APPLICATION FOR STANDARD PLAN APPROVAL
DEMOLITION
Applicability Criteria
1. Land disturbance is for demolition and removal of a structure, building foundation, building slab, roadway, driveway,
parking lot, sidewalk, or other amenity resulting in exposed soil, including access and staging for demolition activities.
2. Total disturbance is 5.0 acres or less, and no greater than 1.0 acre will be disturbed at any time throughout the course of
construction.
3. Disturbed land will be restored to a stabilized surface. No additional impervious surfaces shall be created as part of the
demolition project.
Site Information
Site Location including previous Approved Sediment and Stormwater Plan Name, if applicable:
Previous Plan Approval Number:
Tax Parcel ID:
Parcel Total Acres (nearest 0.1ac):
Disturbed Acres (nearest 0.1ac):
Proposed Impervious Area (square feet):
Wooded area to be cleared:
Applicant Information
Owner:
Mailing Address:
Owner Phone:
Owner Email:_______________________________________
Applicant:
Mailing Address:
Applicant Phone:
Applicant Email:_____________________________________
Fees
The review fee is $165 per disturbed acre to the nearest 0.1 acre with a minimum fee of $165 for any standard plan approvals
disturbing less than 1.0 acre. Make checks payable to City of Newark.
Approval Information (for office use only)
Approval # Fee Paid: $
Approved by: Approval Date:
Title: Expiration Date:
PWWR SWM Std Plan App - Demolition [May 2020].pdf
1 of 2
Last Revised: May 2020
Standard Conditions
1. Construction site stormwater management best management practices will be used. Standard Detail and Specification DE-
ESC-3.7.1 ESC For Minor Development will be followed (see attachment).
2. Construction projects exceeding 1.0 acre of total disturbance require submittal of a Notice of Intent (NOI) for Stormwater
Discharges Associated with Construction Activity. A plan fulfilling Stormwater Pollution Prevention Plan (SWPPP)
requirements must be developed to obtain general permit coverage for Stormwater Discharges Associated with
Construction Activity (see attachment).
3. Approval of this Standard Plan does not relieve the applicant from complying with any and all federal, state, county or
municipal laws and regulations.
Stabilization Conditions
1. Following initial soil disturbance or redisturbance, temporary or permanent stabilization with seed and mulch shall be
completed within 14 calendar days to the surface of all disturbed areas not actively under construction.
2. Specific stabilization recommendations may be found in the Delaware Erosion and Sediment Control Handbook, 3.4.3
Standard and Specifications for Vegetative Stabilization.
Applicant Certification
I, the undersigned, certify that the information supplied on this Application for Standard Plan Approval is accurate, the
proposed land disturbing activity meets the criteria established, and all conditions of this Standard Plan Approval will be met by
the applicant, contractor, and owner during construction and post construction.
Applicant Signature: Date:
Applicant Printed Name: Title:
***THIS STANDARD PLAN APPLICATION FORM MUST BE MAINTAINED ON THE SITE AT ALL TIMES DURING CONSTRUCTION***
PWWR SWM Std Plan App - Demolition [May 2020].pdf
2 of 2
Last Revised: May 2020
click to sign
signature
click to edit
Source: Symbol: Detail No.
Standard Detail & Specifications
ESC for Minor Development
DE-ESC-3.7.1
Sheet 1 of 2
Adapted from IN DNR,
"Erosion Control for the
Home Builder"
LEGENDLEGEND
LEGENDLEGEND
LEGEND
Flow Inlet protection - Type 1
Silt Fence SF
Sensitive Area Protection SAP
Stabilized Construction Inlet Protection - Type 2
Entrance SCE
Proposed Structure
Stockpile
IP-1
IP-2
SCE
SAP
SAP
SFSF
SF
SF
SF SF
SF
IP-1
IP-2
t
s
s
t
t
t
Downspout
Extender
(Typ.)
Property Line (Typ.)
Effective February 2019
Source: Symbol: Detail No.
Standard Detail & Specifications
ESC for Minor Development
Construction Notes:
1. Evaluate the Site.
a. Identify Vegetation To Be Saved
b. Protect Trees and Sensitive Areas
2. Install Perimeter Erosion And Sediment Controls.
a. Protect down-slope areas with vegetative filter strips.
b. Protect down-slope areas with silt fence.
c. Restrict all lot access to stabilized construction entrance to prevent vehicles from tracking
mud onto roadways.
d.
Install inlet protection on nearby storm drain inlets.
3. Prepare the Site for Construction.
4. Salvage and Stockpile the Topsoil/Subsoil
5. Build the Structure(s) and Install the Utilities.
6. Install Downspout Extenders
7. Maintain the Control Practices.
a. Maintain all erosion and sediment control practices until construction is completed and
the lot is stabilized.
b. Inspect the control practices a minimum of twice a week and after each storm event,
making any needed repairs immediately.
8. Revegetate the Building Site.
a.
Redistribute the stockpiled subsoil and topsoil.
b. Seed or sod bare areas.
c. Mulch newly seeded areas.
9. Remove Remaining Temporary Control Measures.
DE-ESC-3.7.1
Sheet 2 of 2
Adapted from IN DNR,
"Erosion Control for the
Home Builder"
Effective February 2019
Source: Symbol: Detail No.
Standard Detail & Specifications
Construction Site Waste Mgt &
Spill Control
DE-ESC-3.6.1
Sheet 1 of 5
Delaware ESC Handbook
DATA TO BE PROVIDED
Volume of Potential
Pollution
Height of containment
Area of containment
Volume of containment
Min. 9" compost
log or DE# 3
Stone berm
H
Fuel Tank
Spill
containment
Area
Fuel Tank
Stake as required per
compost log
manufacturer guidelines
Double layer
plastic sheeting
Double layer plastic
sheeting, or
approved equal
Effective February 2019
Source: Symbol: Detail No.
Standard Detail & Specifications
Construction Site Waste Mgt &
Spill Control
Pollution Prevention – Spill Prevention
1. Fueling should only take place in signed designated areas, away from downstream drainage
facilities and watercourses.
2. Fueling must be with nozzles equipped with automatic shut-off to control drips. Do not top off.
3. Protect the areas where equipment or vehicles are being repaired, maintained, fueled or parked
from storm water run-on and runoff.
4. Use barriers such as berms to prevent storm water run-on and runoff, and to contain spills.
5. Place a “Fueling Area” sign next to each fueling area.
6. Store hazardous materials such as fuel, solvents, oil and chemicals in secondary containment.
7. Inspect vehicles and equipment for leaks on each day of use. Repair fluid and oil leaks
immediately.
8. Absorbent spill clean-up materials and spill kits must be available in fueling areas and on fuel
trucks.
9. If fueling is to take place at night, make sure the fueling area is sufficiently illuminated.
10. Properly dispose of used oil, fluids, lubricants and spill clean-up materials.
CLEAN UP SPILLS
1. If it is safe to do so, immediately contain and clean up any chemical and/or hazardous material
spills.
2. Properly dispose of used oil, fluids, lubricants and spill clean-up materials.
3. Do not bury spills or wash them down with water.
LEAKS AND DRIPS
1. Use drip pans or absorbent pads at all times. Place under and around leaky equipment.
2. Do not allow oil, grease, fuel or chemicals to drip onto the ground.
3. Have spill kits and clean up material on-site.
4. Repair leaky equipment promptly or remove problem vehicles and equipment from the site.
Clean up contaminated soil immediately.
5. Store contaminated waste in sealed containers constructed of suitable material. Label these
containers properly.
6. Clean up all spills and leaks. Promptly dispose of waste and spent clean up materials.
DE-ESC-3.6.1
Sheet 2 of 5
Delaware ESC Handbook
Effective February 2019
Source: Symbol: Detail No.
Standard Detail & Specifications
Construction Site Waste Mgt &
Spill Control
DE-ESC-3.6.1
Sheet 3 of 5
Adapted from USEPA
Pub. 840-B-92-002
Notes:
The Construction Site Pollution Prevention Plan should include the following elements:
1. Material Inventory
Document the storage and use of the following materials:
a. Concrete
b. Detergents
c. Paints (enamel and latex)
d. Cleaning solvents
e. Pesticides
f. Wood scraps
g. Fertilizers
h. Petroleum based products
2. Good housekeeping practices
a. Store only enough product required to do the job.
b. All materials shall be stored in a neat, orderly manner in their original labeled containers
and covered.
c. Substances shall not be mixed.
d. When possible, all of a product shall be used up prior to disposal of the container.
e. Manufacturers’ instructions for disposal shall be strictly adhered to.
f. The site foreman shall designate someone to inspect all BMPs daily.
3. Waste management practices
a. All waste materials shall be collected and stored in securely lidded dumpsters in a location
that does not drain to a waterbody.
b. Waste materials shall be salvaged and/or recycled whenever possible.
c. The dumpsters shall be emptied a minimum of twice per week, or more if necessary. The
licensed trash hauler is responsible for cleaning out dumpsters.
Effective February 2019
Source: Symbol: Detail No.
Standard Detail & Specifications
Construction Site Waste Mgt &
Spill Control
Notes (cont.)
d. Trash shall be disposed of in accordance with all applicable Delaware laws.
e. Trash cans shall be placed at all lunch spots and littering is strictly prohibited. Recycle bins
shall be placed near the construction trailer.
f. If fertilizer bags can not be stored in a weather-proof location, they shall be kept on a pallet
and covered with plastic sheeting which is overlapped and anchored.
4. Equipment maintenance practices
a. If possible, equipment should be taken to off-site commercial facilities for washing and
maintenance.
b. If performed on-site, vehicles shall be washed with high-pressure water spray without
detergents in an area contained by an impervious berm.
c. Drip pans shall be used for all equipment maintenance.
d.
Equipment shall be inspected for leaks on a daily basis.
e. Washout from concrete trucks shall be disposed of in a temporary pit for hardening and
proper disposal.
f. Fuel nozzles shall be equipped with automatic shut-off valves.
g. All used products such as oil, antifreeze, solvents and tires shall be disposed of in
accordance with manufacturers’ recommendations and local, state and federal laws and
regulations.
5. Spill prevention practices
a. Potential spill areas shall be identified and contained in covered areas with no connection
to the storm drain system.
b. Warning signs shall be posted in hazardous material storage areas.
c. Preventive maintenance shall be performed on all tanks, valves, pumps, pipes and other
equipment as necessary.
d. Low or non-toxic substances shall be prioritized for use.
DE-ESC-3.6.1
Sheet 4 of 5
Adapted from USEPA
Pub. 840-B-92-002
Effective February 2019
Source: Symbol: Detail No.
Standard Detail & Specifications
Construction Site Waste Mgt &
Spill Control
Notes (cont.)
e. Contact information for reporting spills through the DNREC 24-Hour Toll Free Number shall
be prominently posted.
6. Education
a. Best management practices for construction site pollution control shall be a part of regular
progress meetings.
b. Information regarding waste management, equipment maintenance and spill prevention
shall be prominently posted in the construction trailer.
CONTACT INFORMATION
DNREC 24-Hour Toll Free Number 800-662-8802
DNREC Solid & Hazardous Waste Branch 302-739-9403
DE-ESC-3.6.1
Sheet 5 of 5
Adapted from USEPA
Pub. 840-B-92-002
Effective February 2019