Permit Number:
Date:
New Home
Used Home
Installer : License # Home installed to the Manufacturer's Installation Manual
Home is installed in accordance with Rule 15-C
Address of home
being installed
Single wide Wind Zone II Wind Zone III
Double wide Installation Decal #
Manufacturer
Length x width
Triple/Quad Serial #
NOTE: if home is a single wide fill out one half of the blocking plan
if home is a triple or quad wide sketch in remainder of home
I understand Lateral Arm Systems cannot be used on any home (new or used)
where the sidewall ties exceed 5 ft 4 in.
Installer's initials
Typical pier spacing
2'
Show locations of Longitudinal and Lateral Systems
(use dark lines to show these locations)
*
interpolated from Rule 15C-1 pier spacing table.
I-beam pier pad size
Perimeter pier pad size
Other pier pad sizes
(required by the mfg.)
Draw the approximate locations of marriage
wall openings 4 foot or greater. Use this
symbol to show the piers.
List all marriage wall openings greater than 4 foot
and their pier pad sizes below.
Opening Pier pad size
4 ft _______ 5 ft ________
within 2' of end of home _____
spaced at 5' 4" oc ______
Number
Longitudinal Stabilizing Device (LSD) Sidewall
Manufacturer ______________________________ Longitudinal
Longitudinal Stabilizing Device w/ Lateral Arms Marriage wall
Manufacturer ______________________________ Shearwall
Department of Growth Management Page 1 of 2 BF27 MH Permit Worksheet
Building Division
Revised November 04, 2010
3500 psf
8'
8'
8'
8'
3000 psf
8'
8'
8'
8'
4' 6"
2500 psf
7' 6"
8'
2000 psf
6'
8'
26 x 26
17 x 22
16 x 16
8'
8'
8'
8'
8'
676
24 x 24
576
256
16 x 18
288
374
13 1/4 x 26 1/4
348
18.5 x 18.5
342
16 x 22.5
360
17 1/2 x 25 1/2
446
20 x 20
400
17 3/16 x 25 3/16
441
Pad Size
Sq In
7'
8'
8'
POPULAR PAD SIZES
8'
8'
8'
8'
PIER SPACING TABLE FOR USED HOMES
1500 psf
1000 psf
3'
4'
5'
6'
7'
24" X 24"
(576)*
26" x 26"
(676)
Load
bearing
capacity
Footer
size
(sq in)
16" x 16"
(256)
18 1/2" x 18
1/2" (342)
20" x 20"
(400)
longitudinal
lateral
PIER PAD SIZES
ANCHORS
FRAME TIES
OTHER TIES
TIEDOWN COMPONENTS
marriage wall piers within 2' of end of home per Rule 15C
Mobile Home Permit Worksheet
Permit Number: Date:
Debris and organic material removed ______________.
The pocket penetrometer tests are rounded down to _________ psf Water drainage: Natural ______ Swale ______ Pad ______ Other ________.
or check here to declare 1000 lb. soil ______ without testing.
X X X
Floor: Type Fastener: ________ Length: ______ Spacing: ___________
Walls:
Type Fastener: ________ Length: ______ Spacing: ___________
Roof: Type Fastener: ________ Length: ______ Spacing: ___________
For used homes a min. 30 gauge, 8" wide, galvanized metal strip
1. Test the perimeter of the home at 6 locations. will be centered over the peak of the roof and fastened with galv.
roofing nails at 2" on center on both sides of the centerline.
2. Take the reading at the depth of the footer.
3. Using 500 lb. increments, take the lowest
reading and round down to that increment. I understand a properly installed gasket is a requirement of all new and used
homes and that condensation, mold, meldew and buckled marriage walls are
a result of a poorly installed or no gasket being installed. I understand a strip
X X X
of tape will not serve as a gasket.
Installer's initials ________________
Type gasket _______________ Installed:
Pg. _________ Between Floors Yes _____________
The results of the torque probe test is __________ inch pounds or check Between Walls Yes _____________
here if you are declaring 5' anchors without testing ______. A test Bottom of ridgebeam Yes _________
showing 275 inch pounds or less will require 5 foot anchors.
Note:
A state approved lateral arm system is being used and 4 ft.
anchors are allowed at the sidewall locations. I understand 5 ft
The bottomboard will be repaired and/or taped. Yes _______. Pg. _______
anchors are required at all centerline tie points where the torque test Siding on units is installed to manufacturer's specifications. Yes ______
reading is 275 or less and where the mobile home manufacturer may Fireplace chimney installed so as not to allow intrusion of rain water. Yes ____
requires anchors with 4000 lb holding capacity.
Installer's initials
ALL TESTS MUST BE PERFORMED BY A LICENSED INSTALLER
Skirting to be installed. Yes _______ No _______
Dryer vent installed outside of skirting. Yes ______ N/A _______
Installer Name
Range downflow vent installed outside of skirting. Yes _______ N/A _______
Drain lines supported at 4 foot intervals. Yes _______
Date Tested Electrical crossovers protected. Yes _______
Other :
Connect electrical conductors between multi-wide units, but not to the main power
source. This includes the bonding wire between mult-wide units. Pg. ________
Connect all sewer drains to an existing sewer tap or septic tank. Pg. _______
Connect all potable water supply piping to an existing water meter, water tap, or other
Installer Signature _________________________________ Date _______
independent water supply systems. Pg. __________
Department of Growth Management Page 2 of 2 BF27 MH Permit Worksheet
Building Division
Revised September 28, 2010
Plumbing
Site Preparation
Fastening multi wide units
Gasket (weatherproofing requirement)
Weatherproofing
Electrical
Miscellaneous
POCKET PENETROMETER TEST
POCKET PENETROMETER TESTING METHOD
TORQUE PROBE TEST
Installer verifies all information given with this permit worksheet
is accurate and true based on the
manufacturer's installation instructions and or Rule 15C-1 & 2
Mobile Home Permit Worksheet