Governor overspeed
switch:
Front door (2000 or later) (Code zone)
closing speed: sec
Rear door (2000 or later) (Code zone)
closing speed: sec
8.6.4.19.2 Safeties type (no load) A B C
8.6.4.19.4 Slack-rope devices and stop motion on winding drum machines
8.6.4.19.5 Normal and final terminal stopping devices
8.6.4.19.6 Firefighters’ emergency operation
8.6.4.19.7 Standby or emergency power operation (no load)
8.6.4.19.8 Power operation of door system: Door closing speed (Code zone): Front sec; Rear sec;
Door closing force: Front lbf; Rear lbf
8.6.4.19.9 Broken rope, tape or chain switch
8.6.4.19.10 Functional safety of SIL rated devices
8.6.4.19.11 Ascending car overspeed protection and unintended car motion devices
8.6.4.19.12 Traction loss detection means
8.6.4.19.13 Broken-suspension member and residual strength detection means
8.6.4.19.14 Occupant evacuation operation
8.6.4.19.15 Emergency communications
8.6.4.19.16 Means to restrict hoistway or car door opening
Miscellaneous concerns – list on page 2
Category 5 – Must complete Category 1 with this section
8.6.4.20.1 Car: Gov jaw trip: fpm; Gov overspeed switch: fpm; Gov Safety slide distance: in;
Safety release carrier pull force: lbf; Gov pull through force: lbf
Counterweight: Gov jaw trip: fpm; Gov overspeed switch: fpm; Safety slide distance: in;
Safety release carrier pull force: lbf; Gov pull through force: lbf
8.6.4.20.4 Driving machine brakes (apply a seal and tag)
8.6.4.20.6 Emergency terminal stopping and speed-limiting devices
8.6.4.20.7 Power opening of doors
8.6.4.20.8 Leveling zone and leveling speed
8.6.4.20.9 Inner landing zone
8.6.4.20.10 Braking system, traction and traction limits
8.6.4.20.11 Emergency brake
The tests were performed in compliance with ASME 17.1, A117.1, and Iowa Code 89A and in accordance with the code in effect at time of the original
installation and/or any applicable alteration(s). Complete page 2 for each failed item.
(check all that apply)
Type: Passenger Freight LULA Restricted SPPE MRL
Periodic Traction Elevator Test
Elevator Safety
150 Des Moines Street
Des Moines, IA 50309
Phone: 515-725-5612/515-725-5608
Fax: 515-242-5076
elevators@iwd.iowa.gov
www.iowaelevators.gov
Check one:
. Annual 5 Year
Last category 1
test date:
Last category 5
test date:
Company Performing Test Company Address, City, State, Zip Date
Individual Performing Test Signature Witness (if required) QEI#
click to sign
signature
click to edit