JOB NAME LOCATION
CONTRACTOR ORDER NO.
ENGINEER SUBMITTED FOR APPROVAL RECORD
DATE OUTDOOR UNIT MODEL NO.
MODEL NO. INDOOR COIL MODEL NO.
SUBMITTAL SHEET FOR RH1T
2 TO 5 NOMINAL TON [7.3 TO 17.6 kW] AIR HANDLERS
FEATURES FOR RH1T
■ RH1T/RH2T feature a Constant Torque motor (ECM) which provides
enhanced SEER performance with most Rheem outdoor units.
■ Versatile 4-way convertible design for upflow, downflow, horizontal left
and horizontal right applications.
■ Factory-installed indoor coil.
■ Sturdy cabinet construction with 1.0 inch [25.4 mm] offoil faced insulation
for excellent sound and insulatingcharacteristics.
■ Field-installed auxiliary electric heater kits provide exact heat for indoor
comfort. Kits include circuit breakers which meet U.L. and cUL require-
ments for service disconnect.
■ 1
1
/2 ton [5.3 kW] through 5 ton [17.6 kW] models are between 42
1
/2 to 57
inches [1080 to 1448 mm] tall and 22 inches [559 mm] deep.
■ All models meet or exceed 330 to 400 CFM [156 to 189 L/s] per ton at
.3 inches [.7 kPa] of external static pressure.
■ Enhanced airflow up to .7" external static pressure.
■ Evaporator is constructed of aluminum fins bonded to internally grooved
aluminum tubing.
■ Suitable for application in mobile homes.
[ ] Designates Metric Conversions
UNIT DATA
COOLING PERFORMANCE
TOTAL CAPACITY*..................
_______
MBH [kW]
SENSIBLE CAPACITY*............
_______
MBH [kW]
OUTDOOR DESIGN TEMP. ....
_______
°F [°C] DB
TOTAL SUPPLY AIR ................
_______
CFM [L/s]
TEMP. OF AIR ENTERING
EVAPORATOR COIL............
_______
°F [°C] DB
_______
°F [°C] WB
POWER INPUT REQUIREMENT........
_______
kW
(*uses blower motor heat)
HEATING PERFORMANCE
TOTAL CAPACITY*..................
_______
MBH [kW]
OUTDOOR DESIGN TEMP. ....
_______
°F [°C] DB
TEMP. OF AIR ENTERING
EVAPORATOR COIL............
_______
°F [°C] DB
ELECTRIC HEAT CAPACITY ............
_______
kW
POWER INPUT REQUIREMENT........
_______
kW
(*uses blower motor heat)
SUPPLY AIR BLOWER PERFORMANCE
TOTAL AIR SUPPLY ................
_______
CFM [L/s]
TOTAL RESISTANCE EXTERNAL
TO UNIT......................................
_______
IWG
BLOWER SPEED ..........................
_______
RPM
POWER OUTPUT REQUIREMENT ..
_______
BHP
MOTOR RATING ........................
_______
HP [W]
POWER INPUT REQUIREMENT........
_______
kW
ELECTRICAL DATA
POWER SUPPLY ..................
______________ Hz
TOTAL UNIT AMPACITY................
_______
AMPS
MINIMUM WIRE SIZE ....................
_______
AWG
MAXIMUM OVERCURRENT DEVICE
FUSES/HACR BREAKER ..........
_______
AMPS
CLEARANCES
SERVICE ACCESS FRONT 24" [609.6 mm]
FORM NO. X33-1557