Date: __________________________
General Description of Solar PV Array: __________________________________________________________________________
_______________________________________________________________________________________________________________
System Size (kW DC): ___________________________________________________________________________________________
Solar PV Mounting Information
Mounting Type (roof, pole, ground, other-specify): _________________________________________________________________
Mounting System Manufacturer: _________________________________________________________________________________
Product Name and Model #: _____________________________________________________________________________________
Building Information (For Roof-Mounted Systems Only)
Building Type (e.g. house, shed, barn, slab): _______________________________________________________________________
Building Height (in feet):_________________________________________________________________________________________
Is the building permitted? Yes No NA
If no, reason: ___________________________________________________________________________________________________
Electrical Description
Size (amps) and type (phase, voltage) of electrical service: __________________________________________________________
Amperage of main breaker: _____________ Will the value of main breaker change? Yes No To: __________________
Rated amperage of the bus bar in the main panel: __________________________________________________________________
Type of interconnection (e.g. breaker-load side, supply-side interconnect): ____________________________________________
Electrical panel location: ________________________________________________________________________________________
If load side interconnect, will solar intertie into a subpanel? Yes No
If yes, rated amperage of the subpanel bus bar? ___________ Value of breaker protecting subpanel bus bar? _____________
Attachments for application (See instructions on the next page. Example Attachments are available for download
at www.energizect.com/sunrisene)
1. Additional Subcontractors and Information
2. One-Line Electrical Drawing
3. One-Line Site Plan Drawing
4. Attachment Details (Line Drawing)*
5. Solar PV Module Specication Sheets From Manufacturer
6. Inverter Specication Sheets From Manufacturer
7. Pole or Ground Mount Information (if applicable)*
8. Structural Evaluation (if required by municipality). See page 3 for documentation requirements.
9. Additional Information for Large Solar PV Systems (as Specied by the Municipality)
* NOTE: Applicants should submit either Attachment 4 for roof-mounted systems OR Attachment 7 for pole/ground-
mounted systems, not both.
CT Standardized Solar PV Permit Application Supplement
Please ll in the following information and submit ALL applicable attachments.
Permit # [For Jurisdiction Use]: _________________
PAGE 1 OF 3
Version 8.1.2014
Each Attachment—Subcontractor List and
Drawings —Must Include:
• Date
• Property Owner
– Name
– Address
– Contact phone number
• Installation Company
– Name of company and contact person
– Address
– Contact phone number
Drawing number and Revision number or other control
method
• Drawing designer
Attachment 1. Additional Subcontractor List
(If Needed, as per Permit Application)
Attachment 2. One-Line Electrical Drawing
Must Show:
Size of electrical service
– Size of Main Breaker
– Size of Bus Bar (If Known)
Type of electrical service
If interconnection point is a subpanel
– Size of Subpanel Main Breaker
– Size of Subpanel Bus Bar (If Known)
Nominal power of solar system (Watts)
DC Capacity: Nameplate “STC” Value of all
panels, watts
– AC Capacity: Total AC capacity of Inverters, watts
Batteries (If Present): Type, Quantity, Nominal
Voltage, Capacity kWh
– H
2
mitigation methods (If Necessary)
(Attachment 2 continued)
Interconnection method
– Size of overcurrent protection
Number, type and electrical conguration of solar
panels
Number and type of Inverters
Values for source stickers: NEC 690.53; NEC 690.54
(Encouraged, Not Required)
Wiring methods
– Wire Type(s), Size
– Conduit Type(s), Size
Solar metering (If Appropriate)
Electrical current contribution from all PV sources
Electrical grounding details: Wire Type, Size, GEC
Attachment 3. One-Line Site Plan Drawing Must Show:
Location of solar panels
Location of Inverters and major equipment
Location of roof obstructions (Vents, Chimneys, etc.)
Location of Main Breaker Panel
Location of Utility Meter
Location of AC disconnect
Location of batteries and/or charge controllers (If
Appropriate)
Location of solar metering (If Appropriate)
Planned conduit path (Encouraged, Not Required)
Gross dimensions of structure (If Appropriate)
Approximate layout of building or other structure
(If Appropriate)
Property lines, zoning, and setback considerations
(If Appropriate)
Trenching details: Location, Depth and Length of
Trench (If Appropriate)
A notation indicating scale —or not to scale
(Both are Acceptable)
Instructions for ATTACHMENTS to the Connecticut
Standardized Solar PV Permit Application
Please Complete the Application Form (page 1) and provide all applicable Attachments based on the
below instructions for Attachments 1-8. Attachment 8 is a Structural Evaluation to be completed if required by the
municipality. Additional information required by a municipality for large solar PV systems can be submitted as a 9
th
Attachment. Example Attachments (e.g. sample drawings) can be found at www.energizect.com/sunrisene.
PAGE 2 OF 3
Version 8.1.2014
Attachment 4. Attachment Details for Roof-Mounted
Systems (Line Drawing) Must Show:*
Racking System
– Manufacturer of racking structure
– Model
Type
Flashing description
Fastener detail
Type of fasteners, e.g. Lag Screws, Seam Clamps,
Ballast
If Lag Screws include:
(1) Type (e.g. Zinc, Stainless steel)
(2) Size of Lag
(3) Depth of Thread Penetration
(4) Type of Sealant (e.g. caulk)
Mitigation of Dissimilar Metals
– Describe how any dissimilar metals will be isolated
Attachment 5. Solar PV Module Specication Sheets
(provide PDF from manufacturer)
Attachment 6. Inverter Specication Sheets
(provide PDF from manufacturer)
Attachment 7. Pole Mount or Ground Mount
Information (if applicable):*
Racking system
Mounting specication sheets and details from
manufacturer (PDFs)
Manufacturer’s Pre-Engineered Document or PE
Stamp
Code Compliance Manual (If Requested by
Municipality)
One-way distance from the Solar PV system to the
interconnection point
Electrical grounding details
Height of solar PV system at maximum design tilt
Applicable zoning information if not shown on site
plan (e.g. setback from property line)
Attachment 8. Structural Evaluation (if required by
the municipality)
NOTE: If this Attachment is required by the
municipality it must be submitted in a format accepted
by the municipality (see two examples, listed below).
Installers should contact the municipality’s Building
Department to determine what documentation
will meet the municipality’s Structural Evaluation
requirements.
Two potentially acceptable formats are:
1. Structural Review Worksheet (available at www.
energizect.com/sunrisene). This worksheet can
be used by an installer to meet the Structural
Evaluation requirements of a municipal Building
Department if the department specically
authorizes its use for that purpose.
OR
2. Proof of a Structural Review performed by a
Registered Design Professional (e.g. Professional
Engineer).
Attachment 9. Additional information required for
larger solar PV systems
This Standardized Solar PV Permit Application
Supplement can also be used to permit larger
systems. If a municipality requires additional
information to permit larger systems, they should
specify the information needed as a 9
th
attachment to
the application.
Instructions for ATTACHMENTS to the Connecticut
Standardized Solar PV Permit Application
* NOTE: Applicants should submit either Attachment 4 for roof-mounted systems OR Attachment 7 for pole/ground-
mounted systems, not both.
PAGE 3 OF 3
Version 8.1.2014