth) or Wallstation. Connect the bare drain
wires and cut off the outside shield.
Note: Use appropriate wire connecting devices as
specified by local codes.
4
3
2
1
Data Link - (1) twisted,
shielded pair #18 AWG
(1.0mm
2
)
3: MUX
4: MUX
Class 2/PELV
Control wiring
1: Common
2: 24VDC
D: Drain/Shield
Wallstation Rear View
(2) #12 AWG
(2.5mm
2
)
(2) #12 AWG
(2.5mm
2
)
(1) #18 AWG
(1.0mm
2
)
(1) #18 AWG
(1.0mm
2
)
Wallstation Installation
Address
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
DIP Switch Settings
1 2 3 4
Reserved for GRX-PRG, if present on link.
4