SPECIFICATION SUBMITTAL Page
Job Name:
Job Number:
Model Numbers:
EcoSystem® CC-4BRL 4-Button Wallstation
369407a 1 09.19.11
4-Button Wall Control with Raise/Lower
The 4-Button Wallstation recalls lighting presets for
a group of EcoSystem
® devices. The wallstation
connects directly to the EcoSystemR ballast, ballast
module, Energi Savr Node
TM, or QS Sensor Module
(QSM) via low-voltage wiring.
Features
• Wires Class 2 / Low-Voltage
• Mounts easily in any single-gang wallbox
• 4 Presets as well as All On and All Off
• Raise/Lower rocker controls all assigned ballasts
Built-in infrared receiver allows wallstation to be used
as a programming point for EcoSystemR ballasts or
ballast modules (traditional programming via PDA only)
• Infrared (IR) signals are received through the plastic
button (maximum distance of 10 ft / 3 m)
• Programming of control groups can be performed at
the wallstation
Programming of scene levels can be performed at the
wallstation when used only with EcoSystem
® ballasts
or ballast modules
• Multi-color LED to indicate button presses,
programming mode, and reception of infrared signals
• Green LEDs shall be on at all times and operate as a
“night light”
• Red LEDs shall indicate programming mode is active
• Fits any designer (Claro
®) opening faceplates
• Faceplate not included
• Zone Control when used with Energi Savr Node
TM or
Quantum
®
Notes
• Zone toggle and unaffected zone not supported in this
model
• This product is designed to control a single ballast or
group of ballasts or modules
• A second 4B control in the same group will perform
the same function (recalls the same 4 scenes)
1
®
SPECIFICATION SUBMITTAL Page
Job Name:
Job Number:
Model Numbers:
EcoSystem® CC-4BRL 4-Button Wallstation
369407a 2 09.19.11
Power
• Operating Voltage: Low-voltage Class 2, 20 V-
• Output Signal: 0–20 V
-
• Current Draw: 25 mA maximum
Environment
• Temperature: 32 to 104 °F (0 to 40 °C)
• Relative humidity: less than 90% non-condensing
Dimensions
• Including ClaroR wallplate (sold separately)
Specifications
Standards
• UL Listed to US and Canadian safety standards
• cUL Listed
• Designed for Class 2 operation only. Voltages do
not exceed 35 V-. Complies with requirements of
NFPA 70, of the National Electric Code (NECR)
• Follow all applicable national and/or local wiring
regulations when installing this wallstation
• For use with EcoSystem
® products, Energi Savr
Node
TM and Quantum®
Mechanical
Gloss nish available in White, Black, Light
Almond, and Ivory
• Green LED night light, red LED for programming
Notes
• Total wire length from keypad to device must not
exceed 100 ft (30 m)
• Lead wires for connection to device
Wiring
Wiring to EcoSystemR Ballast, Ballast
Module, Energi Savr NodeTM or
QS Sensor Module (QSM)
• Wire color designations:
Red = 20 V
-
Black = Common
White = Signal (IR terminal on ballast or
module)
Make sure that the supply breaker for the
EcoSystemR device to which the control
will be connected is OFF
Connect the three conductors to the
appropriate terminals of the EcoSystemR,
ballast, ballast module, Energi Savr Node
TM
or QS Sensor Module (QSM)
2.5 in
(64 mm)
4.69 in
(119 mm)
2.94 in
(75 mm)
1.45 in
(37 mm)
Profile
Front
White
Red
Black
2