SUBMITTAL COVER SHEET
Quantity
Unit Designation
Model No.
Total Cooling
Sensible Cooling
Air Ent. Evaporator
Air Lvg. Evaporator
Heating Input
Heating Output
CFM/ESP
EER/SEER
Electrical
Minimum Ampacity
Min.-Max. Breaker
Net Unit Weight
Accessory
Catalog Form Number
ACCESSORIES: NOTES:
PRINTED IN U.S.A 01/12 QG FORM NO. M11-1640
PROJECT NAME
LOCATION
ARCHITECT
ENGINEER
CONTRACTOR
SUBMITTED BY DATE
UNIT SUMMARY
UNIT DATA
COOLING PERFORMANCE
EFFICIENCY ..................................
_______
SEER
TOTAL CAPACITY*....................
_______
MBH [kW]
SENSIBLE CAPACITY* ..............
_______
MBH [kW]
OUTDOOR DESIGN TEMP. ........
_______
°F [°C] DB
TEMP. OF AIR ENTERING
EVAPORATOR COIL ..............
_______
°F [°C] DB
_______
°F [°C] WB
POWER INPUT REQUIREMENT ..........
_______
kW
(*uses blower motor heat)
HEATING PERFORMANCE
EFFICIENCY ..................................
_______
HSPF
TOTAL CAPACITY*....................
_______
MBH [kW]
OUTDOOR DESIGN TEMP. ........
_______
°F [°C] DB
TEMP. OF AIR ENTERING
EVAPORATOR COIL ..............
_______
°F [°C] DB
SUPPLY AIR BLOWER PERFORMANCE
TOTAL AIR SUPPLY ..................
_______
CFM [L/s]
TOTAL RESISTANCE EXTERNAL
TO UNIT........................................
_______
IWG
BLOWER SPEED..............................
_______
RPM
POWER OUTPUT REQUIREMENT ....
_______
BHP
MOTOR RATING ..........................
_______
HP [W]
POWER INPUT REQUIREMENT ..........
_______
kW
ELECTRICAL DATA
POWER SUPPLY..........................
____________ Hz
TOTAL UNIT AMPACITY..................
_______
AMPS
MINIMUM WIRE SIZE ......................
_______
AWG
MAXIMUM OVERCURRENT DEVICE
FUSES/HACR BREAKER ............
_______
AMPS
CLEARANCES
ACCESS SIDE 24" [609.6 mm]
AIR INLETS 12" [304.8 mm]
ABOVE UNIT 60" [1524 mm]
JOB NAME LOCATION
CONTRACTOR ORDER NO.
ENGINEER UNIT MODEL NO.
SUBMITTED FOR APPROVAL RECORD COIL MODEL NO.
DATE AIR HANDLER MODEL NO.
SUBMITTAL SHEET FOR RP14 SERIES
1
1
/2 TO 5 NOMINAL TON [5.28 TO 17.6 kW], 14 SEER
HEAT PUMP UNITS
FORM NO. X33-1552
FEATURES FOR RP14 SERIES HEAT PUMP UNITS
New composite base pan – dampens sound, captures louver panels, eliminates corrosion
and reduces number of fasteners needed
Improved tubing design – reduces vibration and stress, making unit quieter and reducing
opportunity for leaks
Optimized defrost characteristics – decrease defrosting and provide better home comfort
Powder coat paint system – for a long lasting professional finish
Optimized reversing valve sizing – improves shifting performance for quieter unit
operation and increased life of the system
Enhanced mufflers – help to dissipate vibration energy for quieter unit operation
Scroll compressor – a sound abating feature added to the compressor significantly
reduces noise when system transitions in and out of defrost mode
Modern cabinet aesthetics – increased curb appeal with visually appealing design
Curved louver panels – provide ultimate coil protection, enhance cabinet strength, and
increased cabinet rigidity
Optimized fan orifice – optimizes airflow and reduces unit sound
Rust resistant screws – confirmed through 1500-hour salt spray testing
PlusOne™ Expanded Valve Space – 3"-4"-5" service valve space – provides a minimum
working area of 27-square inches for easier access
Integrated heat pump lift receptacle – allows standard CPVC stands to be inserted into
the base
PlusOne™ Triple Service Access – 15" wide, industry leading corner service access –
makes repairs easier and faster. The two fastener removable corner allows optimal
access to internal unit components. Individual louver panels come out once fastener is
removed, for faster coil cleaning and easier cabinet reassembly
Diagnostic service window with two-fastener opening – provides access to the TXV
valves and the heat pump reversing valve before opening the unit.
External gauge port access – allows easy connection of
“low-loss” gauge ports
Single-row condenser coil – makes unit lighter and allows thorough coil cleaning to maintain
“out of the box” performance
35% fewer cabinet fasteners and fastener-free base – allow for faster access to internal
components and hassle-free panel removal
Service trays – hold fasteners or caps during service calls
QR code – provides technical information on demand for faster service calls
Fan motor harness with extra-long wires – allows unit top to be removed without discon-
necting fan wire
ACCESSORIES/OPTIONS
Compressor Crankcase Heater ....................................................................................
Low Ambient Control (Model No. RXAD-A08)........................................................................
Compressor Sound Cover......................................................................................................
Compressor Hard Start Kit ....................................................................................................
Classic Top Cap w/label (91-101123-21) ..............................................................................
RP14 18, 24, 30,
36, 42, 48, 60
Before proceeding with installation, refer
to installation instructions packaged
with each model, as well as complying
with all Federal, State, Provincial, and
Local codes, regulations, and practices.
Rheem Sales Company, Inc.
P.O. Box 17010, Fort Smith, AR 72917
“In keeping with its policy of continuous progress and product improvement, Rheem reserves the right to make changes without notice.
PRINTED IN U.S.A. 3-15 QG FORM NO. X33-1552
Supersedes Form No. X33-1209
Unit Dimensions
MODEL
NUMBER
OPERATING SHIPPING
H (Height) L (Length) W (Width) H (Height) L (Length) W (Width)
INCHES mm INCHES mm INCHES mm INCHES mm INCHES mm INCHES mm
RP1418 25 635 29.75 755 29.75 755
26.75 679 32.38 822 32.38 822
RP1424 25 635 29.75 755 29.75 755
26.75 679 32.38 822 32.38 822
RP1430 25 635 29.75 755 29.75 755
26.75 679 32.38 822 32.38 822
RP1436 27 685 33.75 857 33.75 857
28.75 679 36.38 924 36.38 924
RP1442 27 685 33.75 857 33.75 857
28.75 679 36.38 924 36.38 924
RP1448 35 889 33.75 857 33.75 857
36.75 933 36.38 924 36.38 924
RP1460 39 990 35.75 908 35.75 908
40.75 1035 38.38 975 38.38 975
[ ] Designates Metric Conversions
ST-A1226-02-00