Inspector: Mark Adair, Pristine
Cover Page
Pristine 3 Meadow Ct, Champaign, IL
Pristine 3 Meadow Ct, Champaign, IL
Page 1 of 50
Table Of Contents
Table Of Contents
Report Summary 3-14
General Information 15
Lots & Grounds 16
Roof 17
Exterior 18
Garage 19-21
Electric Service 22
Electric Panel 23
Electric Panel 2 24
Air Conditioning 25-26
Heating System 27-28
Plumbing 29
Water Heater 30
Interior 31-32
Laundry 33-34
Kitchen 35-36
Bathroom 37-38
North Bathroom 39-40
Bedrooms 41-42
Bedroom 2 43
Bedroom 3 44-45
Bedroom 4 46
Areas 47
Pristine 3 Meadow Ct, Champaign, IL
Page 2 of 50
Fireplace/Wood Stove 48
Structural Components 49
Glossary 50-51
Pristine 3 Meadow Ct, Champaign, IL
Page 3 of 50
Report Summary
Report Summary
On this page you will find a brief summary of any concerns of the inspection, as they relate to Safety
and Function. Examples would be bare electrical wires or active drain leaks. The complete list of
items noted is found throughout the body of the report, including Normal Maintenance items along
with items that may not have been required when the house was built, but are a good idea to
implement. Be sure to read your entire report!
For your safety and liability, we recommend that you hire only licensed contractors when having any
work done. This is important because our inspection does not tacitly approve, endorse, or guarantee
the integrity of any work that was done, and latent defects could exist.
Depending upon your needs and those who will be on this property, items listed in the body of the
report may also be a concern for you; be sure to read your Inspection Report in its entirety.
PRISTINE STOLEN TEMPLATE
Roof
Page 17 Item: 3 Flashing 3.1. Improper flashing installation was observed. Flashing
material is supposed to be located under the shingles, not
laying mostly on top of the shingles. Repairs are
recommended.
Garage
Page 19 Item: 2 Exterior Cladding 2.1. Soil / siding contact was observed, so grade changes are
recommended. Soil or landscape material should not touch
the siding as it can allow excessive moisture transfer into the
wall cavity. Also, it can allow easy and undetected entry of
wood destroying insects.
Page 19 Item: 3 Roof Covering 3.2. Damaged shingles observed. Repairs or replacement
shingles are recommended to prevent a roof leak.
3.3. Missing shingle tabs noted. Repairs are recommended to
correct this condition. Failure to properly replace the missing
tabs can result in a roof leak.
Seller replacing roof on garage
Pristine 3 Meadow Ct, Champaign, IL
Page 4 of 50
Page 20 Item: 5 Garage Doors 5.1. Damaged metal door panels observed during this
inspection. Repairs, or possibly a replacement door panel
appears to be needed at this time.
5.2. Safety cables were not observed running through the
middle of the extension type overhead door springs at this
time. I highly recommend the installation of safety cables
through the middle portion of the door springs to contain the
springs when they break. Failure to contain these springs can
result in personal injury or property damage.
Page 20 Item: 10 Exterior Door 10.1. Paint repairs appear to be needed at the trim, brick
mold, around the door. Scraping/prep work should be
completed prior to application of the paint. If any soft wood is
encountered during the preparation portion of the paint job,
wood repairs/replacement would need to be completed as
well.
10.2. Rust is showing on the metal door. Paint repairs are
recommended to ensure the metal is properly protected.
Pristine 3 Meadow Ct, Champaign, IL
Page 5 of 50
Electric Panel
Page 23 Item: 2 Electric Service
Panel
2.1. Panel not completely labeled. All breakers should be
labeled as a safety precaution.
Page 23 Item: 5 Breakers/Fuses 5.1. 30amp breakers installed (3) for a 120v circuits which is
unusual since most circuits are 15 or 20 amp. Further
evaluation is recommended and repairs made as needed.
5.2. Breaker is too large for the wire size connected to it.
Replace the breaker with a properly sized unit to correct this
potential fire safety hazard.
Electric Panel 2
Page 24 Item: 6 Panel Bonding 6.1. Improper bonding observed in the sub-panel box. Neutral
buss bars are not supposed to be bonded to the panel box in
a sub-panel. Repairs are recommended to correct this safety
hazard.
Pristine 3 Meadow Ct, Champaign, IL
Page 6 of 50
Air Conditioning
Page 25 Item: 3 Exterior Unit 3.1. Deteriorated insulation observed on the refrigerant lines
running from the exterior unit to the house.
Repairs/replacement of the insulation is recommended to
allow the A/C system to operate efficiently.
Page 25 Item: 6 Electrical
Disconnect
6.1. Improper sized breaker noted powering the external
condenser unit. The specifications listed on the
manufacturer's ID tag state the max breaker should be 20
amps. The outside disconnect is a breaker (with no over
current protection) and the breaker in the electrical panel is 30
amps. Repairs are recommended to ensure the outside unit is
properly protected.
Heating System
Page 27 Item: 2 Heating System 2.2. Improper sized breaker noted powering the furnace. The
specifications listed on the manufacturer's ID tag state the
max breaker should be 15 amps. The breaker in the electrical
panel is 20 amps. Repairs are recommended to ensure the
unit is properly protected.
Pristine 3 Meadow Ct, Champaign, IL
Page 7 of 50
Page 27 Item: 7 Flue 7.1. Condensation stains noted coming from the flue joints
indicating poor venting of the exhaust gases. Further
evaluation is recommended and repairs made as needed to
allow the unit to draft properly.
Page 28 Item: 8 Filter 8.1. Broken filter cover door noted. Repairs are
recommended.
8.2. Filter is dirty. A replacement filter should be installed as
soon as possible.
Water Heater
Page 30 Item: 1 Water Heater
Operation
1.2. Temperature of 139 degrees F was measured at a faucet.
Turning down the temperature control on the water heater is
recommended since normal water temperature should be
115-125. Most adults will suffer third-degree burns if exposed
to 150 degree water for two seconds. Burns will also occur
with a six-second exposure to 140 degree water or with a
thirty second exposure to 130 degree water. Even if the
temperature is 120 degrees, a five minute exposure could
result in third-degree burns.
Pristine 3 Meadow Ct, Champaign, IL
Page 8 of 50
Laundry
Page 33 Item: 2 Ceiling 2.1. Spot noted in the ceiling with infrared and were tested
and verified with my moisture meter. Further evaluation is
recommended and repairs to correct what appears to be a
moisture condition/water leak.
Page 33 Item: 5 Electrical 5.1. Missing cover plates noted. All switches and outlet boxes
should have covers installed on them at all times as a safety
precaution. If not repaired, a person can come into contact
with energized electrical components.
Kitchen
Page 36 Item: 14 Floors 14.1. Loose seams noted on the vinyl flooring. This is a trip
hazard, so repairs are recommended.
Pristine 3 Meadow Ct, Champaign, IL
Page 9 of 50
Bathroom
Page 37 Item: 7 Lights, Switches 7.1. Missing light cover noted. A replacement light cover is
recommended.
Page 37 Item: 10 Tub & Tub/Shower 10.1. Shower diverter does not properly route all of the water
flow up to the shower head. A replacement tub spout/diverter
valve unit appears to be needed.
North Bathroom
Page 39 Item: 2 Ceiling 2.1. Spot noted in the ceiling with infrared and were tested
and verified with my moisture meter. Further evaluation is
recommended and repairs to correct what appears to be a
moisture condition/water leak.
Page 39 Item: 3 Walls 3.1. Spot noted in the wall with infrared and were tested and
verified with my moisture meter. Further evaluation is
recommended and repairs to correct the moisture
condition/water leak.
works, user
error
Contracto
r check
on this
Pristine 3 Meadow Ct, Champaign, IL
Page 10 of 50
Page 39 Item: 5 Doors 5.1. Missing door was observed. Door installation is
recommended.
Bedrooms
Page 41 Item: 5 Doors 5.1. Paint repairs appear to be needed at the trim, brick mold,
around the (exterior door). Scraping/prep work should be
completed prior to application of the paint. If any soft wood is
encountered during the preparation portion of the paint job,
wood repairs/replacement would need to be completed as
well.
Page 41 Item: 6 Windows 6.1. Bottom sash falls down when released and will not stay
open on the west window. Repairs are recommended to allow
the window to function properly.
owner has door
owner added
storm door to
protect door from
water
Pristine 3 Meadow Ct, Champaign, IL
Page 11 of 50
Page 42 Item: 8 Electrical 8.1. Open grounds noted at the 3 prong outlets. Any 3-prong
outlet installed in a house is supposed to be properly
grounded. Repairs are recommended to correct this condition.
Bedroom 2
Page 43 Item: 8 Electrical 8.1. Open grounds noted at the 3 prong outlets. Any 3-prong
outlet installed in a house is supposed to be properly
grounded. Repairs are recommended to correct this condition.
Bedroom 3
Page 44 Item: 5 Doors 5.1. Hollow wood closet door has a hole. This type of door is
almost impossible to satisfactorily patch, so a replacement
door appears to be needed.
Pristine 3 Meadow Ct, Champaign, IL
Page 12 of 50
Page 44 Item: 8 Electrical 8.1. Open grounds noted at the 3 prong outlets. Any 3-prong
outlet installed in a house is supposed to be properly
grounded. Repairs are recommended to correct this condition.
Bedroom 4
Page 46 Item: 8 Electrical 8.1. Open grounds noted at the 3 prong outlets. Any 3-prong
outlet installed in a house is supposed to be properly
grounded. Repairs are recommended to correct this condition.
Fireplace/Wood Stove
Page 48 Item: 1 Fireplace / Stove 1.2. Cracked hearth material noted. Repairs are
recommended.
Pristine 3 Meadow Ct, Champaign, IL
Page 13 of 50
Structural Components
Page 49 Item: 2 Foundation
Observations
2.1. Crack noted on the wall which is 1/8" wide (south side).
Further evaluation is recommended by a qualified concrete
person and proper repairs made if needed.
contractor to
look at this
Pristine 3 Meadow Ct, Champaign, IL
Page 14 of 50
Property Address
3 Meadow Ct
Champaign, IL 61821
Client Information
Kirsten Moore
Agent Name and Company
-
Inspector
Mark Adair
IL Lic. #450010932
Company Information
Pristine
IL Lic. #451000932
Pristine 3 Meadow Ct, Champaign, IL
Page 15 of 50
General Information
1. Inspection End Time
Inspection End Time: 11:17 AM
2. File #:
File #: 22113
3. Fee
Inspection Fee: $375.00
Payment: Credit Card Online
4. Others Present
No Client or Agent Present
5. Year Built
Year Built: 1952
6. Entrance Faces
For the purpose of this report the building is considered to be facing West
7. Temperature
Temp: 75 Degrees F.
Rain
8. Ground/Soil Surface Condition
Wet
9. Utilities to the Structure
Electric, Natural gas and Water all on to property.
10. Occupied:
Occupied - Furnished
ACCESS TO SOME ITEMS SUCH AS: ELECTRICAL OUTLETS, WINDOWS, WALL/FLOOR
SURFACES, AND CABINET INTERIORS WAS RESTRICTED BY FURNITURE AND LARGE
QUANTITY OF PERSONAL BELONGINGS, AND SUCH ITEMS ARE EXCLUDED FROM THIS
INSPECTION REPORT.
Pristine 3 Meadow Ct, Champaign, IL
Page 16 of 50
Lots & Grounds
1. Driveway
Materials: Gravel
Observations:
1.1. Driveway appeared serviceable at time of inspection.
2. Walkways
Materials: Paver
3. Deck
Materials: Wood
Observations:
3.1. Maintenance: Clean and reseal the deck as part of routine maintenance.
3.2. Deck has been built very close to or directly on top of the soil, so I am unable to inspect the
framing/bottom portion of this deck structure.
4. Grading
Observations:
4.1. Minor slope
5. Vegetation
Trees, Shrubs, Grass
Pristine 3 Meadow Ct, Champaign, IL
Page 17 of 50
Roof
1. Location - Inspection - Limitations
Location: House
Method of Inspection: Walked The Roof Surface
2. Roof Covering
Materials: Composition Shingles
The roof is approximately 8 years old
3. Flashing
Materials: Metal • Neoprene
Observations:
3.1. Improper flashing installation was observed. Flashing material is supposed to be located under
the shingles, not laying mostly on top of the shingles. Repairs are recommended.
4. Skylights
Observations:
4.1. Not Present
5. Plumbing Vents
Materials: Galvanized • Cast Iron
Observations:
5.1. Vents appeared serviceable at time of inspection.
6. Chimney Description
Materials: Metal Chimney Unit
Observations:
6.1. Appeared in serviceable condition at the time of the inspection.
7. Gutters / Downspouts
Observations:
7.1. No gutters were noted, so gutter installation is recommended to help ensure proper drainage
away from the foundation.
Pristine 3 Meadow Ct, Champaign, IL
Page 18 of 50
Exterior
1. Exterior Cladding
Materials: Wood
Observations:
1.1. General condition is consistent with age and wear.
2. Fascia
Materials: Wood
Observations:
2.1. Appeared in serviceable condition at the time of the inspection.
3. Soffits, Eaves
Materials: Wood
Observations:
3.1. Appeared in serviceable condition at the time of the inspection.
4. Doorbell
Observations:
4.1. Video type doorbell observed. Functionality of the unit could not be verified, so further
evaluation is recommended to determine if the unit is fully functional.
5. Exterior Electrical
Description: Grounded Outlets (3-prong)
6. Exterior Lighting
Observations:
6.1. The lights were tested and functioned properly.
7. Exterior Faucets
Observations:
7.1. Tested - No deficiencies noted.
Pristine 3 Meadow Ct, Champaign, IL
Page 19 of 50
Garage
1. Location
Detached - Side of the House
Car Spaces: 2
2. Exterior Cladding
Materials: Wood
Observations:
2.1. Soil / siding contact was observed, so grade changes are recommended. Soil or landscape
material should not touch the siding as it can allow excessive moisture transfer into the wall cavity.
Also, it can allow easy and undetected entry of wood destroying insects.
3. Roof Covering
Materials: Composition Shingles
The roof is approximately 15-20 years old.
Observations:
3.1. Gable Style Roof
3.2. Damaged shingles observed. Repairs or replacement shingles are recommended to prevent a
roof leak.
3.3. Missing shingle tabs noted. Repairs are recommended to correct this condition. Failure to
properly replace the missing tabs can result in a roof leak.
4. Roof Framing
Trusses
Observations:
4.1. Roof structure appears functional at this time.
Pristine 3 Meadow Ct, Champaign, IL
Page 20 of 50
5. Garage Doors
Number of Doors: 1
Description: Metal
Observations:
5.1. Damaged metal door panels observed during this inspection. Repairs, or possibly a
replacement door panel appears to be needed at this time.
5.2. Safety cables were not observed running through the middle of the extension type overhead
door springs at this time. I highly recommend the installation of safety cables through the middle
portion of the door springs to contain the springs when they break. Failure to contain these springs
can result in personal injury or property damage.
6. Garage Door Opener Observations
Manufacturer: Stanley
7. Garage Door Safety Features
Safety Sensor: Not Present
8. Ceiling
Materials: Exposed Framing
Observations:
8.1. General conditions of ceilings are consistent with age and wear.
9. Walls
Materials: Exposed Framing
Observations:
9.1. General conditions of walls appeared consistent with age and wear.
10. Exterior Door
Metal
Observations:
10.1. Paint repairs appear to be needed at the trim, brick mold, around the door. Scraping/prep
work should be completed prior to application of the paint. If any soft wood is encountered during
the preparation portion of the paint job, wood repairs/replacement would need to be completed as
well.
10.2. Rust is showing on the metal door. Paint repairs are recommended to ensure the metal is
properly protected.
Pristine 3 Meadow Ct, Champaign, IL
Page 21 of 50
11. Floors
Materials: Concrete
Observations:
11.1. Common cracks were observed, but appears functional at this time.
12. Electrical
Description: Grounded Outlets (3-prong)
Observations:
12.1. Accessible outlets were tested and functional.
12.2. GFCI outlet(s) recommended for installation as a safety upgrade.
13. Lights, Switches
Lighting, Ceiling Fan
Observations:
13.1. Lights operated when tested.
14. Limitations of Garage Components Inspection
Observations:
14.1. Access to some items such as: electric outlets, wall/floor surfaces, and doors was restricted
by storage and personal belongings, any such items are excluded from this inspection report.
Pristine 3 Meadow Ct, Champaign, IL
Page 22 of 50
Electric Service
1. Service Type
Observations:
1.1. Overhead - Mast above the Roof
1.2. No deficiencies noted
2. Service Amps
Service Size: 200, 120/240 Volt
3. Conductor Type Observations
Materials: Plastic Covered • Cloth Covered (Asphalt Impregnated Cotton)
4. Branch Circuit Observations
Materials: Copper • Tin Clad Copper
5. Ground & Bonding
Observations:
5.1. Appears to Extend Down from the Meter Base
Pristine 3 Meadow Ct, Champaign, IL
Page 23 of 50
Electric Panel
1. Location
Locations: Northwest Bedroom Closet
2. Electric Service Panel
Manufacturer: Square D
Observations:
2.1. Panel not completely labeled. All breakers should be labeled as a safety precaution.
3. Max Capacity
Panel Max: 200 Amps
4. Service Wire/Disconnect
Service Wire: Copper
Disconnect Size: 200 Amp Breaker
5. Breakers/Fuses
Breakers or Fuses: Breakers • Number of 120 single pole breakers: 8 • Number of 240 double pole
breakers: 3 • Number of empty slots for future use: 14
Observations:
5.1. 30amp breakers installed (3) for a 120v circuits which is unusual since most circuits are 15 or
20 amp. Further evaluation is recommended and repairs made as needed.
5.2. Breaker is too large for the wire size connected to it. Replace the breaker with a properly sized
unit to correct this potential fire safety hazard.
6. Panel Bonding
Observations:
6.1. Proper bonding observed in the panel.
Pristine 3 Meadow Ct, Champaign, IL
Page 24 of 50
Electric Panel 2
1. Location
Locations: Northwest Bedroom
2. Electric Service Panel
Manufacturer: Square D
3. Max Capacity
Panel Max: 100 Amps
4. Service Wire/Disconnect
Service Wire: Copper
Disconnect Size: Not Present in the Panel
Observations:
4.1. This panel is being fed by the main panel with a 100 amp breaker.
5. Breakers/Fuses
Breakers or Fuses: Breakers • Number of 120 single pole breakers: 8 • Number of 240 double pole
breakers: 2 • Number of empty slots for future use: 0
6. Panel Bonding
Observations:
6.1. Improper bonding observed in the sub-panel box. Neutral buss bars are not supposed to be
bonded to the panel box in a sub-panel. Repairs are recommended to correct this safety hazard.
Pristine 3 Meadow Ct, Champaign, IL
Page 25 of 50
Air Conditioning
1. Location
Location of Unit: North
Type: Central A/C
2. A/C Operation
Observations:
2.1. Unit Operated and is cooling as intended
3. Exterior Unit
Manufacturer: Trane
Observations:
3.1. Deteriorated insulation observed on the refrigerant lines running from the exterior unit to the
house. Repairs/replacement of the insulation is recommended to allow the A/C system to operate
efficiently.
4. Capacity
2.5 Ton
The exterior unit is approximately 15 years old which is beyond it's designed life. Based on the
location, quality of the unit, and other factors, the unit may last longer than the average unit.
5. Area Served
The Entire Home
Differential: 19 Degrees F.
6. Electrical Disconnect
Breaker (No Over Current Protection)
Observations:
6.1. Improper sized breaker noted powering the external condenser unit. The specifications listed
on the manufacturer's ID tag state the max breaker should be 20 amps. The outside disconnect is
a breaker (with no over current protection) and the breaker in the electrical panel is 30 amps.
Repairs are recommended to ensure the outside unit is properly protected.
Pristine 3 Meadow Ct, Champaign, IL
Page 26 of 50
7. Condensate Removal
Condensate Pump
Pristine 3 Meadow Ct, Champaign, IL
Page 27 of 50
Heating System
1. Heating System Operation
Observations:
1.1. Unit operated properly when tested.
2. Heating System
Trane
Observations:
2.1. General condition is consistent with age and wear.
2.2. Improper sized breaker noted powering the furnace. The specifications listed on the
manufacturer's ID tag state the max breaker should be 15 amps. The breaker in the electrical panel
is 20 amps. Repairs are recommended to ensure the unit is properly protected.
3. Type:
Type: Forced Air
Capacity: 80,000 BTU
4. Area Served:
Area Served: Entire Home
The heating system is approximately 15 years old.
5. Fuel
Fuel: Natural Gas
6. Distribution
Materials: Metal Ducts • Insulated Flex Ducts
7. Flue
Materials: Single Wall Into B-Vent
Observations:
7.1. Condensation stains noted coming from the flue joints indicating poor venting of the exhaust
gases. Further evaluation is recommended and repairs made as needed to allow the unit to draft
properly.
Pristine 3 Meadow Ct, Champaign, IL
Page 28 of 50
8. Filter
Location of Filter: Above the furnace
Type & Size: Disposable • Model 2200 - High Efficiency
Observations:
8.1. Broken filter cover door noted. Repairs are recommended.
8.2. Filter is dirty. A replacement filter should be installed as soon as possible.
9. Thermostat Observations
Observations:
9.1. Programmable
Pristine 3 Meadow Ct, Champaign, IL
Page 29 of 50
Plumbing
1. Water Source
Municipal
How Verified: Visual Inspection
2. Service Line
Materials: Copper
Observations:
2.1. Water service line appeared serviceable at time of inspection.
3. Main Water Shutoff
Location: Laundry Area
Observations:
3.1. No deficiencies noted.
4. Water Lines
Materials: Copper
Observations:
4.1. Visible water lines appeared serviceable at time of inspection.
5. Sewage Disposal
Municipal
How Verified: Visual Inspection
6. Drain Pipes
Materials: PVC
Observations:
6.1. Visible drain lines appeared serviceable at time of inspection.
7. Service Caps
Observations:
7.1. Clean out observed and appeared serviceable at time of inspection.
8. Gas Meter
Observations:
8.1. Gas meter/ main shutoff valve is located on the west side of the structure.
9. Gas Service Lines
Materials: Black Iron • Flex Connector
Observations:
9.1. Visible gas lines appeared serviceable at time of inspection.
Pristine 3 Meadow Ct, Champaign, IL
Page 30 of 50
Water Heater
1. Water Heater Operation
Observations:
1.1. Water heater operated properly when tested.
1.2. Temperature of 139 degrees F was measured at a faucet. Turning down the temperature
control on the water heater is recommended since normal water temperature should be 115-125.
Most adults will suffer third-degree burns if exposed to 150 degree water for two seconds. Burns
will also occur with a six-second exposure to 140 degree water or with a thirty second exposure to
130 degree water. Even if the temperature is 120 degrees, a five minute exposure could result in
third-degree burns.
2. Water Heater
Manufacturer: A.O. Smith
3. Fuel:
Fuel: Natural Gas
Capacity: 40 Gal.
4. Area Served:
Area Served: Entire Home
The water heater is approximately 1 year old.
5. Flue
Materials: Single Wall Into B-Vent
6. TPR
Materials: Copper
Observations:
6.1. No deficiencies noted.
Pristine 3 Meadow Ct, Champaign, IL
Page 31 of 50
Interior
1. Ceiling
Materials: Drywall
2. Walls
Materials: Drywall
3. Floors
Materials: Carpet • Laminate
4. Doors
Hollow Wood
5. Closets
Observations:
5.1. Inspected closets appeared functional.
6. Windows
Materials: Vinyl • Wood
7. Electrical
Description: Grounded Outlets (3-prong)
8. Lights, Switches
Materials: Lighting, Ceiling Fan
9. Smoke Detectors
Present: Observed
Observations:
9.1. Test all smoke detectors monthly, replace the battery at least once per year, and install brand
new smoke detectors if they are older than 10 years. Manufacture dates were not checked during
the inspection.
10. Carbon Monoxide Detectors
Observations:
10.1. Test all CO detectors monthly, replace the battery at least once per year, and install brand
new detectors if they are older than 10 years. Some of the new units have a sealed battery that
requires no maintenance for the entire 10 years. Manufacture dates were not checked during the
inspection.
Pristine 3 Meadow Ct, Champaign, IL
Page 32 of 50
11. Limitations of Interior Components Inspection
Observations:
11.1. Access to some items such as: electric outlets, windows, wall/floor surfaces, and cabinet
interiors was restricted by furniture and large quantity of personal belongings, any such items are
excluded from this inspection report.
Pristine 3 Meadow Ct, Champaign, IL
Page 33 of 50
Laundry
1. Locations
Locations: 1st Floor
2. Ceiling
Observations:
2.1. Spot noted in the ceiling with infrared and were tested and verified with my moisture meter.
Further evaluation is recommended and repairs to correct what appears to be a moisture
condition/water leak.
3. Walls
Observations:
3.1. General conditions of the walls are consistent with age and wear.
4. Floors
Observations:
4.1. No deficiencies noted, normal wear and age.
5. Electrical
Description: Grounded Outlets (3-prong)
Observations:
5.1. Missing cover plates noted. All switches and outlet boxes should have covers installed on them
at all times as a safety precaution. If not repaired, a person can come into contact with energized
electrical components.
6. Lights, Switches
Observations:
6.1. Lights operated when tested.
7. HVAC Source
Observations:
7.1. Not Present.
Pristine 3 Meadow Ct, Champaign, IL
Page 34 of 50
8. Washer Hose Bib
Observations:
8.1. Observed only, not tested. Appears serviceable at the time of the inspection.
9. Washer Drain
Observations:
9.1. Drains to Stand Pipe
9.2. Observed only, not tested. Appears serviceable at the time of the inspection.
10. Dryer Hookup
Observations:
10.1. Electric Hookup observed
11. Dryer Vent
Materials: Corrugated Metal Flex • Rigid Metal
Observations:
11.1. Dryer vent appeared serviceable at time of inspection.
Pristine 3 Meadow Ct, Champaign, IL
Page 35 of 50
Kitchen
1. Cooking Appliance
Materials: Electric Range
Observations:
1.1. The heating elements/burners and oven operated when tested. This does not confirm the
efficiency of the system.
2. Stove Hookup
Observations:
2.1. Electric Hookup
3. Ventilator
Observations:
3.1. Tested - Fan vents to the exterior of the house.
4. Refrigerator
Observations:
4.1. Refrigerator was operational at the time of the inspection.
5. Microwave
Observations:
5.1. The microwave was operated and functioned as intended at the time of the inspection.
6. Sink/Basin
Stainless Steel
Observations:
6.1. Operated when tested. No deficiencies noted.
7. Disposal
Observations:
7.1. The garbage disposal was tested and was functional at the time of the inspection.
8. Electrical
Description: GFCI Outlets • Grounded Outlets (GFCI Protected)
Observations:
8.1. GFCI protected outlets present with an open ground condition. That means the outlet is GFCI
protected but it does not have an equipment ground. Upgrading the outlet to include an equipment
ground is recommended if it is used to power certain devices such as a computer or newer style
television that require a ground.
9. Lights, Switches
Observations:
9.1. Lights operated when tested.
10. Counter Tops
Materials: Granite or Quartz
Observations:
10.1. The counter tops are in acceptable condition with normal wear for age.
11. Cabinets
Observations:
11.1. Wood & Composite Materials
11.2. The cabinets were in acceptable condition.
Pristine 3 Meadow Ct, Champaign, IL
Page 36 of 50
12. Ceiling
Observations:
12.1. General conditions of ceilings are consistent with age and wear.
13. Walls
Observations:
13.1. General conditions of the walls are consistent with age and wear.
14. Floors
Observations:
14.1. Loose seams noted on the vinyl flooring. This is a trip hazard, so repairs are recommended.
15. HVAC Source
Observations:
15.1. Heating source is working at the time of the inspection.
Pristine 3 Meadow Ct, Champaign, IL
Page 37 of 50
Bathroom
1. Locations
Locations: South
2. Ceiling
Observations:
2.1. General conditions of ceilings are consistent with age and wear.
3. Walls
Observations:
3.1. General conditions of the walls are consistent with age and wear.
4. Floors
Observations:
4.1. No deficiencies noted, normal wear and age.
5. Doors
Observations:
5.1. Tested doors appeared functional at the time of the inspection.
6. Electrical
Description: GFCI Outlet
Observations:
6.1. GFCI outlet present with an open ground condition. That means the outlet is GFCI protected
but it does not have an equipment ground. Upgrading the outlet to include an equipment ground is
recommended if it is used to power certain devices such as a computer or newer style television
that require a ground.
7. Lights, Switches
Observations:
7.1. Missing light cover noted. A replacement light cover is recommended.
8. Sink/Basin
Ceramic
Observations:
8.1. Operated when tested. No deficiencies noted.
9. Toilet
Observations:
9.1. Operated when tested. No deficiencies noted.
10. Tub & Tub/Shower
Materials: Built-In Tub w/ Surround
Observations:
10.1. Shower diverter does not properly route all of the water flow up to the shower head. A
replacement tub spout/diverter valve unit appears to be needed.
Pristine 3 Meadow Ct, Champaign, IL
Page 38 of 50
11. HVAC Source
Observations:
11.1. Heating source is working at the time of the inspection.
12. Ventilation
Observations:
12.1. Electric Unit
12.2. Unit functioned when tested.
Pristine 3 Meadow Ct, Champaign, IL
Page 39 of 50
North Bathroom
1. Locations
Locations: Half
2. Ceiling
Observations:
2.1. Spot noted in the ceiling with infrared and were tested and verified with my moisture meter.
Further evaluation is recommended and repairs to correct what appears to be a moisture
condition/water leak.
3. Walls
Observations:
3.1. Spot noted in the wall with infrared and were tested and verified with my moisture meter.
Further evaluation is recommended and repairs to correct the moisture condition/water leak.
4. Floors
Observations:
4.1. No deficiencies noted, normal wear and age.
5. Doors
Observations:
5.1. Missing door was observed. Door installation is recommended.
Pristine 3 Meadow Ct, Champaign, IL
Page 40 of 50
6. Electrical
Description: GFCI Outlet
Observations:
6.1. GFCI protected outlets present with an open ground condition. That means the outlet is GFCI
protected but it does not have an equipment ground. Upgrading the outlet to include an equipment
ground is recommended if it is used to power certain devices such as a computer or newer style
television that require a ground.
7. Lights, Switches
Observations:
7.1. Lights operated when tested.
8. Sink/Basin
Ceramic
Observations:
8.1. Operated when tested. No deficiencies noted.
9. Toilet
Observations:
9.1. Operated when tested. No deficiencies noted.
10. HVAC Source
Observations:
10.1. Heating source is working at the time of the inspection.
Pristine 3 Meadow Ct, Champaign, IL
Page 41 of 50
Bedrooms
1. Locations
Locations: Northwest
2. Ceiling
Observations:
2.1. General conditions of ceilings are consistent with age and wear.
3. Walls
Observations:
3.1. General conditions of the walls are consistent with age and wear.
4. Floors
Observations:
4.1. No deficiencies noted, normal wear and age.
5. Doors
Observations:
5.1. Paint repairs appear to be needed at the trim, brick mold, around the (exterior door).
Scraping/prep work should be completed prior to application of the paint. If any soft wood is
encountered during the preparation portion of the paint job, wood repairs/replacement would need
to be completed as well.
6. Windows
Observations:
6.1. Bottom sash falls down when released and will not stay open on the west window. Repairs are
recommended to allow the window to function properly.
7. Closets
Observations:
7.1. Inspected closets appeared functional.
Pristine 3 Meadow Ct, Champaign, IL
Page 42 of 50
8. Electrical
Grounded Outlets (3-prong)
Observations:
8.1. Open grounds noted at the 3 prong outlets. Any 3-prong outlet installed in a house is supposed
to be properly grounded. Repairs are recommended to correct this condition.
9. Lights, Switches
Observations:
9.1. Lights operated when tested.
9.2. Missing light covers noted.
10. HVAC Source
Observations:
10.1. Not Present.
Pristine 3 Meadow Ct, Champaign, IL
Page 43 of 50
Bedroom 2
1. Locations
Locations: Northeast
2. Ceiling
Observations:
2.1. General conditions of ceilings are consistent with age and wear.
3. Walls
Observations:
3.1. General conditions of the walls are consistent with age and wear.
4. Floors
Observations:
4.1. No deficiencies noted, normal wear and age.
5. Doors
Observations:
5.1. Tested door appeared functional at the time of the inspection.
6. Windows
Observations:
6.1. All windows were tested and operated normally.
7. Closets
Observations:
7.1. Inspected closets appeared functional.
8. Electrical
Description: Grounded Outlets (3-prong)
Observations:
8.1. Open grounds noted at the 3 prong outlets. Any 3-prong outlet installed in a house is supposed
to be properly grounded. Repairs are recommended to correct this condition.
9. Lights, Switches
Observations:
9.1. Lights and fan operated when tested.
10. HVAC Source
Observations:
10.1. Heating source is working at the time of the inspection.
Pristine 3 Meadow Ct, Champaign, IL
Page 44 of 50
Bedroom 3
1. Locations
Locations: Southeast
2. Ceiling
Observations:
2.1. General conditions of ceilings are consistent with age and wear.
3. Walls
Observations:
3.1. General conditions of the walls are consistent with age and wear.
4. Floors
Observations:
4.1. No deficiencies noted, normal wear and age.
5. Doors
Observations:
5.1. Hollow wood closet door has a hole. This type of door is almost impossible to satisfactorily
patch, so a replacement door appears to be needed.
6. Windows
Observations:
6.1. All windows were tested and operated normally.
7. Closets
Observations:
7.1. Inspected closets appeared functional.
8. Electrical
Description: Grounded Outlets (3-prong)
Observations:
8.1. Open grounds noted at the 3 prong outlets. Any 3-prong outlet installed in a house is supposed
to be properly grounded. Repairs are recommended to correct this condition.
Pristine 3 Meadow Ct, Champaign, IL
Page 45 of 50
9. Lights, Switches
Observations:
9.1. Lights an Fan operated when tested.
10. HVAC Source
Observations:
10.1. Heating source is working at the time of the inspection.
Pristine 3 Meadow Ct, Champaign, IL
Page 46 of 50
Bedroom 4
1. Locations
Locations: South
2. Ceiling
Observations:
2.1. General conditions of ceilings are consistent with age and wear.
3. Walls
Observations:
3.1. General conditions of the walls are consistent with age and wear.
4. Floors
Observations:
4.1. No deficiencies noted, normal wear and age.
5. Doors
Observations:
5.1. Tested doors appeared functional at the time of the inspection.
6. Windows
Observations:
6.1. All windows were tested and operated normally.
7. Closets
Observations:
7.1. Inspected closets appeared functional.
8. Electrical
Description: Grounded Outlets (3-prong)
Observations:
8.1. Open grounds noted at the 3 prong outlets. Any 3-prong outlet installed in a house is supposed
to be properly grounded. Repairs are recommended to correct this condition.
9. Lights, Switches
Observations:
9.1. Lights operated when tested.
10. HVAC Source
Observations:
10.1. Heating source is working at the time of the inspection.
Pristine 3 Meadow Ct, Champaign, IL
Page 47 of 50
Areas
1. Locations
Locations: Hallway • Living / Dining Room
2. Ceiling
Observations:
2.1. General conditions of ceilings are consistent with age and wear.
3. Walls
Observations:
3.1. General conditions of the walls are consistent with age and wear.
4. Floors
Observations:
4.1. No deficiencies noted, normal wear and age.
5. Doors
Observations:
5.1. Tested doors appeared functional at the time of the inspection.
6. Windows
Observations:
6.1. All accessible windows were tested and operated properly.
7. Closets
Observations:
7.1. Inspected closets appeared functional.
8. Electrical
Description: Grounded Outlets (3-prong)
Observations:
8.1. Accessible outlets were tested and functional.
9. Lights, Switches
Observations:
9.1. Lights and fan operated when tested.
10. HVAC Source
Observations:
10.1. Heating source is working at the time of the inspection.
Pristine 3 Meadow Ct, Champaign, IL
Page 48 of 50
Fireplace/Wood Stove
1. Fireplace / Stove
Free Standing - Wood Burning Stove
Observations:
1.1. General condition is consistent with age and use.
1.2. Cracked hearth material noted. Repairs are recommended.
2. Flue
Type: Metal Piping
% Inspected: 0% inspected due to the type of fireplace/stove.
Pristine 3 Meadow Ct, Champaign, IL
Page 49 of 50
Structural Components
1. Structure
Observations:
1.1. Wood Frame
1.2. No visible deficiencies noted.
2. Foundation Observations
Materials: Poured Concrete
Observations:
2.1. Crack noted on the wall which is 1/8" wide (south side). Further evaluation is recommended by
a qualified concrete person and proper repairs made if needed.
3. Bearing Walls
Materials: Wood Framed
4. Radon Mitigation
Materials: Not Present
Pristine 3 Meadow Ct, Champaign, IL
Page 50 of 50
Glossary
Glossary
Term Definition
A/C Abbreviation for air conditioner and air conditioning
GFCI A special device that is intended for the protection of personnel
by de-energizing a circuit, capable of opening the circuit when
even a small amount of current is flowing through the grounding
system.
PVC Polyvinyl chloride, which is used in the manufacture of white
plastic pipe typically used for water supply lines.
CHECKED
Do you have receipts for repairs performed?
Have you checked items not tested or checked during the home inspection?
Ex: furniture or storage preventing testing doors, windows, outlets
or temperature prevented testing the A/C unit
Check for items purchased with the house:
Drapes
Appliances
Play structures
Remote controls: ceiling fans, garage doors, automatic window blinds
Check Mechanicals and Plumbing:
Furnace - Is it heating? Do you have heat in all rooms?
A/C - Is it cooling? (don't test if it is below 65 F)
Water heater - Do you have hot water?
Check water at all sinks, tubs, showers, exterior and garage hose faucets
Do the jets work on the spa tub?
Toilets flush?
Leaks under sinks?
Washer, Dryer, Dishwasher, Stove, Microwave, Refrigerator
Miscellaneous Items:
Lights
Windows
Doors - interior and doors to the outside
Garage door openers
Smoke Detectors
CO detectors
Doorbell
Note: Mold can begin growing within 48 hours and water damage can occur at any time.
So, even if your inspector did not find signs of mold or water damage, you should look for
these during the final walk-through.
Pristine Inspections & Testing - FINAL WALK-THROUGH CHECKLIST
The final walk-through gives homebuyers an opportunity to inspect the property before closing
on the sale of the property. During the walk-through, buyers can determine if the repair work
they requested in the agreement has been completed. They can also confirm that the condition
of the property has not changed or deteriorated since the inspection or the last time it was seen.
Because the walk-through takes place only a few days or even hours before closing, it is easy for
excited homebuyers to skip taking another careful look at the property. However, being
thorough during these final steps can save you from unexpected headaches and expenses.
Bring this checklist to the walk-through to keep you on track and be sure to address any issues
before closing. This is your final opportunity to verify that things are working as expected and to
test items that may not have been able to be tested due to conditions at that time.
Pristine Inspections and Testing, Inc. 217-352-3743 PristineHI.com
Pristine Inspections & Testing, Inc.
Inspection Agreement
This is a legally binding contract and contains an arbitration clause.
Please read it carefully.
Property Address:
Inspection Fee $
Client(s):
This inspection agreement contains the terms and conditions of CLIENT’s (named above) contract with the inspection company, herein referred to as INSPECTOR, for an inspection of the property stated
above. The inspection agreement contains limitations on the scope of the inspection, remedies and liability. By signing below, CLIENT represents and warrants that all necessary approvals have been secured
for the INSPECTOR to perform the inspection of the property. CLIENT also warrants that they will carefully read the entire inspection or inspection report.
Inspection
The INSPECTOR agrees to perform a limited visual inspection and an inspection report of the systems and
components included in the inspection as they exist at the time of inspection and for which the CLIENT agrees
to pay a fee. The inspection will be performed in accordance with the standards of practice of the American
Society of Home Inspectors, and is limited by the limitations, exceptions and exclusions so stated in the
standards of practice and this agreement. Copies of these standards will be provided upon request.
This inspection is limited to a visual examination of the exposed and readily accessible areas of the building, and
to this extent includes an evaluation of the following major components:
Foundation
Electrical
Exterior Walls
Doors
Sub-floor Framing
Plumbing
Roofing
Ceilings
Windows
Site Drainage
Heating
A/C
Floors
Venting
Built-in Appliances
Water heaters
Fireplaces
Stairs
Chimneys
Attic
If near building: Paving, Decks
Limitations, Exception and Exclusions
The inspection only includes the systems and components expressly and specifically identified in the inspection
report. In addition, any area which is not exposed to view, is concealed, is inaccessible because of soil, walls,
floors, carpet, ceilings, furnishings or other fashion is excluded. The inspection does not include any destructive
testing or the dismantling or moving of any objects or portion of the premises. The following systems and
components and areas are among those NOT included in the inspection or inspection report.
Latent or concealed defects, compliance with zoning or ordinances or permit research or system or component recalls.
Structural, geological, soil, wave, action or hydrological stability, survey, engineering, analysis, or testing.
Obtaining or reviewing information from any third party.
Termites or other wood destroying insects and organisms, rodents or other pests, dry rot or fungus; or other
damage relating to the preceding.
Private water, sewer systems (unless otherwise listed as an additional service) or related equipment, such as
wells, septic systems, sewage pumps, water softeners or purifiers, radiant heat systems or solar heating systems.
Low voltage electrical systems, such as TV antenna, TV signal cables, cable TV systems, telephones,
intercoms, speaker wires, automated equipment, and landscape lighting.
Pools, spas, hot tubs, saunas, steam baths, ponds, fountains or other types of related systems or components.
Window-mount or wall-mount air conditioners or gas-powered air conditioners.
Building or property measurements, building value appraisal and repair cost estimates.
Unique/technically complex systems or components such as furnace heat exchangers, air quality control
systems, satellite systems, lawn sprinkler systems, thermostatic or time clock controls, radio controlled devices,
remote controls, motion sensing or photoelectric devices, automatic timer controls, automatic gates or elevators,
lifts, dumbwaiters, central vacuum systems, trash compactors.
Free standing appliances and gas appliances such as fire pits, barbecues, heaters, lamps, and refrigerator ice
makers and water dispensers.
Electrical load calculations; testing of gas shut off valves; testing for gas leaks.
Seismic safety, security or fire safety systems, fire sprinklers, alarm systems or security bars and/or safety
equipment.
Any adverse conditions that may affect desirability of the property including but not limited to proximity to
railroad tracks or air routes, boundaries, easements or rights of way, adjoining properties or neighborhood.
Radon gas, water or air quality (unless otherwise listed as an additional service), asbestos, chinese drywall,
lead paint, urea formaldehyde, toxic or flammable chemicals, PCB’s or other toxins, electromagnetic fields,
underground storage tanks, proximity to toxic waste sites or other environmental or health hazards.
Decay of the interior of logs in
log homes, log structures, walls or foundations, or similar defects.
Advisability of purchase; adequacy, efficiency, durability or quality of any system or component.
Cosmetic finishes and conditions; landscaping and foliage.
Noise transmission; determination of odors.
Evaluating fire-resistive qualities of any system, structure or component of the building.
Items specifically noted as excluded or items not specifically identified in report.
Thermal observations are not guaranteed, expressed or limited, or conclusive evidence of the presence or lack
thereof of insulation, moisture, air leakage, or other anomalies.
Technically exhaustive inspections, evaluations or tests of any type.
Systems, structures or components which are not permanently installed including detached ancillary buildings
(except for parking structures).
Requirements of the Americans with Disabilities Act (A.D.A.).
Disputes and Statute of Limitations
CLIENT agrees that any claim (for negligence, breach of contract or otherwise), be made in writing and reported
to INSPECTOR within ten (10) days of the discovery. CLIENT further agrees to allow INSPECTOR the
opportunity to re-inspect the claimed discrepancy before CLIENT (or CLIENT’s agents, employees or
independent contractors) repairs, replaces, alters or modifies the claimed discrepancy. CLIENT understands
and agrees that any failure to notify INSPECTOR as stated above shall constitute a waiver of any and all claims
CLIENT may have against INSPECTOR. CLIENT agrees that no action may be brought to recover damages
against INSPECTOR or its agents or employees more than one year from the date of the inspection. Failure to
bring said action within one year of the date of the inspection is a complete waiver of any rights, actions or
causes of action that may have arisen therefrom. Time is expressly of the essence herein. This time period may
be shorter than otherwise provided by law.
INITIALS
Limitation of Liability
In the event INSPECTOR fails to fulfill the obligations under this agreement, CLIENT’s exclusive remedy at law
or inequity against INSPECTOR is limited to the inspection fee. CLIENT acknowledges that this limitation of
liability is reasonable in view of the relatively small fee that INSPECTOR charges for performing the inspection
when compared with the large potential of exposure that INSPECTOR might otherwise incur in the absence of
such limitation of liability.
INITIALS
Non Expert Visual Inspection
CLIENT understands and agrees that INSPECTOR is knowledgeable in a variety of areas, but is not to be
considered as an expert in any field unless otherwise specified. The inspection and report are to be considered
an unbiased view, based on the experience of INSPECTOR. The report identifies only general conditions
affecting the property. If recommendations are made that CLIENT should consult an expert for further evaluation
or repairs, it is the CLIENT’s responsibility, at CLIENT’s expense, to contact and obtain further inspections or
evaluations with experts who shall be selected by CLIENT. If CLIENT fails to consult specialized experts as
recommended by INSPECTOR, the INSPECTOR shall be absolved of any and all liability.
Confidentiality of Report
The inspection and report are for the use of CLIENT only, who gives INSPECTOR permission to discuss
observations with real estate agents, owners, repair persons, and other interested parties. INSPECTOR shall
be the sole owner of the report and all rights to it. INSPECTOR accepts no responsibility for use or
misinterpretation by third parties, and third parties who rely on it in any way do so at their own risk and release
INSPECTOR (including employees and business entities) from any liability whatsoever. INSPECTOR’S
inspection of the property and the report are in no way a guarantee or warranty, express or implied, regarding
the future use, operability, habitability or suitability of the home/building or its components. All warranties,
express or implied, including warranties of merchantability and fitness for a particular purpose, are expressly
excluded to the fullest extent allowed by law. No determination of insurability will be made.
Payment and Receipt of Report
Payment is due upon completion of the inspection by INSPECTOR. If CLIENT is not present at the inspection,
payment shall be due upon receipt of the report. Acceptance of the inspection report shall constitute agreement
with all the terms of this contract, regardless of whether this contract is signed by the CLIENT. If CLIENT objects
to any of the terms of this agreement, CLIENT shall return the written inspection report and all copies to the
INSPECTOR within three days and any fee that has been paid will be refunded to the CLIENT. Failure to return
the written inspection report and payment of the fee shall constitute the full acceptance of all of the terms of this
agreement by the CLIENT. In the event CLIENT fails to pay any amount due hereunder and it becomes
necessary for the INSPECTOR to take action in a court of law to collect such sums, CLIENT shall be responsible
for all costs and reasonable attorney’s fees incurred by the INSPECTOR. CLIENT shall not rely on any oral
statements made by INSPECTOR prior to the issuance of the written report.
Other Services
INSPECTOR may have an affiliation with a third party service provider (”TPSP”) in order to offer CLIENT
additional value-added services. By entering into this agreement CLIENT (a) authorizes INSPECTOR to provide
CLIENT contact information (including telephone number) to the TPSP, (b) waive and release any restrictions
that may prevent the TPSP from contacting CLIENT (including by telephone), and (c) authorize the TPSP to
contact CLIENT (including by telephone) regarding special home alarm system offers.
It is understood and
agreed to by the parties hereto that all the provisions, limitations, exceptions, and exclusions of this agreement
shall apply to any optional services entered into by the parties.
Entire Agreement, Modifications and Third Parties
This agreement represents the entire agreement between the parties. No oral agreements, understandings or
representations shall change, modify or amend any part of this agreement. No change or modification shall be
enforceable against any party unless such change or modification is in writing and signed by the parties and
supported by valid consideration. This agreement shall be binding upon inure to the parties hereto and their
spouses, heirs, executors, administrators, successors, assigns and representatives of any kind whatsoever.
Governing Law and Severability
This agreement shall be governed by law. If any portion of this contract is found to be invalid or unenforceable
by any court or arbitration, the remaining terms shall remain in force between the parties.
I have read, understand and agree to all of the above terms and conditions of this agreement.
Signature of Client: Date:
E-mail to: Client Agent INITIALS:
Client E-mail:
Agent Name or E-mail:
Inspector: Date:
Report #: CASH VISA MC DISC CHECK#
PristineHI.com
217-352-3743
Fax: 217-402-9851
3905 Farhills Dr.
Champaign, IL 61822
IL ENTITY Lic. # 451000932
IL Lic. #4500