-2-
CORRECTION LIST (cont’d.)
No. DESCRIPTION
Code
Section
-3-
NOTE: Entries to this Plan Review Record that require a field check or inspection of the installation must be coordinated with the inspection phase (R109) of the project.
BUILDING PLANNING (Chapter 3)
DESIGN CRITERIA [Table R301.2(1)]
Floor live load
(Table R301.5)
________________psf
Roof live load
(Table R301.6)
_________________psf
Ground snow load _________________________psf
Basic wind speed ________________________ mph
Wind exposure category
(R301.2.1.4)
_____ _______
High wind design criteria applicable
(R301.2.1.1)
_____________________________
Seismic design category (SDC)
[Figure R301.2(2)]
________________________
SDC C&D provisions
(R301.2.2)
________________
Weathering_________________________________
Frost line depth______________________________
Termite area ________________________________
Decay area_________________________________
Winter design temperature_____________________
Ice barrier underlayment required _______________
Flood hazards ______________________________
FIRE-RESISTANT CONSTRUCTION (R302)
_________Exterior walls
[R302.1, Tables R302.1(1) and R302.1(2)]
_________Townhouse separation
(R302.2)
_________ Continuity and structural independence
(R302.2.1, R302.2.4)
_________ Parapets and construction
(R302.2.2, R302.2.3)
_________ Two-family dwelling separation
(R302.3)
_________ Dwelling unit penetrations
(R302.4)
_________ Dwelling/garage opening/penetration protec-
tion
(R302.5)
_________ Dwelling/garage fire separation
(R302.6)
_________ Under-stair protection
(R302.7)
_________ Wall and ceiling finishes
(R302.9)
_________ Flame spread index
(R302.9.1)
_________ Smoke-developed index
(R302.9.2)
_________ Testing
(R302.9.3, R302.9.4)
_________ Insulation
(R302.10)
_________ Flame spread/smoke-developed
(R302.10.1, R302.10.2)
_________ Cellulose loose-fill and exposed attic
insulation
(R302.10.3, R302.10.4)
_________ Testing
(R302.10.5)
_________ Fireblocking
(R302.11)
_________ Draftstopping
(R302.12)
_________ Combustible insulation clearance
(R302.13)
_________Required heating
(R303.9)
SANITATION (R306 and R307)
_________Water closet
_________Lavatory
_________Tub or shower
_________Kitchen area with sink
_________Sanitary sewer
(Chapter 30)
_________Private disposal
(Appendix I)
GLAZING (R308)
_________ Identification
(R308.1)
_________ Louvered windows or jalousies
(R308.2)
_________ Human impact loads/hazardous locations
(R308.3, R308.4)
_________ Skylights and sloped glazing
(R308.6)
ROOM PLANNING REQUIREMENTS (R303 through R305)
* See Sections R303.1 & R303.3 for mechanical ventilation and artificial light and R303.4 for required whole-house mechanical ventilation.
† 6-8 min. at plumbing fixtures and for non-habitable basements.
Use Area (ft
2
) Width Ceiling height
Natural light* Natural ventilation*
Living
Dining
Kitchen
Bedroom
Bathroom
120
70
N.A.
70
N.A.
7-0
7-0
N.A.
7-0
N.A
7–0
7–0
7–0
7–0
7–0
8% floor area
8% floor area
8% floor area
8% floor area
3 square feet
4% floor area
4% floor area
4% floor area
4% floor area
1
1
/
2
square feet
-4-
BUILDING PLANNING (cont'd.)
GARAGES AND CARPORTS (R309)
_________Floor surface noncombustible; sloped floor
(R309.1)
_________Carport: open two sides; noncombustible
floors; sloped floor
(R309.2)
_________Automatic garage door opener
(R309.4)
_________Fire sprinklers
(R309.5)
EMERGENCY ESCAPE AND RESCUE OPENINGS
(R310)
_________Where required
(R310.1)
_________Areas, height, width, operations
(R310.1.1 - R310.1.4)
_________Window wells
(R310.2)
_________Bars, grilles, covers and screens
(R310.4)
_________Under decks and porches
(R310.5)
MEANS OF EGRESS (R311)
_________General
(R311.1)
_________Egress door
(R311.2)
_________Landings at exterior doors
(R311.3 - R311.3.3)
_________Vertical egress
(R311.4)
_________Construction and attachment
(R311.5)
_________Hallways
(R311.6)
_________Stairway width, headroom, vertical rise,
walkline
(R311.7.1 - R311.7.4)
_________Stairway treads, risers profiles
(R311.7.5 - R311.7.5.4)
_________Stairway landings and walking surfaces
(R311.7.6, R311.7.7)
_________Handrails required
(R311.7.8)
_________Handrail height, continuity, grip-size
(R311.7.8.1 - R311.7.8.4)
_________Stairway illumination
(R303.6, R311.7.9)
_________Special stairways
(R311.7.10)
_________Ramp slope, landings, handrails
(R311.8)
GUARDS AND WINDOW PROTECTION (R312)
_________Required for open-sided surfaces, stairs,
ramps and landings > 30 above floor/
grade
(R312.1.1)
_________Height - 36
(R312.1.2)
_________ Opening limitations
(R312.1.3)
_________ Window fall protection
(R312.2)
AUTOMATIC FIRE SPRINKLER SYSTEMS (R313)
_________ Townhouses
(R313.1)
_________ One- and two-family dwellings
(R313.2)
SMOKE ALARMS (R314)
_________ Referenced standards
(R314.1, R314.2)
_________ Location and interconnection
(R314.3, R314.5)
_________ Power source
(R314.4)
CARBON MONOXIDE ALARMS (R315)
_________ New construction
(R315.1, R315.2)
_________ Existing construction
(R315.3)
_________ Referenced standard
(R315.4)
FOAM PLASTIC (R302.8, R316)
_________ Labeling
(R316.2)
_________ Surface burning, thermal barrier, specific
approval
(R316.3 - R316.7)
DECAY AND TERMITE PROTECTION (R317 and R318)
_________ Protection required
(Table R301.2(1), R317.1, R318.1)
_________ Quality mark
(R317.2 and R318.1.1)
SITE ADDRESS (R319)
_________ Address numbers
(R319.1)
ACCESSIBILITY (R320)
_________ Type B dwelling units applicable
(R320.1)
ELEVATORS/PLATFORM LIFTS (R321)
_________ Referenced standards
(R321.1 - R321.3)
FLOOD-RESISTANT CONSTRUCTION (R322)
_________ General
(R322.1)
_________ Hazard area and requirements
(R301.2.4, R309.3, R322.2, R322.3)
_________ Design professional
(R322.3.6)
STORM SHELTERS (R323)
_________ General/referenced standard
(R323.1)
-5-
FOUNDATIONS (Chapter 4)
MATERIALS (R402)
_________Wood foundations
(R402.1)
_________Concrete, compressive strength
(R402.2)
FOOTINGS (R403)
_________Soil bearing value
(R401.4, R403.1)
_________Footing width
(Table R403.1)
_________Footing edge thickness = 6 minimum; footing
projection = 2 minimum, but footing
thickness
(R403.1.1)
_________Footings in SDC C or D
(R403.1.2, R403.1.3
and R403.1.6.1)
_________Depth below (outside) grade = 12 minimum;
but below frost line except for frost pro-
tected footings.
(R403.1.4, R403.1.4.1 and
R403.1.4.2)
_________Sill plate bolting in concrete/masonry =
1
/
2
di-
ameter bolts, within 12 but not less than 7
bolt diameters from ends, 7 embedment
(R403.1.6)
_________Footings adjacent to slopes
(R403.1.7)
_________Frost protected shallow foundations
(R403.3)
_________Footings for precast concrete foundation
(R403.4)
FOUNDATION/RETAINING WALLS (R404 - R406)
_________Masonry foundation walls
(R404.1.1)
_________Wall height, unbalanced backfill, nominal
thickness
[Tables R404.1.1(1) -
R404.1.1(4), R404.1.5.1]
_________Reinforcement size and spacing
[Tables R404.1.1(2) - R404.1.1(4)]
_________ Concrete foundation walls
(R404.1.2)
_________ Wall height, unbalanced backfill, nominal
thickness
[Tables R404.1.2(1) -
R404.1.2(8), R404.1.5.2]
_________ Horizontal and vertical reinforcement size and
spacing
[Tables R404.1.2(1) -
R404.1.2(8), R404.1.2.2, R404.1.2.3.7]
_________ Stay-in-place forms
(R404.1.2.3.6.1)
_________ SDC C and D provisions
(R404.1.2.4, R404.1.4)
_________ Height above finished grade
(R404.1.6)
_________ Sill plate size
(R404.3)
_________ Precast concrete foundation walls
(R404.5)
_________ Drains required if habitable or usable spaces
are below grade*
(R405)
_________ Soil class
(Table R405.1)
_________ Dampproofing if basements are below grade*
(R406.1)
_________ Waterproofing if high water table*
(R406.2)
* If uninhabitable, see Under-Floor Space
(R408)
COLUMNS (R407)
_________ Protection from decay or corrosion
(R407.1 and R407.2)
_________ Structural requirements
(R407.3)
_________ Anchorage
(R407.3)
_________ Wood columns (minimum 4 square)
(R407.3)
_________ Steel columns (minimum 3 diameter, Sched-
ule 40 pipe)
(R407.3)
TABLE R403.1
MINIMUM WIDTH OF CONCRETE, PRECAST OR MASONRY FOOTINGS (inches)
a
For SI: 1 inch = 25.4 mm, 1 pound per square foot = 0.0479 kPa.
a. Where minimum footing width is 12 inches, a single wythe of solid or fully grouted 12–inch nominal concrete masonry units is permitted.
LOAD-BEARING VALUE OF SOIL (psf)
1,500 2,000 3,000 4,000
Conventional light–frame construction
1-story 12 12 12 12
2-story 15 12 12 12
3-story 23 17 12 12
4-inch brick veneer over light frame or 8-inch hollow concrete masonry
1-story 12 12 12 12
2-story 21 16 12 12
3-story 32 24 16 12
8-inch solid or fully grouted masonry
1-story 16 12 12 12
2-story 29 21 14 12
3-story 42 32 21 16
-6-
FOUNDATIONS (cont'd.)
UNDER-FLOOR SPACE (R408)
_________ Ventilation
(R408.1 and R408.2)
_________ Unvented crawl space
(R408.3)
_________ Access
(R408.4)
_________ Removal of debris
(R408.5)
_________ Finished grade
(R408.6)
_________ Flood resistance
(R408.7)
FLOORS (Chapter 5)
WOOD JOISTS AND GIRDERS (R502)
_________Species and grade
(R502.1)
_________Joists—Sleeping areas, LL = 30 psf
[Table R502.3.1(1)]
_________Joists—Nonsleeping areas, LL = 40 psf
[Table R502.3.1(2)]
_________Cantilevered joists
[Tables R502.3.3(1) and R502.3.3(2)]
_________Girder spans and header spans for exterior
bearing walls
[Table R502.5(1)]
_________Girder spans and header spans for interior
bearing walls
[Table R502.5(2)]
_________Joists under bearing partitions
(R502.4)
_________Bearing (1.5 minimum on wood or metal; 3
on masonry or concrete) and lapped joists
(3)
(R502.6, R502.6.1)
_________Lateral restraint and bridging
(R502.7, R502.7.1)
_________Drilling and notching
(R502.8)
_________Fastening
(R502.9)
_________Framing of openings
(R502.10)
_________Wood trusses
(R502.11)
_________Draftstopping
(R502.12)
LUMBER FLOOR SHEATHING (R503.1)
_________Allowable span
(Table R503.1)
_________End joints
(R503.1.1)
WOOD STRUCTURAL PANEL SHEATHING (R503.2)
_________Grade
(R503.2.1)
_________Thickness
(R503.2.1)
_________Allowable spans
[Tables R503.2.1.1(1) and R503.2.1.1(2)]
_________Installation
[Table 602.3(1)]
PARTICLEBOARD UNDERLAYMENT (R503.3)
_________ Grade
(R503.3.1)
_________ Thickness
(R503.3.2)
_________ Installation
[Table R602.3(1)]
TREATED-WOOD FLOORS (ON GROUND) (R504)
_________ Base course: 4 thick with maximum
3
/
4
gravel or
1
/
2
crushed stone
(R504.2.1)
_________ Moisture barrier: placed over base course
(R504.2.2)
_________ Materials
(R504.3)
STEEL FLOOR FRAMING (R505)
_________ Cold-formed steel; applicability limits;
in-line framing
(R505.1)
_________ Structural framing
(R505.2)
_________ Material
(R505.2.1)
_________ Identification
(R505.2.2)
_________ Corrosion protection
(R505.2.3)
_________ Fastening
(R505.2.4)
_________ Floor construction
(R505.3)
CONCRETE FLOORS (ON GROUND) (R506)
_________ Thickness: 3
1
/
2
minimum; Concrete strength
(R506.1)
_________ Support: prepared subgrade; maximum earth
fill = 8; maximum sand or gravel fill = 24
(R506.2.1)
_________ Base course: 4 graded with 2 maximum
aggregate
(R506.2.2)
_________ Vapor retarder
(R506.2.3)
_________ Reinforcement support
(R506.2.4)
DECKS (R507)
_________ Support, attachment
(R507.1 - R507.2.3)
_________ Wood/plastic materials
(R507.3)
-7-
WALL CONSTRUCTION (Chapter 6)
GENERAL (R601)
_________Design
(R601.2)
_________Component and cladding wind loads
[Table R301.2(2)]
WOOD CONSTRUCTION (R602)
_________Construction
[Figures R602.3(1) and R602.3(2)]
_________Stud grade
(R602.2)
_________Exterior walls
(R602.3)
_________Stud spacing
[R602.3.1, Table R602.3(5)]
_________Interior load-bearing walls
(R602.4)
_________Interior nonbearing walls: 2 × 3 at 24 o.c.
or 2 × 4 flat at 16 o.c.
(R602.5)
_________Drilling and notching—studs
(R602.6)
_________Drilling and notching—top plate
(R602.6.1)
_________Headers
[Tables R502.5(1), R502.5(2),
R602.7.2 and Figure R602.7.2]
_________Fireblocking
(R602.8, R302.11)
_________Cripple walls
(R602.9)
_________Wall bracing, lines, panels
(R602.10.1, R602.10.2)
_________Required length of bracing, method
[R602.10.3, R602.10.4, Tables
R602.10.3(1) and R602.10.3(3)]
_________Minimum length, connections, support, joints,
cripple walls
(R602.10.5 - R602.10.11)
_________Wall anchorage (SDC C and D)
(R602.11)
_________Simplified wall bracing
(R602.12)
STEEL WALL FRAMING (R603)
_________General
(R603.1)
_________Structural framing
(R603.2)
_________Material
(R603.2.1)
_________Identification
(R603.2.2)
_________ Corrosion protection
(R603.2.3)
_________ Fastening
(R603.2.4)
_________ Wall construction
(R603.3 - R603.5)
_________ Headers
(R603.6)
_________ Studs, tracks and structural sheathing
(R603.7 - R603.9)
SHEATHING (R604 and R605)
_________ Wood structural panels
(R604)
_________ Particleboard
(R605)
MASONRY CONSTRUCTION (R606 - R610)
_________ General design
(R606)
_________ SDC C and D
(R606.12)
_________ Unit masonry
(R607)
_________ Multiple-wythe masonry
(R608)
_________ Grouted masonry
(R609)
_________ Glass unit masonry
(R610)
EXTERIOR CONCRETE WALL CONSTRUCTION (R611)
_________ Applicability
(R611.2)
_________ Concrete wall systems
(R611.3)
_________ Stay-in-place forms
(R611.4)
_________ Materials, construction details
(R611.5 - R611.10)
EXTERIOR WINDOWS & DOORS
(R612)
_________ General; performance; testing and labeling
(R612)
STRUCTURAL INSULATED PANEL WALL
CONSTRUCTION (R613)
_________ Applicability
(R613.2)
_________ Materials
(R613.3)
_________ Wall panels, construction details
(R613.4 - R613.10)
-8-
WALL COVERING (Chapter 7)
INTERIOR WALL COVERING (R702)
_________Plaster material
(R702.2)
_________Plaster support
(R702.2.3)
_________Gypsum board material
(R702.3.1)
_________Gypsum board support, application and fas-
tening
(R702.3.2 - R702.3.8)
_________Ceramic tile
(R702.4)
_________Other finishes
(R702.5 and R702.6)
_________Vapor retarders
(R702.7)
EXTERIOR WALL COVERING (R703)
_________Water-resistive barrier
(R703.2)
_________Wood siding
(R703.3)
_________Attachment and minimum thickness
(Table R703.4)
_________ Wood shakes and shingles
(R703.5)
_________ Exterior plaster
(R703.6)
_________ Stone & masonry veneer
(R703.7 & Figure
R703.7)
; Steel angle lintels-4 minimum
bearing each end
(R703.7.3)
_________ Veneer ties: #9 U.S. gage wire or #22 U.S.
gage by
7
/
8
corrugated metal; horizontal
and vertical spacing; 2.67 square feet
maximum area supported (wind > 30 psf
and SDC C or D, maximum area = 2
square feet)
(R703.7.4.1)
_________ Flashing
(R703.7.5 and R703.8)
_________ Exterior insulation and finish systems
(R703.9)
_________ Fiber cement siding
(R703.10)
_________ Vinyl siding
(R703.11)
ROOF-CEILING CONSTRUCTION (Chapter 8)
GENERAL (R801)
_________Design
(R801.2 and R801.3)
_________Component and cladding wind loads
[Table R301.2(2)]
WOOD ROOF FRAMING (R802)
_________Fire-retardant-treated wood
(R802.1.3)
_________Framing details
(R802.3)
_________Rafter tie
(R802.3.1)
_________Collar ties (4 o.c., in upper third of attic)
(R802.3.1)
_________Purlins (2 × 4 at 4 o.c. minimum)
(Figure R802.5.1, R802.5.1)
_________Bearing
(R802.6)
_________Cutting and notching
(R802.7)
_________Engineered wood products
(R802.7.2)
_________Lateral support and bridging
(R802.8)
_________Framing of openings
(R802.9)
_________Wood trusses
(R802.10)
_________Roof tie-down
(R802.11)
CEILING JOISTS [Tables R802.4(1), R802.4(2)]
_________Without attic storage, LL = 10psf
_________With attic storage LL = 20psf
_________ Spacing
_________ Species and grade
_________ Span
_________ Size
RAFTERS [Tables R802.5.1(1) - R802.5.1(8)]
_________ Ground snow load/LL = 20psf
_________ Controlling design (LL or snow)
_________ Ceiling not attached/ceiling attached
_________ Spacing
_________ Species and grade
_________ Span
_________ Size
_________ H
C
/H
R
; Adjustment factor
ROOF SHEATHING (R803.2)
_________ Grade
_________ Thickness
_________ FRTW allowable stresses/grading
_________ Allowable spans
[Table R503.2.1.1(1)]
_________ Installation
(R803.2.3)
-9-
ROOF-CEILING CONSTRUCTION (cont'd.)
STEEL ROOF FRAMING (R804)
_________General
(R804.1)
_________Structural framing
(R804.2)
_________Material
(R804.2.1)
_________Identification
(R804.2.2)
_________Corrosion protection
(R804.2.3)
_________Fastening
(R804.2.4)
_________ Roof construction
(R804.3)
_________ Roof tie-down
(R804.3.9)
ROOF VENTILATION (R806)
_________ Ventilation requirements
(R806.1 - R806.5)
ATTIC ACCESS (R807)
_________ Access requirements
(807.1)
CHIMNEYS AND FIREPLACES (Chapter 10)
MASONRY FIREPLACES (R1001)
_________Construction
(Figure R1001.1 and Table R1001.1)
_________SDC D reinforcing/anchorage
(R1001.3 and R1001.4)
_________Firebox walls and dimensions
(R1001.5 and R1001.6)
_________Steel fireplace units
(R1001.5.1)
_________Lintel (noncombustible)
(R1001.7)
_________ Hearth extension
(R1001.9, R1001.10)
_________ Fireplace clearance
(R1001.11)
_________ Fireblocking
(R1001.12)
MASONRY CHIMNEYS (R1003)
_________ Construction
(Table R1001.1, R1003.2,
R1003.3, and Figure R1001.1)
_________ Corbeling
(R1003.5)
ROOF ASSEMBLIES (Chapter 9)
ROOF CLASSIFICATION (R902)
_________Roof covering materials
(R902.1)
WEATHER PROTECTION (R903)
_________Flashing
(R903.2)
_________Coping
(R903.3)
_________Roof drainage
(R903.4)
MATERIALS (R904)
_________Compatibility; specifications; physical charac-
teristics; identification
(R904.2 - R904.4)
REQUIREMENTS FOR ROOF COVERINGS (R905)
_________Asphalt shingles
(R905.2)
_________Clay and concrete tile
(R905.3)
_________Metal roof shingles
(R905.4)
_________Mineral-surfaced roll roofing
(R905.5)
_________Slate and slate-type shingles
(R905.6)
_________Wood shingles
(R905.7)
_________ Wood shakes
(R905.8)
_________ Built-up roofs
(R905.9)
_________ Metal roof panels
(R905.10)
_________ Modified bitumen roofing
(R905.11)
_________ Thermoset single-ply roofing
(R905.12)
_________ Thermoplastic single-ply roofing
(R905.13)
_________ Sprayed polyurethane foam roofing
(R905.14)
_________ Liquid-applied coatings
(R905.15)
_________ Photovoltaic shingles
(R905.16)
ROOF INSULATION (R906)
_________ General
(R906.1)
REROOFING (R907)
_________ Materials and methods
(R907.1)
_________ Structural support
(R907.2)
_________ Recover vs replace
(R907.3)
-10-
CHIMNEYS AND FIREPLACES (cont'd.)
_________Changes in dimension
(R1003.6)
_________Additional load
(R1003.8)
_________Termination
(R1003.9)
_________Spark arrestors
(R1003.9.2)
_________Wall thickness; 4
(R1003.10)
_________Flue lining - material/installation
(R1003.11 and R1003.12)
_________Multiple flues
(R1003.13)
_________Flue area (appliance)
(R1003.14)
_________Flue area (masonry fireplace)
(R1003.15)
_________Inlet
(R1003.16)
_________Cleanout opening
(R1003.17)
_________ Chimney clearance
(R1003.18)
_________ Fireblocking
(R1003.19)
_________ Chimney crickets
(R1003.20)
FACTORY-BUILT FIREPLACES (R1004)
_________ Listed and labeled
(R1004.1)
_________ Installation
(R1004.2)
FACTORY-BUILT CHIMNEYS (R1005)
_________ Listed and labeled
(R1005.1)
_________ Installation
(R1005.3 and R1005.4)
EXTERIOR AIR SUPPLY (R1006)
_________ Intake size
(R1006.2, R1006.4)
ENERGY EFFICIENCY (Chapter 11)
_________Compliance; information
(N1101.5, N1101.8)
_________Climate zone
(Table N1101.10)
_________Building thermal envelope
(N1102)
_________ Systems
(N1103)
_________ Electrical
(N1104)
_________ Simulated performance
(N1105)
MECHANICAL (Chapters 12-23)
_________Appliance labeling
(M1302, M1303)
_________Appliance access
(M1305, M1401)
_________Appliance installation
(M1307)
_________Heating and cooling equipment; load calcula-
tions
(Chapter 14)
_________Exhaust systems
(Chapter 15)
_________Duct systems
(Chapter 16)
_________Combustion air
(Chapter 17)
_________ Chimney and vent location and terminations
(Chapters 10 and 18)
_________ Special equipment
(Chapter 19)
_________ Boilers/water heaters
(Chapter 20)
_________ Hydronic piping
(Chapter 21)
_________ Special piping and storage systems
(Chapter 22)
_________ Solar systems
(Chapter 23)
_________ Penetrations of fire-resistance rated assem-
blies
(R302.4, R302.5)
FUEL GAS (Chapter 24)
_________Application
(G2401.1)
_________General regulations
(G2404)
_________Appliance location
(G2406)
_________Air requirements
(G2407)
_________Installation
(G2408)
_________ Clearances
(G2409)
_________ Electrical and electrical bonding
(G2410, G2411)
_________ Pipe sizing
(G2413)
_________ Piping materials
(G2414)
-11-
FUEL GAS (cont'd)
_________Piping installation
(G2415 and G2419)
_________Piping support
(G2418 and G2424)
_________Valves, controls, connections
(G2420, G2421 and G2422)
_________ Venting
(G2425 - G2429)
_________ Misc appliances
(G2423, G2430 - G2454)
PLUMBING (Chapters 25-33)
_________Water service location and depth
(P2603, P2604)
_________Sanitary and storm sewer location and depth
(P2603, P2604)
_________Piping support
(Table P2605.1)
_________Listed plastic materials
(P2609)
_________Plumbing fixtures
(Chapter 27)
_________Water heater size and location
(Chapter 28)
_________Water supply and distribution system design
and calculations
(Chapter 29)
_________Dwelling unit fire sprinkler systems
(P2904)
_________ NFPA 13D system
(P2904.1)
_________ Temperature rating
(P2904.2.1, P2904.2.2)
_________ Freezing protection
(P2904.2.3)
_________ Sprinkler coverage
(P2904.2.4)
_________ Piping materials
(P2904.3)
_________ Flow rates
(P2904.4.1, P2904.4.2)
_________ Water supply capacity
(P2904.5.2)
_________ Pipe sizing
(P2904.6)
_________ Drain, waste and vent pipe sizing and riser
diagram
(P3004, P3005, Chapter 31)
_________ Sumps and ejectors
(P3007)
_________ Backwater valves
(P3008)
_________ Fixture traps
(P3201)
_________ Storm drainage
(Chapter 33)
_________ Penetrations of fire-resistance rated assem-
blies
(R302.4, R302.5)
ELECTRICAL (Chapters 34-43)
_________Penetrations of fire-resistance rated assem-
blies
(E3402.2)
_________Listed and labeled materials
(E3403)
_________Service equipment and location
(E3405, E3601, E3606)
_________Service size and load calculations
(E3602)
_________Available fault current
(E3606)
_________System grounding
(E3607)
_________Required branch circuits
(E3703)
_________Feeder requirements and load calculations
(E3704)
_________ Wiring methods
(Chapter 38)
_________ Required lighting and receptacle outlets
(E3901, E3903)
_________ Ground-fault and arc-fault circuit-interrupter
protection
(E3902)
_________ Devices and lighting fixtures
(Chapter 40)
_________ Appliance installation
(Chapter 41)
_________ Swimming pools
(Chapter 42)
_________ Class 2 remote-control, signaling and power-
limited circuits (
Chapter 43)
MANUFACTURED HOUSING USED AS DWELLINGS (Appendix E)
_________Provisions adopted
(R102.5)
_________ Compliance with Appendix E verified
-12-
RADON CONTROL MEASURES (Appendix F)
_________Provisions adopted
(R102.5)
_________ Compliance with Appendix F verified
SWIMMING POOLS, SPAS AND HOT TUBS (Appendix G)
_________ Provisions adopted
(R102.5)
_________ Compliance with Appendix G verified
PATIO COVERS (Appendix H)
_________ Provisions adopted
(R102.5)
_________ Compliance with Appendix H verified
PRIVATE SEWAGE DISPOSAL (Appendix I)
_________Provisions adopted
(R102.5)
_________ Compliance with Appendix I verified
EXISTING BUILDINGS AND STRUCTURES (Appendix J)
_________Provisions adopted
(R102.5)
_________ Compliance with Appendix J verified
SOUND TRANSMISSION (Appendix K)
_________Provisions adopted
(R102.5)
_________ Compliance with Appendix K verified
HOME DAY CARE—R-3 OCCUPANCY (Appendix M)
_________Provisions adopted
(R102.5)
_________ Compliance with Appendix M verified
NOTES
AUTOMATIC VEHICULAR GATES (Appendix O)
_________Provisions adopted
(R102.5)
_________ Compliance with Appendix O verified