1
www.utopialightingus.com UTOPIA LIGHTING reserves the right to change specications, drawings, dimensions without prior notice. Visit our website for the latest product information.
6” ARCHITECTURAL NEW CONSTRUCTION FRAME
LAD6A
FEATURES:
• Heavy gauge die formed galvanized steel mounting
frame trim clips to mount open conical shape
reector.
• Vertically adjustable mounting brackets that use
conduit or C channel (please see drawing for
recommended C channel size on the next page).
Provides 3-3/4” total adjustment.
• C channel is optional, not included as std.
• Post installation adjustment possible from above or
below the ceiling.
• Maximum 1-1/2” ceiling thickness.
• Reectors are optically designed to maximize lumen
output and to provide superior glare control.
• Non-insulated ceilings or where insulation can be
kept 3” from all side of housing.
JUNCTION BOX:
• Galvanized steel junction box with seven 1/2”
knockouts, four pryouts, and snap on cover.
• Electrical connections are made through a single
junction box door.
• Access to junction box from below ceiling after
removal of reector for easy maintenance.
LED:
• CREE LED technology.
• 50,000 hours.
• 4000K color temperature standard.
• 16W, 25W, 38W, 50W, 70W, 100W LED.
• Color Rendering Index: > 90
ELECTRICAL:
• Input voltage: 120-277V
• 3 in 1 dimming: Triac (120V only), 0-10V (dim to 1%,
120-277V), ELV (120V only).
• Thermal protection.
• Surge protection (3kV line to line, 6kV line to earth).
• Protections: Output open load, over-current and
short-circuit(hiccup), and over-temperature with auto
recovery.
• Conducted and radiated EMI: Compliant with FCC
CFR Title 47 Part 15 Class B (120 Vac)/ Class A
(277 Vac) and EN55015 (CISPR 15) at 220/230/240
Vac.
• <ELCU-200>
• Guarantees emergency lighting remains ON or is
turned on when power to the control device is lost.
• Interfaces with re alarm panel or security system.
• “Watchdog” feature allows emergency loads to be
controlled in tandem with normal power loads.
• UL listed for use in emergency circuits.
LISTING:
• UL/CUL listed for damp locations with covered
ceiling.
• UL/CUL wet location listed.
• Listed to UL 1598 and UL 8750.
• Minimum 75°C supply conductors.
• CSA certied to US.
• Energy Star certied.
5
• 5 years limited warranty.
• 10 years limited warranty (optional).
8, 9
• ARRA compliant (optional).
APPLICATION
6” Horizontal architectural frame-in is design
for high quality application with lens. Ideal
for commercial, retail, conference rooms and
hospital where architectural LED downlight
xture is required.
Revised: 12.21.2020
WET
LOCATION
Dimensions
A: 10-7/8” (276)
B: 6-1/4” Dia. (158)
A B
1
Dimensions (16W, 25W, 38W, 50W)
C: 5-3/8” (136)
D: 6-5/16” Dia. (160)
E: 11-7/8” (302)
F: 5-3/4” (146)
G: 1-1/2” (38)
H: 7-11/16” (195.6)
Dimensions (70W, 100W)
C: 5-3/8” (136)
D: 6-5/16” Dia. (160)
E: 11-7/8” (302)
F: 5-3/4” (146)
G: 1-1/2” (38)
I: 8-7/8” (224.6)
C
C
H
I
D
D
E
E
F
F
G
G
All dimensions are in inches.
Drawings are for dimensional detail information only.
Recommended C Channel Bar
part# CHB24 (optional)
1-1/2
(37.83)
1/16
(12.25)
25-3/16
(640)
Project Name: