L40U 09/17 page 3 of 4 philips.com/luminaires
L40U L40 LED post top
Urban
Specications
Housing
Cupola: Decorative cast 356 aluminum
photocell housing, c/w a window, mechanically
mounted on hood.
Hood: In a square tapered shape, the hood is
made of a one-piece die cast injection molded
A360 aluminium. Mechanically assembled to
the guard.
Guard: In a square tapered shape, the guard is
made of one-piece die cast injection molded
A360 aluminium.
Access-mechanism
Two integrated hinges on the hood with a
stopper and a latch shall oer a tool-free
access to the inside of the luminaire. An
embedded memory-retentive gasket shall
ensure weatherproong.
Light engine
LEDgine composed of 5 main components:
Heat Sink / Lens / LED lamp / Driver /
Optical System. Electrical components are
RoHS compliant.
LED engine
Composed of high-performance white LEDs.
Color temperature as per ANSI/NEMA bin
Neutral White, 4000 Kelvin nominal (3985K
+/- 275K or 3710K to 4260K) or Warm white,
3000 Kelvin nominal (3045K +/- 175K or 2870K
to 3220K), CRI 70 Min. 75 Typical.
Globe/Panels
ACDR-C: Made of one-piece seamless
injection-molded clear impact-resistant
(DR) acrylic. The globe is assembled on the
access-mechanism.
PC-C: Made of one-piece seamless injection-
molded clear polycarbonate. The globe is
assembled on the access-mechanism.
Heat sink
Made of cast aluminum optimizing the LEDs
eciency and life. Product does not use any
cooling device with moving parts (only passive
cooling device).
Optical system
Composed of high performance optical grade
PMMA acrylic refractor lenses to achieve
desired distribution optimized to get maximum
spacing, target lumens and a superior lighting
uniformity. Optical system is rated IP66.
Performance shall be tested per LM 63, LM 79
and TM 15 (IESNA) certifying its photometric
performance. Street side indicated.
LE2 - Type II (ASYM) LE3 - Type III (ASYM)
LE4 - Type IV (ASYM) LE5 - Type V (SYMM)
Driver
Driver comes standard with dimming
compatible 0-10V. High power factor of 90%
minimum. Electronic driver, operating range
50/60 Hz. Auto adjusting universal voltage input
from 120 to 277 or 347 to 480 VAC rated for both
application
line to line or line to neutral, Class I,
THD of 20% max. Maximum ambient operating
temperature
from 40°F (40°C) to 130°F (55°C).
Certied
in compliance to UL1310 cULus
requirement. Dry
and damp location.
Assembled on a unitized
removable tray with
Tyco quick disconnect plug
resisting to 221°F
(105°C). The current
supplying the LEDs will be
reduced by the driver
if the driver experiences
internal overheating as a protection to the
LEDs and the electrical components. Output is
protected from short circuits, voltage overload
and current overload. Automatic recovery
after correction. Standard built in driver surge
protection of 2.5kV (min).
Driver options
AST: Pre-set driver for progressive start-up of the
LED module(s) to optimize energy management
and enhance visual comfort at start-up.
CLO: Pre-set driver to manage the lumen
depreciation by adjusting the power given to
the LEDs oering the same lighting intensity
during the entire lifespan of the LED module.
OTL: Pre-set driver to signal end of life of the
LED module(s) for better xture management.
DMG: Dimmable driver 0-10V.
CDMG: Dynadimmer standard dimming
functionalities including pre-programmed
scenarios to suit many applications and needs
from safety to maximum energy savings.
* Contact factory for DALI options.
Order
Code
Dimming
Scenario Duration Level
CDMGS25 Safety 4 hours 25%
CDMGS50 Safety 4 hours 50%
CDMGS75 Safety 4 hours 75%
CDMGM25 Median 6 hours 25%
CDMGM50 Median 6 hours 50%
CDMGM75 Median 6 hours 75%
CDMGE25 Economy 8 hours 25%
CDMGE50 Economy 8 hours 50%
CDMGE75 Economy 8 hours 75%
Fitter
L40U uses the SFR
Cast 356 aluminum c/w 4 set
screws 3/8-16 UNC. Slip-ts on
a 4" (102mm) outside diameter
by 4" (102mm) long tenon.
Surge protector
Surge protector tested in accordance with
ANSI/IEEE C62.45 per ANSI/IEEE C62.41.2
Scenario I Category C High Exposure
10kV/10kA waveforms for Line Ground,
Line Neutral and Neutral Ground, and in
accordance with U.S. DOE (Department of
Energy) MSSLC (Municipal Solid State Street
Lighting Consortium) model specication for
LED roadway luminaires electrical immunity
requirements for High Test Level 10kV / 10kA.
SP2 20kV/20kA optional.
Luminaire options
HS
House
side shield
SP2 20kV/20kA integral
surge protector (optional)
TN2.875C
2-7/8'' dia.
tenon adapter
TN3
3'' dia.
tenon adapter
TN3.5
3-1/2'' dia.
tenon adapter
CHM
Etched Glass
Chimney
RC
Receptacle 3-pins standard
(If a 5 or 7 pin is required
contact the factory)
PH8 (allows a 90° rotation)
Photoelectric Cell, Twist-lock
Type complete with receptacle.
PH9
Shorting cap, Twist-lock Type
complete with receptacle.
PHXL (allows a 90° rotation)
Extended life photoelectric
cell, Twist-lock Type complete
with receptacle.